Detector modules: Variable Wavelength, Refractive Index, MALS, ViscoStar Detector Flow range: 0.2 to 10 mL/min Injection range: 0.1-100 uL Pump type: isocratic System pressure operating range: up to 600 bar
Detector modules: Variable Wavelength & Refractive Index Detectors Flow range: 0.2 to 10 mL/min Injection range: 0.1-100 uL Pump type: isocratic System pressure operating range: up to 600 bar
Number of solvents: four solvents; operating flow rate range: 0.010 to 4.000 mL/min, in 0.001-mL increments Labware compatibility: (2x) 96- or 384-well plates, other options Injection volume range: 0.1 to 50.0 uL, in 0.1-uL increments; 10-uL loop Column compartment temperature range: 4 to 90 DegC settable in 0.1 DegC increments PDA detector wavelength range: 190 to 800 nm; Mass range QDA Detector: 30 - 1250 m/z
Detector modules: Fluorescence detector, Mass selective detector Flow range: 0.001 – 10 mL/min Injection range: 0.1 – 100 ul Pump type: quaternary System pressure operating range: up to 600 bar
Number of solvents: up to four solvents in any combination Unit modules: e2695 separations module w/SHC, column heater/cooler, 2998 PDA detector Number of sample vials: 120 vials, in five carousels of 24 vials each Wavelength Range 2998 PDA Detector: 190 - 800 nm Maximum operating pressure: up to 5000 psi
Number of solvents: four solvents; operating flow rate range: 0.010 to 4.000 mL/min, in 0.001-mL increments Labware compatibility: (2x) 96- or 384-well plates, other options Injection volume range: 0.1 to 50.0 uL, in 0.1-uL increments; 10-uL loop Column compartment temperature range: 4 to 90 DegC settable in 0.1 DegC increments PDA detector wavelength range: 190 to 800 nm
MicroDAWN MALS Detector & MicroOptilab RI Detectors Molar Mass Range: 200 Da to 10 MDa (proteins) or 1 MDa (linear polymers) MALS Detectors: high-gain, high dynamic range photodiodes at 3 detection angles Laser Wavelength: 659 nm ± 4 nm Absolute Refractive Index range (RIU): 1.2 to 1.8
Range (RIU): -0.0047 to +0.0047 Absolute Refractive Index range (RIU): 1.2 to 1.8 Fluidics band broadening: <12uL Light source: 660 nm Temperature control range: 4DegC to 65DegC
Number of Solvents: up to 4; binary pump type Unit modules: ELS Detector, Column Manager, Sample Manager, Binary Solvent Manager Labware Compatibility: (2x) 96- or 384-well plates Column temperature control 5.0 DegC above ambient to 90.0 DegC settable in 0.1 DegC increments Acquity UPLC ELS detector with nebulizer
Injection volume range: 0.1 to 50 uL Accuracy (aspiration): ±0.2 uL Number of sample plates: any (2) of the 96 and 384 microtiter plates (other options possible) Sample compartment: 4 to 40 DegC, settable in 0.1 DegC increments Temperature accuracy: ±0.5 DegC; stability: ±1.0 DegC at sensor
Number of solvents: up to four solvents in any combination Solvent degassing: integrated vacuum degassing, four chambers Gradient formation: low-pressure mixing, quaternary gradient Gradient profiles: 11 gradient curves Primary check valve: intelligent Intake Valve (i2 Valve)
Wavelength range: Ex.:200 to 890 nm; Em.: 210 to 900 nm Measurement range: 0.001 to 10,000 EU Data acquisition: up to 80 Hz Flow cell design: axially illuminated, cell volume: <2 uL Pressure limit: 500 psi
Number of plates: two plates of 96 and 384 microtiter plates / 48 position vial plates / micro-centrifuge tubes /24 position micro-centrifuge tube plates Maximum sample capacity: 768 in two 384-well plates Injection volume range: 0.1 to 50.0 uL, in 0.1 uL increments, partial or full loop mode Sample delivery precision (full loop injection mode): < 0.3% RSD, full loop, standard 10-uL loop (default wash/purge conditions) Sample temperature control: 4DegC - 40DegC, settable in 0.1 DegC increments (at an ambient temperature of 25DegC)
Column capacity: Single column, up to 150 mm in length, up to 4.6 mm internal diameter (I.D.) Column compartment temperature range: 5-90DegC, settable in 0.1DegC increments Column compartment temperature accuracy: ±0.5 DegC at the sensor Column compartment temperature stability ±0.3 DegC at the sensor Solvent conditioning: active pre-heating
Type: GPC Detector Stack Appliaction: Analysis of polymers, peptides, proteins and other amino acid chains. MALS Detector Molar Mass range: 200 Da to 1 GDa Differential Refractive Index Range (RIU): -0.0047 to +0.0047 Differential Viscosity Sensitivity: 0.1 μg of 100 kDa polystyrene in THF at 1 mL/min, under typical GPC conditions
Type: GPC Detector Stack Appliaction: Analysis of polymers, peptides, proteins and other amino acid chains. MALS Detector Molar Mass range: 200 Da to 1 GDa Molecular Size Range (Rh, with WyattQELS DLS module): in flow mode: 0.5 nm to 300 nm; In batch mode: 0.5 nm to 1 um Differential Viscosity Sensitivity: 0.1 μg of 100 kDa polystyrene in THF at 1 mL/min, under typical GPC conditions
RhВ from 0.2 nm - 1000 nm Temperature range: -10 °C to +120 °C Molecular weight: 300 Da to 1 MDa Turbidity from 1 to 80 NTU SLS and DLS detection channels; Laser wavelength: 658 nm
Injection volume range: 50-ul loop standard; 1,2,5,10,20,100,250-ul loops available Temperature control: 0.1 to 25.0 C, in 0.1C increments Digestion Column heater: Accommodates one column up to 50mm length Digestion column temp control: 10.0C above HDX chamber temperature to 45.0C in0.1C increments