Brand: ACEA
Product Code: 62249
Optics: (3) VBR Lasers, (13) Colors, (15) Detector
Fluorescence threshold sensitivity: FITC <75 MESF, PE <50 MESF, APC <20 MESF
Sample acquisition rate: 35,000 events/second
Sample flow rate: 5 to 120 uL/min
Automatic sample loading with NovaSampler
Fluorescence threshold sensitivity: FITC <75 MESF, PE <50 MESF, APC <20 MESF
Sample acquisition rate: 35,000 events/second
Sample flow rate: 5 to 120 uL/min
Automatic sample loading with NovaSampler
$24,995.00
Brand: ACEA
Product Code: 61801
Sampling rate: 250 Hz for fast impedance readout
Accuracy: ±(1.5% + 1 Ω), repeatability 0.8%
Pulse range: –2.5 V to +2.5 V, 0.01–125 Hz
Waveforms: Rect., Tri., Sine, Trap., Exp. Decay
Electrical Interface: 3xCardioECR 48 + 3xCardio 96
Accuracy: ±(1.5% + 1 Ω), repeatability 0.8%
Pulse range: –2.5 V to +2.5 V, 0.01–125 Hz
Waveforms: Rect., Tri., Sine, Trap., Exp. Decay
Electrical Interface: 3xCardioECR 48 + 3xCardio 96
$22,995.00
Brand: ACEA
Product Code: SM101359
Sampling Format: 6 x 96 E Plates
Output test signal: 22 mV rms ±20% at 10, 25, and 50 kHz
Impedance measure accuracy: ±(1% + 1.5 Ω)
Impedance measurement repeatability: 0.8%
Impedance dynamic range: 10 to 5 kΩ
Output test signal: 22 mV rms ±20% at 10, 25, and 50 kHz
Impedance measure accuracy: ±(1% + 1.5 Ω)
Impedance measurement repeatability: 0.8%
Impedance dynamic range: 10 to 5 kΩ
$17,995.00
Brand: ACEA
Product Code: 63087
Electrical Input: +5 V, -5 V, 1 W max
Electrical Interface: one E-Plate 96
Measurement Rate: <10 s per E-Plate 96
Impedance Accuracy: ± (1.5% + 1 Ω), Repeatability 0.8%
Output Test Signal: 22 mV rms ±20% at 10, 25, 50 kHz
Electrical Interface: one E-Plate 96
Measurement Rate: <10 s per E-Plate 96
Impedance Accuracy: ± (1.5% + 1 Ω), Repeatability 0.8%
Output Test Signal: 22 mV rms ±20% at 10, 25, 50 kHz
$14,995.00
Brand: ACEA
Product Code: SM100005
Electrical input: +5 VDC, 1 W max
Electronic switch resistance: 2 to 5 Ω
Capacity: 3 x E-Plate 16 devices or 3 x CIM-Plate devices
Output test signal: 22 mV rms ±(2% +5 mVrms) at 10, 25, and 50 kHz
Impedance dynamic range: 10 to 5 kΩ
Electronic switch resistance: 2 to 5 Ω
Capacity: 3 x E-Plate 16 devices or 3 x CIM-Plate devices
Output test signal: 22 mV rms ±(2% +5 mVrms) at 10, 25, and 50 kHz
Impedance dynamic range: 10 to 5 kΩ
$8,795.00
Brand: ACEA
Product Code: SM101533
Electrical input: +6 VDC, 1.5 W max
FP band-pass filter: 1 Hz to 4.5 kHz
Stimulation voltage range: –2.5 to +2.5V
Stimulation time resolution: 10 μs
Electrical interface: one E-Plate CardioECR 48
FP band-pass filter: 1 Hz to 4.5 kHz
Stimulation voltage range: –2.5 to +2.5V
Stimulation time resolution: 10 μs
Electrical interface: one E-Plate CardioECR 48
$12,995.00
Brand: ACEA
Product Code: 56593
Sampling Format: 6 x 96 E Plates
Output test signal: 22 mV rms ±20% at 10, 25, and 50 kHz
Impedance measure accuracy: ±(1% + 1.5 Ω)
Impedance measurement repeatability: 0.8%
Impedance dynamic range: 10 to 5 kΩ
Output test signal: 22 mV rms ±20% at 10, 25, and 50 kHz
Impedance measure accuracy: ±(1% + 1.5 Ω)
Impedance measurement repeatability: 0.8%
Impedance dynamic range: 10 to 5 kΩ
$0.00
Brand: ACEA
Product Code: 49826
Pre-Owned
Sampling Format: 6 x 96 E Plates
Output test signal: 22 mV rms ±20% at 10, 25, and 50 kHz
Impedance measure accuracy: ±(1% + 1.5 Ω)
Impedance measurement repeatability: 0.8%
Sampling Format: 6 x 96 E Plates
Output test signal: 22 mV rms ±20% at 10, 25, and 50 kHz
Impedance measure accuracy: ±(1% + 1.5 Ω)
Impedance measurement repeatability: 0.8%
$0.00
Brand: ACEA
Product Code: 58112
Sampling Format: 6 x 96 E Plates
Output test signal: 22 mV rms ±20% at 10, 25, and 50 kHz
Impedance measure accuracy: ±(1% + 1.5 Ω)
Impedance measurement repeatability: 0.8%
Impedance dynamic range: 10 to 5 kΩ
Output test signal: 22 mV rms ±20% at 10, 25, and 50 kHz
