-800x600w.jpg)
-800x600w.jpg)
-800x600w.jpg)
-800x600w.jpg)
-800x600w.jpg)
-80x80w.jpg)
-80x80w.jpg)
-80x80w.jpg)
-80x80w.jpg)
-80x80w.jpg)
![]() | Approved Vendor to many US, Canada, and EU Universities |
![]() | International Shipping |
![]() | Customer References Available |
![]() | Training and Installation Options Available |
- Stock: In Stock
- Brand: Thermo Scientific
- Product Code: 68742
- Condition: Pre-Owned
For Sale Thermo Scientific Vanquish Flex Quaternary UHPLC System with Variable Wavelength and Fluorescence Detectors
- Fully Functional
- Serviced & in Stock
- Current Model
- Made in 2022-2023
- Good cosmetic condition
- Technical sales consultation available
- WARRANTY
- Includes remote instrument setup and training session
Here is what you will receive:
- Vanquish Quaternary Pump F w/ Static Mixer, volume: 350 uL p/n: VF-P20-A
- Vanquish Split Sampler FT p/n: VF-A10-A
- Vanquish Split Sampler Sample Racks 54 pos.x12 mm OD vials (≤ 1.5 mL) Qty.(3)
- Vanquish Column Compartment H p/n: VH-C10-A
- Vanquish Variable Wavelength Detector F p/n: VF-D40-A with Standard Bio flow cell (11 uL, 10 mm, 50Bar) p/n 6077.0200
- Vanquish Fluorescence Detector F, p/n: VF-D50-A with Standard Bio flow cell (8 uL,20Bar) p/n 6079.4230
- PC loaded with Chromeleon software v.7.3.1
- Solvents Rack
- Inter-communication cables
- Standard power cords
Vanquish Flex Quaternary UHPLC System Configuration:
Vanquish Fluorescence Detector F:
- Optical design: two monochromators with concave holographic gratings and elliptic mirrors for the highest efficiency in light transmission
- Light source: xenon flash lamp (15W)
- Number of photomultipliers: 1
- Wavelength range: Excitation: 220 nm - 630 nm/Emission: 220 nm - 650 nm
- Spectral bandwidth: Excitation: 20 nm/Emission: 20 nm
- Wavelength accuracy: ± 2 nm
- Wavelength repeatability: ± 0.2 nm
- Spectra scanning modes: Single spectrum scan modes: Excitation, Emission, Synchronous
- Number of channels: up to 4 channels
- Data collection rate: up to 200 Hz
- Wavelength switching time: <250 ms
- Emission filter: variable: 5 positions
- Flow Cell: standard flow cell, biocompatible (8 uL, 2 MPa, fused silica)
Vanquish Variable Wavelength Detector F:
- Optical design: UV/VIS/NIR photometer (tunable Czerny-Turner monochromator) with additional internal reference beam
- Light source: Deuterium lamp for UV and VIS; Tungsten lamp for VIS and NIR
- Wavelength range: 190–900 nm (with deuterium and tungsten lamp)
- Spectral bandwidth: typ. 6 nm at 254 nm
- Wavelength Accuracy: ± 1 nm
- Wavelength Repeatability: ± 0.1 nm
- Wavelength Calibration: Internal calibration with zero order of monochromator spectrum
- Wavelength Validation: Internal validation with holmium-oxide filter
- Signal channel: Up to 4 signal channels
- Data collection rate (single-channel): up to 250 Hz; (multi-channel) Up to 5 Hz
- Noise (single-channel): <±2.5 uAU at 254 nm
- Noise (multi-channel): <±10 uAU (typical <±7 uAU) at 254 nm and 280 nm
- Drift: <0.1 mAU/h at 254 nm
- Linearity: <5% at 2.5 AU (typical <3% at 2.5 AU
- Flow Cell: Standard Bio flow cell (11 uL, 10 mm, 50Bar)
Vanquish Quaternary Pump F:
- Operating Principle: serial dual-piston pump
- Flow Range: 0.001–8 mL/min, in 1 uL/min increments
- Pressure Range: 2–103 MPa; flow rate >5 mL/min, the pressure range decreases 80 MPa
- Compressibility Compensation: fully automated, independent of the composition of the mobile phase
- Flow Accuracy: ±0.1%
- Flow Precision: <0.05% RSD or <0.01 min SD, whichever is greater
- Pulsation typically: <1.0% or <0.2 MPa, whichever is greater
