Menu
Your Cart

Agilent 1260 Infinity II LC System with InfinityLab LC MSD/XT G6135B Mass Selective Detector

Agilent 1260 Infinity II LC System with InfinityLab LC MSD/XT G6135B Mass Selective Detector
Agilent 1260 Infinity II LC System with InfinityLab LC MSD/XT G6135B Mass Selective Detector
Approved Vendor to many US, Canada, and EU Universities
International Shipping
Customer References Available 
Training and Installation Options Available

 

  • Stock: In Stock
  • Brand: Agilent
  • Product Code: 53137
  • Condition: Pre-Owned
$27,995.00
CLICKABLE TABS BELOW

For Sale Agilent 1260 Infinity II LC System with InfinityLab LC MSD/XT G6135B Mass Selective Detector

 

Please note that the system will require Agilent Service; please see the notes below.

It is priced accordingly. 

 

LC MSD/XT G6135B by itself is sold new by Agilent for around $140,000.00

 


 

Here is what you will receive:

  • Agilent 1260 Infinity II Fluorescence Detector (FLD) p/n: G7121A  w/ standard flow cell 8ul, 20bar
  • Agilent 1260 Infinity II Multicolumn Thermostat p/n: G7116A
  • Agilent 1260 Infinity II Vialsampler p/n: G7129C
  • Agilent 1260 Infinity II Quaternary Pump p/n: G7111B
  • Agilent InfinityLab LC XT Mass Selective Detector (MSD) p/n: G6135B
  • Electrospray Ionization (ESI) Source p/n: G1948B
  • Solvent bottle tray
  • Agilent MS40+ Rotary Vane Pump p/n: G6301-80040
  • Power and communication cables

 

LC MSD/XT G6135B by itself sold new by Agilent for around $140,000.00

 

Please Note: The computer and/or OpenLab CD software and proper licenses for final configuration should be purchased separately from Agilent. They are not included. 

 

Agilent 1260 Infinity ll LC System Configuration:

Fluorescence Detector (FLD) G7121A:

  • Detection type: one signal wavelength (excitation and emission)
  • Single wavelength operation RAMAN (H2O): > 500 (noise reference measured at signal)/ > 3000 (noise reference measured at dark value): Ex=350 nm, Em=397 nm, dark value 450 nm, standard flow cell
  • Light source: xenon flash lamp
  • Pulse frequency: 296Hz for single signal mode, 74Hz for economy mode
  • Maximum data rate: 74Hz
  • Excitation/Emission monochromator range: settable 200nm - 1200nm and zero-order; bandwidth: 20 nm (fixed)
  • Reference system: in-line excitation measurement
  • Timetable programming: single signal wavelength, response time, PMT Gain, baseline behavior (append, free, zero)
  • Wavelength repeatability: +/-0.2nm
  • Wavelength Accuracy +/-3nm

 

Multicolumn Thermostat G7116A:

  • Temperature range: 10 DegC below ambient (minimum 4 DegC) to 85 DegC
  • Temperature range increment: settable in steps of 0.1 DegC
  • Temperature stability ±0.1 DegC
  • Temperature accuracy ±0.5 DegC (with calibration at 40 DegC)
  • Temperature precision 0.05 DegC
  • Independent temperature zones: 2 in single device
  • Column capacity: 4 columns of up to 300 mm length plus InfinityLab Quick Connect fittings or pre-column.
  • Heat-up/cool-down time: 5 min from ambient to 40 DegC; 10 min from 40 DegC to 20 DegC; 25 min from 25 DegC to 85 DegC

 

Vialsampler G7129C:

  • Injection range: 0.1 – 100 ul in 0.1 ul increments with 100 ul up to 80 MPa
  • Injection precision: <0.25% RSD of peak areas from 5 uL to 100 uL
  • Pressure range: 0-80 MPa
  • Sample viscosity range: 0.2 - 5.0 cP
  • Sample capacity: 100 x 2mL vial
  • Carryover: <0.004 % (40 ppm) with needle wash
  • Injection cycle time: 18s. for draw speed 200 uL/min (ejection speed: 200 uL/min, injection volume: 1 uL)
  • Minimum sample volume: 1 uL from 5 uL sample in 100 uL microvial, or 1 uL from 10 uL sample in 300 uL microvial

 

Quaternary Pump G7111B:

  • Hydraulic system: dual piston in series pump with servo-controlled variable stroke drive floating pistons
  • Flow range: 0.001 – 10 mL/min in 0.001 mL/min increments
  • Flow precision: ≤0.07% RSD, or ≤0.02 min SD, whichever is greater
  • Flow accuracy: ±1% or 10 ul/min, whichever is greater
  • Pressure operating range: up to 60 MPa at 5 mL/min; up to 20 MPa at 10 mL/min
  • Pressure pulsation: <2% amplitude (typically <1.3%), or <0.3 MPa, whichever is greater
  • Compressibility compensation: user-selectable, based on mobile phase compressibility
  • Delay volume: 600-900 ul, dependent on back pressure
  • Composition range: 0-100% in 0.1 % increments
  • Composition precision: <0.2% RSD or <0.04 min SD, whichever is greater
  • Integrated degassing unit number of channels: 4
  • Internal volume per channel: 1.5 mL

 

Mass Selective Detector LC/MSD XT 6135 / G6135B:

  • Mass range: 2-3000 m/z
  • SIM sensitivity: signal-to-noise ratio, RMS >300:1
  • Maximum scan speed: 10400 u/sec
  • Polarity switching: 30 msec
  • Mass resolution: unit resolution (≤0.7 u (Da)
  • Mass stability: ~0.1u (Da) or 100 ppm, whichever is larger
  • Mass accuracy: ±0.005u (Da)
  • Spectral accuracy: 99.0%
  • Minimum SIM dwell time: 5 msec
  • Maximum SIM transitions: 100 SIM ions per time segment
  • Dynamic range: >6×106 (electronic)

 

Customization/Options:

  • Other detectors might be available. Please inquire with our sales team.

 

Testing performed by our in-house service team:

The Agilent 1260 Infinity ll LC System passed the following tests and was found to be functional:

 

Quaternary Pump G7111B:

  • We performed the initialization test.
  • We completed the software communication test.
  • We tested the solvent selection valve.
  • We conducted the system leak test.
  • We checked the degasser.
  • We tested the pressure limiter.
  • We verified the flow rate accuracy.
  • We assessed the solvent delivery stability.
  • We conducted the leak sensor test.

 

Vialsampler G7129C:

  • We performed the initialization test.
  • We completed the software communication test.
  • We verified the sample cooler set temperature accuracy.
  • We conducted the sampler leak test.
  • We tested the reproducibility.
  • We conducted the leak sensor test.

 

Multicolumn Thermostat G7116A:

  • We performed the initialization test.
  • We completed the software communication test.
  • We assessed the cooling and heating performance.
  • We verified the column oven temperature accuracy.
  • We conducted the leak sensor test.

 

Fluorescence Detector (FLD) G7121A:

  • We performed the initialization test.
  • We completed the software communication test.
  • We conducted the Raman signal/noise test.
  • We verified the wavelength accuracy: FAILED (Upon inspection, we found the cause to be due to UV-damaged mirrors)
  • We conducted the leak sensor test.

 

Mass Selective Detector LC/MSD XT 6135 / G6135B:

  • We performed the initialization test.
  • We completed the software communication test.
  • We conducted the tune procedure: FAIL (fragmentor fault error will need service to fix).

 

 

Please note that the system has faults as described above and is being sold AS IS/No Warranty/Returns. It will require Agilent Service.

