-800x600w.jpg)
-800x600w.jpg)
-800x600w.jpg)
-800x600h.png)
-800x600h.png)
-80x80w.jpg)
-80x80w.jpg)
-80x80w.jpg)
-80x80h.png)
-80x80h.png)
![]() | Approved Vendor to many US, Canada, and EU Universities |
![]() | International Shipping |
![]() | Customer References Available |
![]() | Training and Installation Options Available |
- Stock: In Stock
- Brand: Thermo Scientific
- Product ID: 69299
- Condition: Pre-Owned
For Sale Thermo Scientific Vanquish Flex Duo UHPLC System w/ Dual Variable Wavelength Detectors
- Fully Functional
- Serviced & in Stock
- Current Model
- Made in 2024
- Good cosmetic condition
- Technical sales consultation available
- WARRANTY
Here is what you will receive:
Vanquish Dual Pump F p/n VF-P32-A-01 w/ Static Mixers, volume: 350 uL
Vanquish Dual Split Sampler FT p/n VF-A40-A-02 with 2x 100uL loop
Vanquish Column Compartment H p/n: VH-C10-A
Active pre-heater, 0.1 x 610 mm, MP35N p/n 6732.0150 - Qty 2
Post-column cooler, 1uL, 0.1 x 590 mm p/n 6732.0520 - Qty 2
Column-ID Tag p/n 6732.0610 - Qty 1
Vanquish Integral Fraction collector FT p/n VF-F20-A-01
Delay capillary <0.5 ml/min p/n 6706.1100
Delay capillary 0.5-1ml/min p/n 6706.1110
Vanquish Variable Wavelength Detector F p/n: VF-D40-A with semi-micro Bio flow cell, Bio (2.5uL,7mm,50bar) p/n 6077.0300
Vanquish Variable Wavelength Detector F p/n: VF-D40-A with semi-micro Bio flow cell, Bio (2.5uL,7mm,50bar) p/n 6077.0300
Solvent rack Qty 2
System base Qty 2
PC loaded with Chromeleon v.7.3.2
Inter-communication cables
Standard power cords
New Thermo Scientific™ SureSTART™ 2ml vial set - Qty 2
Vanquish Flex Duo HPLC System Configuration:
Vanquish Dual Split Sampler FT:
Injection units: 2
Operating principle: split loop injection
Pressure range: 2–103 MPa
Injection volume range: 0.01–100 uL, min. Step = 0.01 uL
Injection volume accuracy: typically ±0.5% for 10 uL water
Injection volume precision: <0.25% area RSD for 1 uL (caffeine in water); typically <0.5% area RSD for 0.5 uL (caffeine in water)
Injection linearity: r > 0.99999 (caffeine in water)
Injection cycle time: down to 8s depending on separation conditions
Minimum sample required: 2 uL at 1 uL injection volume
Carryover (UV): <0.002% with caffeine (typically: <0.0004%)
Needle wash (external): 1 solvent per injection unit, dip rinse and continuous rinse
Sample compartment temperature range: 4-40 DegC (≥23 K below ambient at <80% RH)
Sample temperature accuracy: -2 DegC/+4 DegC
Sample temperature stability: ±1 DegC
Sample capacity: 4 segments usable for sample racks or well plates with SBS footprint format; plus a capacity of 12 x 22.5 mm O.D. vials in the carousel
Barcode reading: empty segment detection, rack/well plate verification, inventory management
(2) x Vanquish Variable Wavelength Detector F:
Optical design: UV/VIS/NIR photometer (tunable Czerny-Turner monochromator) with additional internal reference beam
Light source: Deuterium lamp for UV and VIS; Tungsten lamp for VIS and NIR
Wavelength range: 190–900 nm (with deuterium and tungsten lamp)
Spectral bandwidth: typ. 6 nm at 254 nm
Wavelength Accuracy: ± 1 nm
Wavelength Repeatability: ± 0.1 nm
Wavelength Calibration: Internal calibration with zero order of monochromator spectrum
Wavelength Validation: Internal validation with holmium-oxide filter
Signal channel: Up to 4 signal channels
Data collection rate (single-channel): up to 250 Hz; (multi-channel) up to 5 Hz
Noise (single-channel): <±2.5 uAU at 254 nm
Noise (multi-channel): <±10 uAU (typical <±7 uAU) at 254 nm and 280 nm