- Gradient Formation: low-pressure gradient proportioning
- Proportioning Accuracy: ±0.5% of full-scale
- Proportioning Precision: <0.15% SD
- Number of Solvent Lines: 4
- Mixer Volume: 350 uL static mixer
- Dwell Volume: 679 uL
- Solvent Degassing: built-in, 4 Channels
Vanquish Split Sampler FT:
- Injection units: 1
- Operating principle: split loop injection
- Pressure range: 2–103 MPa
- Injection volume range: 0.01–100 uL, min. Step = 0.01 uL
- Injection volume accuracy: typically ±0.5% for 10 uL water
- Injection volume precision: <0.25% area RSD for 1 uL (caffeine in water); typically <0.5% area RSD for 0.5 uL (caffeine in water)
- Injection linearity: r > 0.99999 (caffeine in water)
- Injection cycle time: down to 8s depending on separation conditions
- Minimum sample required: 2 uL at 1 uL injection volume
- Carryover (UV): <0.002% with caffeine (typically: <0.0004%)
- Needle wash (external): 1 solvent per injection unit, dip rinse and continuous rinse
- Sample compartment temperature range: 4–40 DegC (≥23 K below ambient at <80% RH)
- Sample temperature accuracy: -2 DegC/+4 DegC
- Sample temperature stability: ±1 DegC
- Sample capacity: 4 segments useable for sample racks or well plates with SBS footprint format; plus a capacity of 12 x 22.5 mm O.D. vials in the carousel
- Included sample racks: (3) x Sample Racks 54 pos.x12 mm OD vials (≤ 1.5 mL)
- Barcode reading: empty segment detection, rack/well plate verification, inventory management
Vanquish Column Compartment H:
- Operating Principle Column Chamber: still air and forced air
- Temperature Range: 5–120 DegC in 0.1 DegC increments (18K below ambient)
- Temperature Stability: ±0.05K
- Temperature Accuracy: ±0.5K (up to 80 DegC)
- Heating Performance: <15 min, 20–50 DegC, ±1K Typical: 5 min, 25–40 DegC, ±1K
- Cooling Performance: <15 min, 50–20 DegC, ±1K
- Capacity: 2 column slots
Customization/Options: N/A
Testing performed by our in-house service team:
The Vanquish Flex Quaternary UHPLC System passed all tests and was found to be fully functional:
Vanquish Quaternary Pump F:
- We performed the initialization test.
- We conducted the self-test.
- We verified the software communication test.
- We performed the gradient proportioning valve test.
- We completed the seal-washing pump test.
- We ran the pressure limiter test.
- We tested the flow rate accuracy.
- We ran a solvent delivery stability.
Vanquish Split Sampler FT:
- We conducted the initialization test.
- We checked the software communication.
- We tested the sample cooler set temperature accuracy.
- We performed the needle wash test.
- We carried out the reproducibility test.
Vanquish Column Compartment H:
- We conducted the initialization test.
- We verified the software communication.
- We conducted the heating and cooling test.
- We checked the leak sensor.
Vanquish Variable Wavelength Detector F:
- We performed the initialization test.
- We verified the software communication.
- We checked the leak sensor.
- We conducted test injections of the test solution and verified the peaks.
Vanquish Fluorescence Detector F:
- We performed the initialization test.
- We verified the software communication.
- We checked the leak sensor.
- We conducted test injections of the test solution and verified the peaks.
Instrument Overview:
- Vanquish Flex Quaternary UHPLC System with Variable Wavelength and Fluorescence Detectors, configured for high‑resolution liquid chromatography.
- Quaternary pump provides four‑solvent mixing with precise gradient formation, supporting complex separations and method flexibility.
