Categories

Electrochemistry

Display: List /Grid
Show:
Sort By:
Axon MultiClamp 700A Amplifier Patch Clamp w/ (2) CV-7A Headstages Pred 700B Unit2
$3,750.00

Agilent 2100 Bioanalyzer G2938B ChipReader
Agilent 2100 Bioanalyzer G2938B ChipReader
Application: Electrophoresis
Sample Size: 1-4uL
Laser Excitation: 470nm and 630nm
Emission Detection: 525nm and 680nm
Recommended Dyes: Calcein, Cell Tracker green, GFP, SYTO16, CBNF, APC, Cy5 or Alexa 647
$5,295.00

Axon MultiClamp 700A Amplifier Patch Clamp with single CV-7A Headstage
$2,795.00

Bio-Rad Experion Electrophoresis Station
Bio-Rad Experion Electrophoresis Station
Laser: Photodiode, 635nm excitation
Detector: Photoemission, 685nm emission
Electrode Wires: 90% platinum, 10% iridium alloy, 0.5mm diameter
$1,495.00

A-M Systems 3600 Microelectrode AC Amplifier 16-Channel SOLDOUTA-M Systems 3600 Microelectrode AC Amplifier 16-Channel SOLDOUT
A-M Systems 3600 Microelectrode AC Amplifier 16-Channel SOLDOUT
High Pass Filter Cut-Off Frequencies (Hz): 0.3, 1.0, 3.0, 10.0, 30.0, 100, 300, 500; Cut-Off Rate: 40dB / decade
Low Pass Filter Cut-Off Frequencies (kHz): 0.1, 0.3, 0.5, 1.0, 3.0, 5.0, 10.0, 20.0; Cut-Off Rate: 40dB / decade
Input Offset Voltage, MaximumStim/Record Headstage 1VRecord Only Headstage 2V (AC), or 100mV DC
Gain 10, 20, 50, 100, 200, 500, 1,000, 2,000, 5,000, 10,000, 20,000
Maximum current is 20mA With a +/- 10V voltage range

A-M Systems 3600 Microelectrode AC Amplifier 16-Channel Unit 2 SOLDOUTA-M Systems 3600 Microelectrode AC Amplifier 16-Channel Unit 2 SOLDOUT
A-M Systems 3600 Microelectrode AC Amplifier 16-Channel Unit 2 SOLDOUT
High Pass Filter Cut-Off Frequencies (Hz): 0.3, 1.0, 3.0, 10.0, 30.0, 100, 300, 500; Cut-Off Rate: 40dB / decade
Low Pass Filter Cut-Off Frequencies (kHz): 0.1, 0.3, 0.5, 1.0, 3.0, 5.0, 10.0, 20.0; Cut-Off Rate: 40dB / decade
Input Offset Voltage, MaximumStim/Record Headstage 1VRecord Only Headstage 2V (AC), or 100mV DC
Gain 10, 20, 50, 100, 200, 500, 1,000, 2,000, 5,000, 10,000, 20,000
Maximum current is 20mA With a +/- 10V voltage range.

Agilent 2100 Bioanalyzer G2938A ChipReader for Electrophoresis SOLDOUTAgilent 2100 Bioanalyzer G2938A ChipReader for Electrophoresis SOLDOUT
Agilent 2100 Bioanalyzer G2938A ChipReader for Electrophoresis SOLDOUT
Application: Electrophoresis
Sample size: 1-4uL
Laser Excitation: 470 nm and 630 nm
Emission detection: 525 nm and 680 nm
Recommended dyes: Calcein, Cell Tracker green, GFP, SYTO16, CBNF, APC, Cy5 or Alexa 647

Agilent 2100 Bioanalyzer G2938B Pred G2938C SOLDOUTAgilent 2100 Bioanalyzer G2938B Pred G2938C SOLDOUT
Agilent 2100 Bioanalyzer G2938B Pred G2938C SOLDOUT
Application: electrophoresis
Sample Size: 1-4uL
Laser Excitation: 470nm and 630nm
Emission Detection: 525nm and 680nm
Recommended Dyes: calcein, cell tracker green, GFP, SYTO16, CBNF, APC, Cy5 or Alexa 647

Agilent 2100 Bioanalyzer G2938C SOLDOUTAgilent 2100 Bioanalyzer G2938C SOLDOUT
Agilent 2100 Bioanalyzer G2938C SOLDOUT
Application: Electrophoresis
Sample size: 1-4uL
Laser Excitation: 470 nm and 630 nm
Emission detection: 525 nm and 680 nm
Recommended dyes: Calcein, Cell Tracker green, GFP, SYTO16, CBNF, APC, Cy5 or Alexa 647

Agilent 2100 Bioanalyzer G2939A Unit2 SOLDOUTAgilent 2100 Bioanalyzer G2939A Unit2 SOLDOUT
Agilent 2100 Bioanalyzer G2939A Unit2 SOLDOUT
Application: Electrophoresis
Sample Size: 1-4uL
Laser Excitation: 470nm and 630nm
Emission Detection: 525nm and 680nm
Recommended Dyes: Calcein, Cell Tracker green, GFP, SYTO16, CBNF, APC, Cy5 or Alexa 647

ALA MCS Roboocyte Electrophysiology Workstation w/ Narishige Pred. to Roboocyte2 SOLDOUTALA MCS Roboocyte Electrophysiology Workstation w/ Narishige Pred. to Roboocyte2 SOLDOUT
ALA MCS Roboocyte Electrophysiology Workstation w/ Narishige Pred. to Roboocyte2 SOLDOUT
Sample labware: 96 well microplate
Injection pressure: 0 to 3 bar
Positioning Accuracy: 20um in x/y and 33um in z
Dimensions: 390 x 360 x 500 mm