Drift: <0.1 mAU/h at 254 nm
Linearity: <5% at 2.5 AU (typical <3% at 2.5 AU
Flow Cell: Semi-micro flow cell, biocompatible (2.5 uL, 7 mm, 5 MPa)
Vanquish Column Compartment H:
Operating Principle Column Chamber: still air and forced air
Temperature Range: 5-120 DegC in 0.1 DegC increments (18K below ambient)
Temperature Stability: ±0.05K
Temperature Accuracy: ±0.5K (up to 80 DegC)
Heating Performance: <15 min, 20–50 DegC, ±1K Typical: 5 min, 25–40 DegC, ±1K
Cooling Performance: <15 min, 50–20 DegC, ±1K
Capacity: 2 column slots
Temperature Zones: 1 per device (up to 3 zones in stacked configuration)
Column ID: 4 column ID tags
Pre-heater:
Operating Principle: active
Temperature Range: 40–120 DegC (5K above ambient)
Temperature Stability: ±0.5K
Temperature Accuracy: ±2K
Heating Performance: 80 DegC at 2.5 mL/min, 120 DegC at 1 mL/min (water/acetonitrile (50/50, v/v))
Capacity: 2 column slots
Post-column Cooler:
Operating Principle: passive
Temperature Range: 40-80 DegC
Temperature Stability: ±0.05K
Temperature Accuracy: ±2K (up to 80 DegC)
Cooling Performance: Down to 50 DegC at 2 mL/min and 120 DegC column temperature
Vanquish Dual Pump F: 2-Pump-Unit
Operating Principle: serial dual-piston pump
Flow Range: 0.001–8 mL/min, in 1 uL/min increments
Pressure Range: 2–103 MPa; at flow rates>5 mL/min, the pressure range decreases to 80 MPa
Compressibility Compensation: fully automated, independent of the composition of the mobile phase
Flow Accuracy: ±0.1%
Flow Precision: <0.05% RSD or <0.01 min SD, whichever is greater
Pulsation typically: <1.0% or <0.2 MPa, whichever is greater
Gradient Formation: dual low-pressure gradient proportioning
Proportioning Accuracy: ±0.5% of full-scale
Proportioning Precision: <0.15% SD
Number of Solvent Lines: 2x3
Mixer Volume: 350 uL static mixer (for total volume of mixing system 400 uL)
Dwell Volume: 679 uL
Solvent Degassing: built-in, 6 Channels
Vanquish Fraction collector FT:
Sample Capacity: up to 4 SBS-format racks or well plates
Collection Formats: vials and 96/384-well plates
Flow Range: 0.05 to 10 mL/min
Temperature Control: 4 °C to 40 °C cooled compartment
Collection Modes: peak- or time-based fractionation
Barcode Support: rack verification and inventory tracking
Customization/Options: (Please inquire to check availability of stock for any options)
Different flow cells for detectors.
Other add-on components such as ELSD, mass spectrometers, etc.
Sample racks
Testing performed by our in-house service team:
The Vanquish Flex Duo HPLC System passed all tests and was found to be fully functional:
Vanquish Dual Pump F
We performed the initialization test.
We completed the system self-test.
We verified the gradient proportioning valve operation.
We completed the seal wash pump functionality test.
We performed the pressure limiter test.
We verified the flow rate accuracy.
We evaluated the solvent delivery stability.
Vanquish Column Compartment H
We performed the initialization test.
We verified communication with the control software.
We completed the heating and cooling performance test.
We verified the operation of the active column preheater.
We tested the leak sensor functionality.
Vanquish Variable Wavelength Detector F
We performed the initialization test.
We tested the leak sensor functionality.
We conducted test injections and verified the resulting chromatographic peaks.
Vanquish Split Sampler FT
We performed the initialization test.
We verified the sample cooler temperature accuracy.
