Particle Size Range: 0.2 um to 1600 um in diameter Volume: 0.004 um^3 to 2.14 x 10^9 um^3 Aperture Size: 10uM - 2,000 uM (Nominal diameter) Aperture Current Range: 30uA - 6000uA in 0.2uA steps Aperture Current Accuracy: +/-0.4% of setting
Particle Size Range: 0.2 um to 1600 um in diameter Volume: 0.004 um^3 to 2.14 x 10^9 um^3 Aperture Size: 10uM - 2,000 uM (Nominal diameter) Aperture Current Range: 30uA - 6000uA in 0.2uA steps Aperture Current Accuracy: +/-0.4% of setting
Particle Size Range: 1.3 to 150 um Flow Rate: 10 mL/min (up to 100 mL/min, determined by the sensor calibration flow rate) Temperature Range of Sample: 5 to 40 DegC Sensor concentration limits: 18,000 particles/mL Viscosity Limit: <50 cP
Particle Size Range: 1.3 to 150 um Flow Rate: 10 mL/min (up to 100 mL/min, determined by the sensor calibration flow rate) Temperature Range of Sample: 5 to 40 DegC Sensor concentration limits: 18,000 particles/mL Viscosity Limit: <50 cP
Count Particles: in the size range 50nm - 5um Objective: Olympus 10x/0.25 LMPlanFL N Measures each particle independently Will differentiate oil droplets, air bubbles and protein aggregates by density Power: 120V 50/60Hz
Particle Size Range: 2 um to 300 um Objectives: 4x, 10x, 20x Flow Cells:50 um FOV, 80 um FOV, 300 um FOV Pump Syringe Size: 5 mL, 1 mL, 0.5 mL Frame Rate: up to 100 frames per second
High Throughput Bot1 Autosampler Size Range: 1um to 70um Percent of Sample Analyzed: >85% - entire size range Depth of Field (DOF): 100um Analysis Rate: 150 uL/min
High Throughput Bot1 Autosampler Size Range: 1um to 70um Percent of Sample Analyzed: >85% - entire size range Depth of Field (DOF): 100um Analysis Rate: 150 uL/min
Available Tests: Particle Counting Particle size range: 1.3 to 150um Number of Channels: 1 Flow Rate: 10 to 100 ml/min; Actual flow rate for the system is determined by the syringe pump Temperature Range of Sample: 5 to 40C
Available Tests: Particle Counting Particle Size Range: 1.3 to 150um Number of Channels: 1 Flow Rate: 10 to 100 ml/min; Actual flow rate for the system is determined by the syringe pump Temperature Range of Sample: 5 to 40C
Available Tests: Particle Counting Particle Size Range: 2 to 400um Number of Channels: 1 Flow Rate: 10 to 100 ml/min; Actual flow rate for the system is determined by the syringe pump Temperature Range of Sample: 5 to 40C
Available Tests: Particle Counting Particle size range: 2 to 400um Number of Channels: 1 Flow Rate: 10 to 100 ml/min; Actual flow rate for the system is determined by the sensor’s flow rate Temperature Range of Sample: 5 to 40C
Available Tests: Particle Counting Particle Size Range: 2 to 400um Number of Channels: 1 Flow Rate: 10 to 100 ml/min; Actual flow rate for the system is determined by the sensor’s flow rate Temperature Range of Sample: 5 to 40C
Available Tests: Particle Counting Particle Size Range: 1.3 to 150um Number of Channels: 1 Flow Rate: 10 to 100 ml/min; Actual flow rate for the system is determined by the syringe pump Temperature Range of Sample: 5 to 40C
Particle Size Range: 0.2 um to 1600 um in diameter Volume: 0.004 um^3 to 2.14 x 10^9 um^3 Aperture Size: 10uM - 2,000 uM (Nominal diameter) Aperture Current Range: 30uA - 6000uA in 0.2uA steps Aperture Current Accuracy: +/-0.4% of setting
Particle Size Range: 0.2 um to 1600 um in diameter Volume: 0.004 um^3 to 2.14 x 10^9 um^3 Aperture Size: 10uM - 2,000 uM (Nominal diameter) Aperture Current Range: 30uA - 6000uA in 0.2uA steps Aperture Current Accuracy: +/-0.4% of setting
Aperture Size: 10uM - 2,000 uM (Nominal diameter) Number of Channels: Pulse data is digitized and can be processed to achieve up to 400 size channels for a selected pulse range. Number of channels and range can be reprocessed as necessary Electrolyte Solutions: All aqueous and non-aqueous electrolyte solutions recommended for use with aperture technology will be suitable for use. Aperture Current Range: 30uA - 6000uA in 0.2uA steps Aperture Current Accuracy: +/-0.4% of setting