Axon Axopatch 200A Patch Clamp Amplifier w/ CV201AU Pred 200B SOLDOUTAxon Axopatch 200A Patch Clamp Amplifier w/ CV201AU Pred 200B SOLDOUT

Axon Axopatch 200B Integrated Patch Clamp SOLDOUTAxon Axopatch 200B Integrated Patch Clamp SOLDOUT
Axon Axopatch 200B Integrated Patch Clamp SOLDOUT
Amplifier Type - Patch Clamp
Application - Basic Ion Channel Research, Cell Pathway Analysis, Disease Research, Safety Assessment
Number of Head Stages included - None
Software Included - None

Axon Axopatch 200B Patch Clamp Amplifier w/ CV203BU SOLDOUTAxon Axopatch 200B Patch Clamp Amplifier w/ CV203BU SOLDOUT

Axon Axopatch 200B Patch Clamp Amplifier w/ Digidata 1322A & pClamp 10 Software SOLDOUTAxon Axopatch 200B Patch Clamp Amplifier w/ Digidata 1322A & pClamp 10 Software SOLDOUT
Axon Axopatch 200B Patch Clamp Amplifier w/ Digidata 1322A & pClamp 10 Software SOLDOUT
pClamp10 software and the hardware dongle key
Incorporates capacitor-feedback technology
Active headstage cooling for single-channel recording

Axon Instruments MultiClamp 700A Current Voltage Clamp with two CV-7 Headstages SOLDOUTAxon Instruments MultiClamp 700A Current Voltage Clamp with two CV-7 Headstages SOLDOUT
Axon Instruments MultiClamp 700A Current Voltage Clamp with two CV-7 Headstages SOLDOUT
Software Control alows smart features
Automatic capacitance compensation
Automatic bridge balance
2 Channel

Axon MultiClamp 700A Amplifier Patch Clamp w/ CV-7A Headstage Pred 700B Unit3 SOLDOUTAxon MultiClamp 700A Amplifier Patch Clamp w/ CV-7A Headstage Pred 700B Unit3 SOLDOUT

Axon MultiClamp 700A Amplifier Patch Clamp w/ CV-7A Headstage Pred 700B Unit4 SOLDOUTAxon MultiClamp 700A Amplifier Patch Clamp w/ CV-7A Headstage Pred 700B Unit4 SOLDOUT

Axon MultiClamp 700A Amplifier PatchClamp w/ (2) CV-7A Headstage Pre 700B SOLDOUTAxon MultiClamp 700A Amplifier PatchClamp w/ (2) CV-7A Headstage Pre 700B SOLDOUT

Axon MultiClamp 700A Amplifier PatchClamp w/ CV-7A Headstage Pred 700B SOLDOUTAxon MultiClamp 700A Amplifier PatchClamp w/ CV-7A Headstage Pred 700B SOLDOUT

Axon MultiClamp 700A Amplifier PatchClamp w/ CV-7A Headstage Pred 700B SOLDOUTAxon MultiClamp 700A Amplifier PatchClamp w/ CV-7A Headstage Pred 700B SOLDOUT
Axon MultiClamp 700A Amplifier PatchClamp w/ CV-7A Headstage Pred 700B SOLDOUT
Amplifier Type: Patch Clamp
Application: Basic Ion Channel Research, Cell Pathway Analysis, Disease Research, Safety Assessment
Number of Head Stages included: (1) Headstage CV-7B
Software Included: MultiClamp 700A Commander software ver1.3

Axon MultiClamp 700B Patch Clamp Amplifier with CV-7B Headstage SOLDOUTAxon MultiClamp 700B Patch Clamp Amplifier with CV-7B Headstage SOLDOUT
Axon MultiClamp 700B Patch Clamp Amplifier with CV-7B Headstage SOLDOUT
Seal Test Amplitudes / Pulse Amplitudes: 0 to +/-1 V at electrode
Seal Test Frequency: from 2–1000 Hz
Pulse Duration: from 0.1–500 ms
Channels: 2 (sharing a common ground)

Bio-Rad Gene Pulser Xcell Eukaryotic Electroporation System 1652661 SOLDOUTBio-Rad Gene Pulser Xcell Eukaryotic Electroporation System 1652661 SOLDOUT
Bio-Rad Gene Pulser Xcell Eukaryotic Electroporation System 1652661 SOLDOUT
Outputs Waveform: exponential decay or square wave
Voltage: 10–3000V
Capacitance 10–500V: 25–3,275 uF in 25 uF increments, 500–3000V: 10, 25, 50 uF
Resistance (parallel): 50–1000 Om in 50 Om increments, plus infinity
Sample Resistance: 20 Om minimum @10–2500V, 600 Om minimum @2500–3000 V

Bio-Rad Gene-Pulser-Xcell Electroporation System w/ Shock-Pod CE Module 617BR1 SOLDOUTBio-Rad Gene-Pulser-Xcell Electroporation System w/ Shock-Pod CE Module 617BR1 SOLDOUT

GE Ettan IPGphor 3 IEF Isoelectric Focusing Protein 2-D Electrophoresis SOLDOUTGE Ettan IPGphor 3 IEF Isoelectric Focusing Protein 2-D Electrophoresis SOLDOUT
GE Ettan IPGphor 3 IEF Isoelectric Focusing Protein 2-D Electrophoresis SOLDOUT
Electrophoresis Type: isoelectric focusing and 2-dimension
Chips Available: protein
Samples: from 1 to 12 IPG strips
Dimensions(WxHxD): 278 x 160 x 471mm


Boston Industries, Inc. © 2019