The system is priced accordingly

 

Instrument Overview:

  • The Agilent 1260 Infinity II LC System offers high-performance liquid chromatography with enhanced ease of use and flexibility.
  • It includes the InfinityLab LC XT Mass Selective Detector, providing sensitive and reliable mass detection.
  • This system delivers excellent resolution and precision, making it suitable for a wide range of analytical needs.
  • Features robust construction and intuitive operation for efficient workflows and consistent results.
  • The Agilent 1260 Infinity II ensures accurate and reproducible data with its advanced detection capabilities.
  • Designed for enhanced productivity, it supports various detection methods for comprehensive analysis.

 

Instrument Application:

  • Pharmaceutical compound analysis
  • Environmental contaminant detection
  • Food and beverage quality control
  • Clinical research and diagnostics
  • Biochemical and protein studies

 

The Key Features:

  • High-resolution LC system
  • InfinityLab LC XT detector
  • Enhanced sensitivity
  • Fast and efficient analysis
  • Robust and reliable performance

 

Additional technical info:

 

Video Overview:

 

 

About us

 

How we pack

 


Why do so many customers choose to order from us?

 

  • We offer detailed photos and videos of the instruments you buy.
  • We are an approved pre-owned equipment vendor to many large US, Canadian, and EU Universities.
  • We are an approved pre-owned equipment vendor to many Fortune 500 US and International Biopharma companies.
  • Technical sales consultation available
  • US or International shipping is no problem (see the shipping tab on how we pack and feel at ease)

 


This will ship via freight. Please contact us with your zip code to obtain a shipping quote.

 

 

COMMON QUESTIONS AND ANSWERS BELOW

 

What are the steps you take to verify, service, and confirm the functionality of the Agilent 1260 Infinity ll LC System?

We verify various instrument functions individually and together, performing necessary repairs or maintenance to bring the instrument to our quality standards..

Quaternary Pump:

  • We performed the initialization test.
  • We completed the software communication test.
  • We tested the solvent selection valve.
  • We conducted the system leak test.
  • We checked the degasser.
  • We tested the pressure limiter.
  • We verified the flow rate accuracy.
  • We assessed the solvent delivery stability.
  • We conducted the leak sensor test.

Vialsampler:

  • We performed the initialization test.
  • We completed the software communication test.
  • We verified the sample cooler set temperature accuracy.
  • We conducted the sampler leak test.
  • We tested the reproducibility.
  • We conducted the leak sensor test.

Multicolumn Thermostat:

  • We performed the initialization test.
  • We completed the software communication test.
  • We assessed the cooling and heating performance.
  • We verified the column oven temperature accuracy.
  • We conducted the leak sensor test.

Fluorescence Detector:

  • We performed the initialization test.
  • We completed the software communication test.
  • We conducted the Raman signal/noise test.
  • We conducted the leak sensor test.

Mass Selective Detector XT:

  • We performed the initialization test.
  • We completed the software communication test.

 

What supplies do I need?

You will need the consumables starting out:

 

Can I view the Agilent 1260 Infinity ll LC System in person at your facility or do a live Zoom demo before it is shipped to me?

We invite you to visit our facility for an on-site demo, or feel free to request a virtual Zoom demo of the instrument you are interested in.

 

What about the warranty? Installation, training, maintenance?

Warranty Terms:

  • The instrument comes fuly warrantied for both parts and labor.
  • The customer should retain all packing materials during the warranty period.

 

What should I watch out for when buying a Agilent 1260 Infinity ll LC System used/pre-owned from another lab?
  • Make sure the instrument is properly packed for shipping and will arrive safely. If the instrument is large, request to have it packed in a wooden crate.
  • Confirm that there is no physical damage or any misaligned internal components.
  • Ask what accessories are included.
  • Ask how long the warranty is and what it covers.

 

We recommend inspecting the instrument in person or requesting a virtual demo; this will allow you to evaluate the condition and performance of the instrument you are considering purchasing.