We completed the needle wash functionality test.
We performed the injection reproducibility test.
Fraction Collector FT
We performed the initialization test.
We verified communication with the control software.
We tested the leak sensor functionality.
We verified the fraction collection accuracy.
We evaluated the tray movement functionality.
Instrument Application:
Pharmaceutical compound analysis
Method development and optimization
Impurity and degradation studies
Biomolecule and protein separations
Fraction collection and purification workflows
Quality control and research laboratories
The Key Features:
Dual-pump low-pressure gradient design
Dual UV/VIS wavelength detectors
103 MPa UHPLC pressure capability
Dual split-loop injection system
Integrated fraction collection module
Heated column compartment system
Additional technical info:
Manual: Thermo Vanquish UHPLC Manual
Manual: Vanquish Split Sampler FT Manual
Manual: Vanquish Dual Pump F Manual
Manual: Fraction Collector FT Manual
Video Overview:
About us

How we pack

VIEW SOME OF THE CUSTOMERS WE HELPED HERE
Why do so many customers choose to order from us?

- We have experience servicing and repairing these instruments.
- This instrument goes through all the described service steps before shipping. see the questions section below
- We offer detailed photos and videos of the instruments you buy.
- We are an approved pre-owned equipment vendor to many large US, Canadian, and EU Universities.
- We are an approved pre-owned equipment vendor to many Fortune 500 US and International Biopharma companies.
- Technical sales consultation available
- Remote installation and instrument operation training may be available.
- On-site installation may be available in the Boston Area (New England area)
- US or International shipping is no problem (see the shipping tab on how we pack and feel at ease)

- Warranty
- You get after-sales technical support
- Customer references are available
- The instrument will be fully functional!
- Smooth process from the initial quote to order fulfillment
This will ship via freight. Please contact us with your zip code to obtain a shipping quote.
COMMON QUESTIONS AND ANSWERS BELOW
What are the steps you take to verify, service, and confirm the functionality of the Vanquish Flex Duo HPLC System?
We verify various instrument functions individually and together, performing necessary repairs or maintenance to bring the instrument to our quality standards.
- We perform system initialization and complete all module self-tests.
- We verify communication between all modules and the control software.
- We confirm accurate solvent delivery, gradient formation, and flow rate performance.
- We test autosampler injection accuracy, reproducibility, and needle wash operation.
- We verify sample compartment temperature control and cooling performance.
- We test column compartment heating, cooling, and active preheater functionality.
- We conduct detector performance checks and verify chromatographic peak response.
- We test fraction collection accuracy and tray movement functionality.
- We verify the operation of all installed leak sensors.
- We confirm stable system operation and successful completion of functional testing.
What supplies do I need?
You will need the consumables starting out: HPLC and UHPLC Related Products | Thermo Fisher Scientific - US
Solvent Filters & Bottles
Tubing & Fittings
Autosampler Vials & Caps
Columns
Needle Wash Solvents
Detector-Specific Supplies
Can I view the Vanquish Flex Duo HPLC System in person at your facility or do a live Zoom demo before it is shipped to me?
We invite you to visit our facility for an on-site demo or feel free to request a virtual Zoom demo of the instrument you are interested in.
What about the warranty? Installation, training, maintenance?
Warranty Terms:
- The instrument comes fully warranted for both parts and labor.
- The customer should retain all packing materials during the warranty period.
What should I watch out for when buying a Vanquish Flex Duo HPLC System used/pre-owned from another lab?
- Make sure the instrument is properly packed for shipping and will arrive safely. If the instrument is large, request to have it packed in a wooden crate.
- Confirm that there is no physical damage or any misaligned internal components.
- Ask what accessories are included.
- Ask how long the warranty is and what it covers.
Here is what our technical team tests so you can request something similar and ensure your instrument will be fully functional.
- We perform system initialization and complete all module self-tests.
- We verify communication between all modules and the control software.
- We confirm accurate solvent delivery, gradient formation, and flow rate performance.
- We test autosampler injection accuracy, reproducibility, and needle wash operation.
- We verify sample compartment temperature control and cooling performance.