- Integrated static mixer (350 µL) minimizes dispersion and improves gradient stability, delivering sharper peaks and better reproducibility.
- Split‑loop autosampler enables accurate, low‑carryover injections with high precision and supports small‑volume/vial sample handling.
- Thermostatted column compartment offers tight temperature control with enhanced stability, improving retention time consistency and resolution.
- Dual detection combines VWD for quantitative absorbance measurements and FLD for highly sensitive, selective fluorescence analysis.
Instrument Application:
- Pharmaceutical assay and impurity profiling
- Trace detection of fluorescent biomarkers
- Bioanalytical quantification of proteins and peptides
- Stability testing and degradation studies
- Multi‑component mixture separation and identification
The Key Features:
- Quaternary 4‑solvent gradient control
- Low‑dispersion static mixer (350 µL)
- High‑precision split‑loop autosampler
- Tight column temperature regulation
- Dual detection: VWD + fluorescence
- Modular, UHPLC‑ready platform
Additional technical info:
- Manual: Thermo Vanquish UHPLC Manual
- Manual: Vanquish Split Sampler FT Manual
- Manual: Vanquish Quaternary Pump F Manual
- Manual: Vanquish Column Compartment H Manual
- Manual: Vanquish Variable Wavelength Detector Manual
- Manual: Vanquish Fluorescence Detector Manual
Video Overview:
About us

How we pack

VIEW SOME OF THE CUSTOMERS WE HELPED HERE
Why do so many customers choose to order from us?

- We have experience servicing and repairing these instruments.
- This instrument goes through all the described service steps before shipping. see the questions section below
- We offer detailed photos and videos of the instruments you buy.
- We are an approved pre-owned equipment vendor to many large US, Canadian, and EU Universities.
- We are an approved pre-owned equipment vendor to many Fortune 500 US and International Biopharma companies.
- Technical sales consultation available
- Remote installation and instrument operation training may be available.
- On-site installation may be available in the Boston Area (New England area)
- US or International shipping is no problem (see the shipping tab on how we pack and feel at ease)

- Warranty
- An extended warranty may be available
- You get after-sales technical support
- Customer references are available
- The instrument will be fully functional!
- Smooth process from the initial quote to order fulfillment
This will ship via freight. Please contact us with your zip code to obtain a shipping quote.
COMMON QUESTIONS AND ANSWERS BELOW
What are the steps you take to verify, service, and confirm the functionality of the Vanquish Flex Quaternary UHPLC System?
We verify various instrument functions individually and together, performing necessary repairs or maintenance to bring the instrument to our quality standards.
- We completed system initialization successfully
- We verified software communication across modules
- We confirmed pump self-test passed
- We validated gradient proportioning valve operation
- We checked flow rate accuracy within limits
- We demonstrated solvent delivery stability
- We verified autosampler needle wash performance
- We confirmed injection reproducibility
- We validated column compartment temperature control
- We checked detector response and peak integrity
What supplies do I need?
You will need the consumables starting out: HPLC and UHPLC Related Products | Thermo Fisher Scientific - US
Solvent Filters & Bottles
Tubing & Fittings
Autosampler Vials & Caps
Columns
Needle Wash Solvents
Detector-Specific Supplies
Can I view the Vanquish Flex Quaternary UHPLC System in person at your facility or do a live Zoom demo before it is shipped to me?
We invite you to visit our facility for an on-site demo or feel free to request a virtual Zoom demo of the instrument you are interested in.
What about the warranty? Installation, training, maintenance?
Warranty Terms:
- The instrument comes fully warranted for both parts and labor.
- The customer should retain all packing materials during the warranty period.
What should I watch out for when buying a Vanquish Flex Quaternary UHPLC System used/pre-owned from another lab?
- Make sure the instrument is properly packed for shipping and will arrive safely. If the instrument is large, request to have it packed in a wooden crate.
- Confirm that there is no physical damage or any misaligned internal components.
- Ask what accessories are included.
- Ask how long the warranty is and what it covers.
Here is what our technical team tests so you can request something similar and ensure your instrument will be fully functional.