 

Do you have a Agilent 1260 Infinity ll LC System on hand?
  • This is a common model, and we generally stock multiple instruments, accessories, and many replacement parts to back up our warranty.

 

I found it elsewhere for less. What goes into your price?

We acknowledge that sometimes you can purchase this model instrument elsewhere, possibly for less.

 

Here are some of the reasons for our price.

  • We may offer longer warranty terms.
  • We cover shipping costs during the warranty period. (Customer is required to save packing materials for the duration).
  • We have to have technical staff that can do the testing/repairs and after-sales support if there are any issues.
  • We invest considerable time into the testing and service of each instrument we sell.
  • We have to purchase various testing supplies (often expensive) to perform testing.
  • We have to purchase any missing required accessories to make the instruments complete.
  • We have to procure and stock service parts to support our warranty.
  • We have extensive experience packing sensitive instruments. See the shipping section in the website menu for info on how not to pack.
  • We guarantee that the instrument will be functional.

 

This procurement is for a University or College. Are purchase orders with NET terms accepted?
  • If you are a US or Canadian customer, we are likely already a registered vendor in your University's vendor system. This would greatly expedite the process of PO approvals and get this instrument into your lab faster.
  • POs are accepted from US and Canadian universities.

 

How fast will you ship?
  • We can ship within a few days to two weeks. Shipping time depends on the current demand for our instruments. Members of our sales team will be able to offer current delivery estimates.

 

Will my instrument be insured during shipping?
  • All instruments shipped within the USA and internationally are fuly insured. This applies as long as we are the shipper and handle shipping arrangements.
  • If the buyer handles shipping, then shipping insurance responsibility falls to the buyer; we highly advise that the buyer obtain shipping insurance from their carrier.

 

How do you pack? Have you packed and shipped Agilent 1260 Infinity ll LC System Instruments in the past? Do you ship Internationally?

Packing

  • Most larger instruments ship in fuly enclosed ISPM15-certified wooden crates with proper padding underneath, and the sides have moving components braced.
  • Accessories are packed safely in boxes with padding and then safely packed inside the crate.
  • We may not use a crate for local deliveries to save you money *if delivered by us.
  • We often use “tilt’ & “shock” indicators on the crates to ensure the crate has not been excessively tilted and dropped where equipment may suffer damage.
  • Photos are taken during the packing process to make sure nothing is missed.

USA/Canada Shipping

  • Within the US and Canada, we will ship via selected freight carriers. We do not use low-price/high-damage carriers as we want the equipment to get safely to you.

International Shipping

  • Internationally, we will only ship via Air Freight or Air Parcel (such as UPS or DHL), which provides reliability, no exposure to Ocean weather, and timely delivery.
    We have extensive experience packing and shipping fragile instruments globally.

Our experience and process

  • We have safely packed and shipped thousands of sensitive analytical instruments.

 

How much will I save buying it pre-owned, and is it worth it?

A lot…and it is undoubtedly worth it, and here is why. Feel free to ask for feedback from hundreds of customers who bought from us.

 

  • You will pay less than half vs. buying a new instrument. Why not spend leftover funds on another instrument for your lab?
  • You will get our standard warranty, plus, when available, an option to obtain an extended warranty agreement.
  • Know that your instrument was tested and working the day it left our facility and is covered if there are faults.
  • Get extra peace of mind by adding an extended warranty or service agreement when such an option is available.

 

Sustainability
  • Well, this one is easy: buying a pre-owned instrument is great for the planet; you are reducing unnecessary waste, CO2 output, and water use that would be used during the manufacturing process.

 

I have more questions; I want to receive a formal quote.

Absolutely! Please give us a call (1-617-397-3486) or complete this form to get your questions answered or receive a formal Quote.

 

 

Safe Shipping
From Small Packages to Large Freight
International Shipping
Happy customers all around the world
Warranty
60-days
Registered Vendor To
Many US Colleges, Universities and Fortune 500 Companies