Impedance measure accuracy: ±(1% + 1.5 Ω)
Impedance measurement repeatability: 0.8%
Impedance dynamic range: 10 to 5 kΩ
$0.00
Brand: ACEA
Product Code: 42241
Sampling Format: 3 x 16 well plates
Measurement Applications: Adhesion, Apoptosis, Cell Characterization, Cytotoxicity, Immune Cell Killing, Proliferation, Receptor Signaling, Virus Cytopathic Effects
Test Signal: 22 mV rms +/-20% with max. 5 mV DC offset at 10, 25 and 50 kHz
Environment: Temperature, +15C to +40C; relative humidity, 98% maximum without condensation
Resistor Values: 37.4, 64.9, 91.0, 115.0 Om, +/-0.5%
Measurement Applications: Adhesion, Apoptosis, Cell Characterization, Cytotoxicity, Immune Cell Killing, Proliferation, Receptor Signaling, Virus Cytopathic Effects
Test Signal: 22 mV rms +/-20% with max. 5 mV DC offset at 10, 25 and 50 kHz
Environment: Temperature, +15C to +40C; relative humidity, 98% maximum without condensation
Resistor Values: 37.4, 64.9, 91.0, 115.0 Om, +/-0.5%
$0.00
Brand: ACEA
Product Code: 49289
Sampling Format: 3 x 16 well plates
Measurement Applications: Adhesion, Apoptosis, Cell Characterization, Cytotoxicity, Immune Cell Killing, Proliferation, Receptor Signaling, Virus Cytopathic Effects
Test Signal: 22 mV rms +/-20% with max. 5 mV DC offset at 10, 25 and 50 kHz
Environment: Temperature, +15C to +40C; relative humidity, 98% maximum without condensation
Resistor Values: 37.4, 64.9, 91.0, 115.0 Om, +/-0.5%
Measurement Applications: Adhesion, Apoptosis, Cell Characterization, Cytotoxicity, Immune Cell Killing, Proliferation, Receptor Signaling, Virus Cytopathic Effects
Test Signal: 22 mV rms +/-20% with max. 5 mV DC offset at 10, 25 and 50 kHz
Environment: Temperature, +15C to +40C; relative humidity, 98% maximum without condensation
Resistor Values: 37.4, 64.9, 91.0, 115.0 Om, +/-0.5%
$0.00
Brand: ACEA
Product Code: 49469
Sampling Format: 6 x 96 well plate
Measurement Applications: Cardiomyocyte Beating, Compound Evaluation. Detect drug-induced changes, cardiotoxicity and cell contractility in real time
Temperature: +15 to +40C, relative humidity: 98% maximum without condensation
Monitor cells under physiological conditions within standard CO2 incubators
Measurement Applications: Cardiomyocyte Beating, Compound Evaluation. Detect drug-induced changes, cardiotoxicity and cell contractility in real time
Temperature: +15 to +40C, relative humidity: 98% maximum without condensation
Monitor cells under physiological conditions within standard CO2 incubators
$0.00
Brand: ACEA
Product Code: 58081
Optics: (3) VBR Lasers, (13) Colors, (15) Detector
Fluorescence threshold sensitivity: FITC <75 MESF, PE <50 MESF, APC <20 MESF
Sample acquisition rate: 35,000 events/second
Sample flow rate: 5 to 120 uL/min
Automatic sample loading with NovaSampler Pro
Fluorescence threshold sensitivity: FITC <75 MESF, PE <50 MESF, APC <20 MESF
Sample acquisition rate: 35,000 events/second
Sample flow rate: 5 to 120 uL/min
Automatic sample loading with NovaSampler Pro
$0.00
Brand: ACEA
Product Code: 42676
(2) Lasers: 488nm (Blue), 640nm (Red)
(5) Detectors: 488/10nm, 530/30nm, 585/40nm, 675/30nm, 780/60nm
Example Applications: Apoptosis Assay Immunophenotyping Intracellular Protein Detection Cell Cycle Analysis Cell Proliferation
Sample Handling: 96 well plate (U-bottom, flat bottom, V-bottom) 24 well plate 24 tube rack 48 well plate
Flowrate: 5 - 120 uL/min Sample Volume: 10 uL - 5mL Particle Size: 0.2 - 50 um
(5) Detectors: 488/10nm, 530/30nm, 585/40nm, 675/30nm, 780/60nm
Example Applications: Apoptosis Assay Immunophenotyping Intracellular Protein Detection Cell Cycle Analysis Cell Proliferation
Sample Handling: 96 well plate (U-bottom, flat bottom, V-bottom) 24 well plate 24 tube rack 48 well plate
Flowrate: 5 - 120 uL/min Sample Volume: 10 uL - 5mL Particle Size: 0.2 - 50 um
$0.00
Showing 1 to 15 of 15 (1 Pages)