- We completed system initialization successfully
- We verified software communication across modules
- We confirmed pump self-test passed
- We validated gradient proportioning valve operation
- We checked flow rate accuracy within limits
- We demonstrated solvent delivery stability
- We verified autosampler needle wash performance
- We confirmed injection reproducibility
- We validated column compartment temperature control
- We checked detector response and peak integrity
We recommend inspecting the instrument in person or requesting a virtual demo; this will allow you to evaluate the condition and performance of the instrument you are considering purchasing.
Do you have a Vanquish Flex Quaternary UHPLC System on hand?
- This is a common model, and we generally stock multiple instruments, accessories, and many replacement parts to back up our warranty.
I found it elsewhere for less. What goes into your price?
We acknowledge that sometimes you can purchase this model instrument elsewhere, possibly for less.
Here are some of the reasons for our price.
- We may offer longer warranty terms.
- We cover shipping costs during the warranty period. (Customer is required to save packing materials for the duration).
- We have to have technical staff that can do the testing/repairs and after-sales support if there are any issues.
- We invest considerable time into the testing and service of each instrument we sell.
- We have to purchase various testing supplies (often expensive) to perform testing.
- We have to purchase any missing required accessories to make the instruments complete.
- We have to procure and stock service parts to support our warranty.
- We have extensive experience packing sensitive instruments. See the shipping section in the website menu for info on how not to pack.
- We guarantee that the instrument will be functional.
This procurement is for a University or College. Are purchase orders with NET terms accepted?
- If you are a US or Canadian customer, we are likely already a registered vendor in your University's vendor system. This would greatly expedite the process of PO approvals and get this instrument into your lab faster.
- POs are accepted from US and Canadian universities.
How fast will you ship?
- We can ship within a few days to two weeks. Shipping time depends on the current demand for our instruments. Members of our sales team will be able to offer current delivery estimates.
Will my instrument be insured during shipping?
- All instruments shipped within the USA and internationally are fully insured. This applies as long as we are the shipper and handle shipping arrangements.
- If the buyer handles shipping, then shipping insurance responsibility falls to the buyer; we highly advise that the buyer obtain shipping insurance from their carrier.
How do you pack? Have you packed and shipped Vanquish Flex Quaternary UHPLC System Instruments in the past? Do you ship Internationally?
Packing
- Most larger instruments ship in fully enclosed ISPM15-certified wooden crates with proper padding underneath, and the sides have moving components braced.
- Accessories are packed safely in boxes with padding and then safely packed inside the crate.
- We may not use a crate for local deliveries to save you money *if delivered by us.
- We often use “tilt’ & “shock” indicators on the crates to ensure the crate has not been excessively tilted and dropped where equipment may suffer damage.
- Photos are taken during the packing process to make sure nothing is missed.
USA/Canada Shipping
- Within the US and Canada, we will ship via selected freight carriers. We do not use low-price/high-damage carriers as we want the equipment to get safely to you.
International Shipping
- Internationally, we will only ship via Air Freight or Air Parcel (such as UPS or DHL), which provides reliability, no exposure to Ocean weather, and timely delivery.
We have extensive experience packing and shipping fragile instruments globally.
Our experience and process
- We have safely packed and shipped thousands of sensitive analytical instruments.
How much will I save buying it pre-owned, and is it worth it?
A lot…and it is undoubtedly worth it, and here is why. Feel free to ask for feedback from hundreds of customers who bought from us.
- You will pay less than half vs. buying a new instrument. Why not spend leftover funds on another instrument for your lab?
- You will get our standard warranty, plus, when available, an option to obtain an extended warranty agreement.
- Know that your instrument was tested and working the day it left our facility and is covered if there are faults.
- Get extra peace of mind by adding an extended warranty or service agreement when such an option is available.
Sustainability
- Well, this one is easy: buying a pre-owned instrument is great for the planet; you are reducing unnecessary waste, CO2 output, and water use that would be used during the manufacturing process.
I have more questions; I want to receive a formal quote.
Absolutely! Please give us a call (1-617-397-3486) or complete this form to get your questions answered or receive a formal Quote.
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)

