Multi-channel brightfield and fluorescence imaging cytometer (4) fluorescent channels (Blue, Green, Red and Far-Red) allow multiplexed assays Label-free live cell assays Compatible with 96-, 384- and 1536- well plates High-Speed Imaging: Less than 2 min for 384-well plate
Imaging method: visible light trans-illumination, high resolution 16-bit greyscale CCD line imager Imaging resolution: user selectable between 300 - 2,400 ppi Depth of field: up to 5mm effective, above well base Sample loading method: removable loading tray Plasticware supported: multi-well plates 6, 12, 24, 48 and 96-well plates with/without lids
Imaging method: visible light trans-illumination, high resolution 16-bit greyscale CCD line imager Imaging resolution: user selectable between 300 - 2,400 ppi Depth of field: up to 5mm effective, above well base Sample loading method: removable loading tray, latching into a software-controlled motorized drawer Plasticware supported: multi-well plates (6, 12, 24, 48 and 96-well plates with/without lids; 35, 50/60 and 100mm Petri dishes with/without lids; selected T25 flasks
Imaging method: visible light trans-illumination, high resolution 16-bit greyscale CCD line imager Imaging resolution: user selectable between 300 - 2,400 ppi Depth of field: up to 5mm effective, above well base Sample loading method: removable loading tray, latching into a software-controlled motorized drawer Plasticware supported: multi-well plates (6, 12, 24, 48 and 96-well plates with/without lids; 35, 50/60 and 100mm Petri dishes with/without lids; selected T25 flasks
Multi-channel brightfield and fluorescence imaging cytometer (3) fluorescent channels (Blue, Green, & Red) allow multiplexed assays Label-free live cell assays Compatible with 96-, 384- and 1536- well plates High-Speed Imaging: Less than 2 min for 384-well plate
Multi-channel brightfield and fluorescence imaging cytometer (4) fluorescent channels (Blue, Green, Red and Far-Red) allow multiplexed assays Label-free live cell assays Compatible with 96-, 384- and 1536- well plates High-Speed Imaging: Less than 2 min for 384-well plate
Cell Density Range: 5x10^4 to 1x10^7 cells/mL Cell Viability Method: 2-70 um Counting Accuracy: +/- 10% Effective Resolution: 1 um per pixel Minimum Sample Volume: 500 uL
Cell Density Range: 5x10^4 to 1x10^7 cells/mL Cell Viability Method: 2-70 um Counting Accuracy: +/- 10% Effective Resolution: 1 um per pixel Minimum Sample Volume: 500 uL
Cell density range: 5x10^4 to 1.5x10^7 cells/mL Cell Viability Method: Trypan blue dye exclusion method Counting Accuracy: +/- 10% Effective Resolution: 0.5 um per pixel Minimum sample volume: 200 uL in normal Mode, 170 uL in fast Mode
Cell density range: 5x10^4 to 1.5x10^7 cells/mL Cell Viability Method: Trypan blue dye exclusion method Counting Accuracy: +/- 10% Effective Resolution: 0.5 um per pixel Minimum sample volume: 200 uL in normal Mode, 170 uL in fast Mode
Enzymatic and fluorescent analysis <3 minutes for an enzymatic EliSpot plate, ≈10 minutes for a 2-color FluoroSpot plate Digital Firewire Camera, 2 megapixel, color, optimized for fluorescence imaging LED ring illumination, XBO light source, 3&1 filter wheel (2) narrow-band hard coated fluorescent filters (FITC and Cy3) on board