Application: for dry, fine-grained and also cohesive powders (powders, suspensions, emulsions, sprays and aerosols) Particle Detection Range: integrates up to 5 optical modules for a range 0.1um - 875um Sample amount per analysis < 1 g to 1,000 g 3R 633nM 5mW laser Equipped Options: VIBRI/L, RODOS
Reagents: disposable single cartridge Cell Counts: > 1,250 isolated cells per chip Multiplex: up to 36 analytes per isolated single cell Hands-On Time:< 3 min per sample On-Board Incubator: Temperature: 37 ± 2DegC; CO2 concentration: 5 ± 1%
Dispense volume: 35 nl, 50 nl, or 100 nl per nanowell Dispenser nozzle bore size: 125 um Fuses Dispenser; 4 Ah, 250 V Dimensions: 42.5 x 23 x 23 in (108 x 58 x 58 cm) Weight: 200 lbs
Test Positions: 7 (6 test samples and 1 placebo) Water Bath Capacity: 8L 22.6mm Tablet Cells Temperature Range: +5C to 45C C 615 collector capable of 7 collections at a time
4D-Nucleofector System for transfection of cells with DNA, RNA, or other molecules 4D-Nucleofector LV Unit for large-scale transfection of up to 1x10^9 cells Transfections per minute: (LV Nucleocuvette Cartridges): 2-3 mL The Core Unit can be used to operate X, Y, LV and 96-well Units Established Protocols - benefit from 700+ optimized cell types
12L airlock with a 60 second cycle time and sliding interior door Incubation Range: 5C above ambient up to a maximum working temperature of 45C Regulator Outlet Range: 4-6 bar (60-90 psi) Flow Rate: 150L per minute (Dynamic) Input Voltage: 230V 50Hz Single Phase 115V 60Hz Single Phase
3 dispensing channels Program line length and volume Programmable X, Y and Z axes Independent volume control for each channel Quantitative, simultaneous dispensing; Dot and Line dispensing
Heat Source: Platinum Filament with Safe Heat Mode Tip Size Range 0.06 um - 3 um Taper Length Range 3 mm - 15 mm Number of Programs: 100 Program Spots Program Lines: 4 and Line Repeat Mode
Sotax CE 7 Smart Dissolution tester with Sotax CP7 pump and Sotax C 615 fraction collector (7) flow cell capacity for (6) test samples and (1) placebo Capable of testing 5 different cell types for tablets (12mm and 24mm), implants, granulates and powders, suppositories and gel caps LCD screen with keypad interface Temperature range for dissolution system: room temperature +5C to 45C +/-0.2C
Detection Technology: Bio-Layer Interferometry (BLI) Biosensor Type: disposable, single-use fiber optic biosensors with optional reuse by regeneration and/or re-racking Throughput: up to 8 assays in parallel; up to 96 assays per 96-well plate Baseline Noise: =< 3.5 pm (RMS) Quantitation Range for hIgG: 0.5 ug/mL to 2000 ug/mL at 400 rpm, 0.05 ug/mL to 100 ug/mL at 1000 rpm
LV Unit: for Large-Scale Transfection Closed System - sterile Nucleofection of up to 109 cells Established Protocols - benefit from 700+ optimized cell types Simple Handling - minimal training needs
X Unit: Supporting Nucleofection of various cell numbers in different formats (16-well Nucleocuvette Strips or 100 uL Nucleocuvette Vessels) LV Unit: Large-scale transfection of up to 1x109 cells Transfections per minute: X Unit (16-well Nucleocuvette Strips): 16-32 reactions; X Unit (100 uL Nucleocuvette Vessels): 20-26 reactions; LV Unit (LV Nucleocuvette Cartridges): 2-3 mL Dimensions: (WxHxD): 24.5 x 14.7 x 28 cm / 9.7 x 5.8 x 11.0in; Weight: 4.4 kg (9.7 lb) Power: 100 - 240 VAC