Brand: Wyatt Technology
Product Code: 67842
Range (RIU): -0.0047 to +0.0047
Absolute Refractive Index range (RIU): 1.2 to 1.8
Fluidics band broadening: <12uL
Light source: 660 nm
Temperature control range: 4DegC to 65DegC
Absolute Refractive Index range (RIU): 1.2 to 1.8
Fluidics band broadening: <12uL
Light source: 660 nm
Temperature control range: 4DegC to 65DegC
$11,995.00
Brand: Wyatt Technology
Product Code: 61488
Range (RIU): -0.0047 to +0.0047
Absolute Refractive Index range (RIU): 1.2 to 1.8
Fluidics band broadening: <12uL
Light source: 658 nm
Temperature control range: 4DegC to 65DegC
Absolute Refractive Index range (RIU): 1.2 to 1.8
Fluidics band broadening: <12uL
Light source: 658 nm
Temperature control range: 4DegC to 65DegC
$0.00
Brand: Wyatt Technology
Product Code: 59847
Range (RIU): -0.0047 to +0.0047
Absolute Refractive Index range (RIU): 1.2 to 1.8
Fluidics band broadening: <12uL
Light source: 658 nm
Temperature control range: 4DegC to 65DegC
Absolute Refractive Index range (RIU): 1.2 to 1.8
Fluidics band broadening: <12uL
Light source: 658 nm
Temperature control range: 4DegC to 65DegC
$0.00
Brand: Wyatt Technology
Product Code: 55097
Range (RIU): -0.0047 to +0.0047
Absolute Refractive Index range (RIU): 1.2 to 1.8
Fluidics band broadening: <12uL
Light source: 660 nm
Temperature control range: 4DegC to 65DegC
Absolute Refractive Index range (RIU): 1.2 to 1.8
Fluidics band broadening: <12uL
Light source: 660 nm
Temperature control range: 4DegC to 65DegC
$0.00
Brand: Wyatt Technology
Product Code: 50629
MALS Detectors: High-gain, high dynamic range photodiodes at 3 detection angles
Auxilary Detectors: Laser monitor for stabilization feedback
Dynamic range: 3,300,00:1
Laser wavelength: 658 nm ± 4 nm
Molar mass range: 200 Da to 10 MDa (proteins) or 1 MDa (linear polymers)
Auxilary Detectors: Laser monitor for stabilization feedback
Dynamic range: 3,300,00:1
Laser wavelength: 658 nm ± 4 nm
Molar mass range: 200 Da to 10 MDa (proteins) or 1 MDa (linear polymers)
$0.00
Brand: Wyatt Technology
Product Code: 55687
MicroDAWN MALS Detector & MicroOptilab RI Detectors
Molar Mass Range: 200 Da to 10 MDa (proteins) or 1 MDa (linear polymers)
MALS Detectors: high-gain, high dynamic range photodiodes at 3 detection angles
Laser Wavelength: 659 nm ± 4 nm
Absolute Refractive Index range (RIU): 1.2 to 1.8
Molar Mass Range: 200 Da to 10 MDa (proteins) or 1 MDa (linear polymers)
MALS Detectors: high-gain, high dynamic range photodiodes at 3 detection angles
Laser Wavelength: 659 nm ± 4 nm
Absolute Refractive Index range (RIU): 1.2 to 1.8
$0.00
Brand: Wyatt Technology
Product Code: 50602
Type: GPC Detector Stack
Appliaction: Analysis of polymers, peptides, proteins and other amino acid chains.
MALS Detector Molar Mass range: 200 Da to 1 GDa
Differential Refractive Index Range (RIU): -0.0047 to +0.0047
Differential Viscosity Sensitivity: 0.1 μg of 100 kDa polystyrene in THF at 1 mL/min, under typical GPC conditions
Appliaction: Analysis of polymers, peptides, proteins and other amino acid chains.
MALS Detector Molar Mass range: 200 Da to 1 GDa
Differential Refractive Index Range (RIU): -0.0047 to +0.0047
Differential Viscosity Sensitivity: 0.1 μg of 100 kDa polystyrene in THF at 1 mL/min, under typical GPC conditions
$0.00
Brand: Wyatt Technology
Product Code: 55098
Type: GPC Detector Stack
Appliaction: Analysis of polymers, peptides, proteins and other amino acid chains.
MALS Detector Molar Mass range: 200 Da to 1 GDa
Molecular Size Range (Rh, with WyattQELS DLS module): in flow mode: 0.5 nm to 300 nm; In batch mode: 0.5 nm to 1 um
Differential Viscosity Sensitivity: 0.1 μg of 100 kDa polystyrene in THF at 1 mL/min, under typical GPC conditions
Appliaction: Analysis of polymers, peptides, proteins and other amino acid chains.
MALS Detector Molar Mass range: 200 Da to 1 GDa
Molecular Size Range (Rh, with WyattQELS DLS module): in flow mode: 0.5 nm to 300 nm; In batch mode: 0.5 nm to 1 um
Differential Viscosity Sensitivity: 0.1 μg of 100 kDa polystyrene in THF at 1 mL/min, under typical GPC conditions
$0.00
Brand: Wyatt Technology
Product Code: 64069
Dynamic light scattering with a size range of 0.5–1000 nm (Rh)
Static light scattering supporting molar masses from 1,000 to 1,000,000 Da
Supported well-plate formats include 96, 384, and 1536 wells
Minimum sample volume of 4 uL depending on plate format
Laser optics include an 830 nm source with programmable power from 10% to 100%
Static light scattering supporting molar masses from 1,000 to 1,000,000 Da
Supported well-plate formats include 96, 384, and 1536 wells
Minimum sample volume of 4 uL depending on plate format
Laser optics include an 830 nm source with programmable power from 10% to 100%
$0.00
Brand: Wyatt Technology
Product Code: 50601
RhВ from 0.2 nm - 1000 nm
Temperature range: -10 °C to +120 °C
Molecular weight: 300 Da to 1 MDa
Turbidity from 1 to 80 NTU
SLS and DLS detection channels; Laser wavelength: 658 nm
Temperature range: -10 °C to +120 °C
Molecular weight: 300 Da to 1 MDa
Turbidity from 1 to 80 NTU
SLS and DLS detection channels; Laser wavelength: 658 nm
$0.00
Brand: Wyatt Technology
Product Code: 61480
Molar mass range: 200 Da – 1 GDa
Size ranges: Rg 10–500 nm, Rh 0.5 nm–1 µm with QELS
Sensitivity: 10 ng polystyrene, 200 ng BSA
Detectors: MALS + integrated WyattQELS DLS
Dynamic range: 3,300,000:1; Laser 661 nm
Size ranges: Rg 10–500 nm, Rh 0.5 nm–1 µm with QELS
Sensitivity: 10 ng polystyrene, 200 ng BSA
Detectors: MALS + integrated WyattQELS DLS
Dynamic range: 3,300,000:1; Laser 661 nm
$0.00
Showing 1 to 11 of 11 (1 Pages)
-250x200w.jpg)
-250x200w.jpg)





-250x200w.jpg)

-250x200w.jpg)