- We test column compartment heating, cooling, and active preheater functionality.
- We conduct detector performance checks and verify chromatographic peak response.
- We test fraction collection accuracy and tray movement functionality.
- We verify the operation of all installed leak sensors.
- We confirm stable system operation and successful completion of functional testing.
We recommend inspecting the instrument in person or requesting a virtual demo; this will allow you to evaluate the condition and performance of the instrument you are considering purchasing.
Do you have a Vanquish Flex Duo HPLC System on hand?
- This is a common model, and we generally stock multiple instruments, accessories, and many replacement parts to back up our warranty.
I found it elsewhere for less. What goes into your price?
We acknowledge that sometimes you can purchase this model instrument elsewhere, possibly for less.
Here are some of the reasons for our price.
- We may offer longer warranty terms.
- We cover shipping costs during the warranty period. (Customer is required to save packing materials for the duration).
- We have to have technical staff that can do the testing/repairs and after-sales support if there are any issues.
- We invest considerable time into the testing and service of each instrument we sell.
- We have to purchase various testing supplies (often expensive) to perform testing.
- We have to purchase any missing required accessories to make the instruments complete.
- We have to procure and stock service parts to support our warranty.
- We have extensive experience packing sensitive instruments. See the shipping section in the website menu for info on how not to pack.
- We guarantee that the instrument will be functional.
This procurement is for a University or College. Are purchase orders with NET terms accepted?
- If you are a US or Canadian customer, we are likely already a registered vendor in your University's vendor system. This would greatly expedite the process of PO approvals and get this instrument into your lab faster.
- POs are accepted from US and Canadian universities.
How fast will you ship?
- We can ship within a few days to two weeks. Shipping time depends on the current demand for our instruments. Members of our sales team will be able to offer current delivery estimates.
Will my instrument be insured during shipping?
- All instruments shipped within the USA and internationally are fully insured. This applies as long as we are the shipper and handle shipping arrangements.
- If the buyer handles shipping, then shipping insurance responsibility falls to the buyer; we highly advise that the buyer obtain shipping insurance from their carrier.
How do you pack? Have you packed and shipped Vanquish Flex Duo HPLC System Instruments in the past? Do you ship Internationally?
Packing
- Most larger instruments ship in fully enclosed ISPM15-certified wooden crates with proper padding underneath, and the sides have moving components braced.
- Accessories are packed safely in boxes with padding and then safely packed inside the crate.
- We may not use a crate for local deliveries to save you money *if delivered by us.
- We often use “tilt’ & “shock” indicators on the crates to ensure the crate has not been excessively tilted and dropped where equipment may suffer damage.
- Photos are taken during the packing process to make sure nothing is missed.
USA/Canada Shipping
- Within the US and Canada, we will ship via selected freight carriers. We do not use low-price/high-damage carriers as we want the equipment to get safely to you.
International Shipping
- Internationally, we will only ship via Air Freight or Air Parcel (such as UPS or DHL), which provides reliability, no exposure to Ocean weather, and timely delivery.
We have extensive experience packing and shipping fragile instruments globally.
Our experience and process
- We have safely packed and shipped thousands of sensitive analytical instruments.
How much will I save buying it pre-owned, and is it worth it?
A lot…and it is undoubtedly worth it, and here is why. Feel free to ask for feedback from hundreds of customers who bought from us.
- You will pay less than half vs. buying a new instrument. Why not spend leftover funds on another instrument for your lab?
- You will get our standard warranty, plus, when available, an option to obtain an extended warranty agreement.
- Know that your instrument was tested and working the day it left our facility and is covered if there are faults.
- Get extra peace of mind by adding an extended warranty or service agreement when such an option is available.
Sustainability
- Well, this one is easy: buying a pre-owned instrument is great for the planet; you are reducing unnecessary waste, CO2 output, and water use that would be used during the manufacturing process.
I have more questions; I want to receive a formal quote.
Absolutely! Please give us a call (1-617-397-3486) or complete this form to get your questions answered or receive a formal Quote.
.jpg)
.jpg)
.jpg)
.png)
.png)

