Brand: Waters
Product Code: 52448
Number of solvents: four solvents; operating flow rate range: 0.010 to 4.000 mL/min, in 0.001-mL increments
Labware compatibility: (2x) 96- or 384-well plates, other options
Injection volume range: 0.1 to 50.0 uL, in 0.1-uL increments; 10-uL loop
Column compartment temperature range: 4 to 90 DegC settable in 0.1 DegC increments
PDA detector wavelength range: 190 to 800 nm
Labware compatibility: (2x) 96- or 384-well plates, other options
Injection volume range: 0.1 to 50.0 uL, in 0.1-uL increments; 10-uL loop
Column compartment temperature range: 4 to 90 DegC settable in 0.1 DegC increments
PDA detector wavelength range: 190 to 800 nm
$18,995.00
Brand: Waters
Product Code: 53531
Number of solvents: up to four solvents in any combination
Unit modules: e2695 separations module w/SHC, column heater/cooler, 2998 PDA detector
Number of sample vials: 120 vials, in five carousels of 24 vials each
Wavelength Range 2998 PDA Detector: 190 - 800 nm
Maximum operating pressure: up to 5000 psi
Unit modules: e2695 separations module w/SHC, column heater/cooler, 2998 PDA detector
Number of sample vials: 120 vials, in five carousels of 24 vials each
Wavelength Range 2998 PDA Detector: 190 - 800 nm
Maximum operating pressure: up to 5000 psi
$0.00
Brand: Waters
Product Code: 52140
Number of solvents: up to four solvents in any combination
Unit modules: Quaternary solvent manager, Sample manager-FTN, column manager, TUV detector, QDa detector
Labware Compatibility: (2x) 96- or 384-well plates, other options
Wavelength Range TUV Detector: 190 - 700 nm; Mass range QDA Detector: 30 - 1250 m/z
Maximum operating pressure: up to 15,000 psi
Unit modules: Quaternary solvent manager, Sample manager-FTN, column manager, TUV detector, QDa detector
Labware Compatibility: (2x) 96- or 384-well plates, other options
Wavelength Range TUV Detector: 190 - 700 nm; Mass range QDA Detector: 30 - 1250 m/z
Maximum operating pressure: up to 15,000 psi
$0.00
Brand: Waters
Product Code: 53546
Number of solvents: four solvents; operating flow rate range: 0.010 to 4.000 mL/min, in 0.001-mL increments
Labware compatibility: (2x) 96- or 384-well plates, other options
Injection volume range: 0.1 to 50.0 uL, in 0.1-uL increments; 10-uL loop
Column compartment temperature range: 4 to 90 DegC settable in 0.1 DegC increments
PDA detector wavelength range: 190 to 800 nm; Mass range QDA Detector: 30 - 1250 m/z
Labware compatibility: (2x) 96- or 384-well plates, other options
Injection volume range: 0.1 to 50.0 uL, in 0.1-uL increments; 10-uL loop
Column compartment temperature range: 4 to 90 DegC settable in 0.1 DegC increments
PDA detector wavelength range: 190 to 800 nm; Mass range QDA Detector: 30 - 1250 m/z