Reaction Volume: 5-20uL for 384-well block Maximum Ramp Rate 384-well: 6C/sec Average Sample Ramp Rate 384-well 2.92C/sec Temperature Uniformity: 0.4C; Temperature Range 4-99.9C Dimensions (D x W x H) and weight 52.5 x 33.8 x 54.7 cm; 38 kg
Reaction Volume: 5-20uL for 384-well block Maximum Ramp Rate 384-well: 6C/sec Average Sample Ramp Rate 384-well 2.92C/sec Temperature Uniformity: 0.4C; Temperature Range 4-99.9C Dimensions (D x W x H) and weight 52.5 x 33.8 x 54.7 cm; 38 kg
Block Type: NON-Interchangeable Format: 96-well plate Detection Range 96-well: 450-680nm/500-730nm Temperature Range: 4-100C; Temperature Uniformity: +/-0.4C Dimensions, Weight: 27 x 50 x 40 cm (W x D x H), <26 kg
Run Time: ~35 min for 384-well, ~30 min for 0.2 mL 96-well and 0.1 mL Fast 96-well (using Applied Biosystems Fast Master Mix) Excitation/Detection Wavelengths: 6 excitation (450–670 nm), 6 emission (500–720 nm) Temperature Uniformity: +/-0.5C, within 30 sec of reaching temperature set point Supported Applications: Standard curve, Comparative Ct , Genotyping, Presence/Absence, HRM, Melt curve
Run Time: <2 hrs/run (Standard Mode), <40 min⁄run (Fast Mode) Temperature Range (Metric): 4-100C Detection Method: SYBR, Primer-Probe Detection Reaction Volume Range: 10-30 ul (Standard curve experiments: 40 ul in standard mode is validated) Optics: 4 emission filters, Blue LED excitation source, photodiode
Block Format: Interchangeable Format: Fast 96-well plate Temperature Range: 4-100C Temperature Uniformity: +/-0.5C Dimensions: 53.3 cm (21 in) (W) x 63.5 cm (25 in) (D) x 64.5 cm (25.4 in) (H)
Block Format: Interchangeable Format: 96-well plate Temperature Range: 4-100C; Temperature Uniformity: +/-0.5C (5) coupled excitation and emission filter channels; (5) color detection Dimensions (WxDxH): 53.3 cm (21 in) x 63.5 cm (25 in) x 64.5 cm (25.4 in)
Block Format: Interchangeable Format: 96-well plate Temperature Range: 4-100C; Temperature Uniformity: +/-0.5C (5) coupled excitation and emission filter channels; (5) color detection Dimensions (WxDxH): 53.3 cm (21 in) x 63.5 cm (25 in) x 64.5 cm (25.4 in)
Block Format: Interchangeable Format: 96-well plate Temperature Range: 4-100C; Temperature Uniformity: +/-0.5C (5) coupled excitation and emission filter channels; (5) color detection Dimensions (WxDxH): 53.3 cm (21 in) x 63.5 cm (25 in) x 64.5 cm (25.4 in)
Block Format: Interchangeable Format: 96-well plate Temperature Range: 4-100C; Temperature Uniformity: +/-0.5C (5) coupled excitation and emission filter channels; (5) color detection Dimensions (WxDxH): 53.3 cm (21 in) x 63.5 cm (25 in) x 64.5 cm (25.4 in)
Reaction Volume Range: 5 - 30uL Sample Format: 96-Well Plates, optimized for 10uL reactions Temperature Range: 4 - 100C Sample ramp rate Fast mode: 3.5°C/sec Multiplex Capability: Multiplex up to five targets per well
Reaction Volume Range: 5 - 30uL Sample Format: 96-Well Plates, optimized for 10uL reactions Temperature Range: 4 - 100C Sample ramp rate Fast mode: 3.5°C/sec Multiplex Capability: Multiplex up to five targets per well
96-plate Run Time: <30min Temperature Range: 4-100C Detectors: CCD camera with halogen lamp excitation Reaction Volumes: 5-30uL Sensitivity: Detection of 1 copy of template in a 20uL reaction for a single reporter TaqMan assay with 99.7% confidence