Menu
Your Cart

Revity Perkin Elmer EnVision 2105-0010 Dual Detector Multimode Microplate Reader w/ TRF and AlphaScreen Lasers - AV

Revity Perkin Elmer EnVision 2105-0010 Dual Detector Multimode Microplate Reader w/ TRF and AlphaScreen Lasers - AV
Revity Perkin Elmer EnVision 2105-0010 Dual Detector Multimode Microplate Reader w/ TRF and AlphaScreen Lasers - AV
  • Stock: In Stock
  • Brand: Perkin Elmer
  • Product Code: 52184
  • Condition: Pre-Owned
$26,995.00
CLICKABLE TABS BELOW

Here is a Perkin Elmer EnVision XCite 2105-0010 Dual Detector Multimode Microplate Reader w/ TRF and AlphaScreen Lasers

P/N 2105-0010

Perkin Elmer Lifesciences has recently rebranded as Revity and this model is now called EnVision XCite 2105 Multimode Plate Reader

New configuration like this would be priced around $90,000-$100,000

Predecessor to:
Current model

Condition:
This Perkin Elmer EnVision 2105-0010 Multimode Microplate Reader is in good working condition.

Please see the exact video and photos below.

Testing we performed:
The Perkin Elmer EnVision 2105-0010 Multimode Microplate Reader passed all tests and found to be fully functional:
Tested communication with software: PASSED
Tested absorbance using test plate: PASSED
Tested fluorescence using test plate: PASSED
Tested ultrasensitive luminescence using test plate: PASSED
Tested stacker: PASSED
Tested temperature control: PASSED
Tested barcode readers: PASSED
Tested shaking function: PASSED
Tested TRF laser: PASSED
Tested Alpha screen using custom test plate: PASSED

System consists of:
Perkin Elmer EnVision 2105-0010 Microplate Reader Dual Detector
TRF Light Unit option
Standard AlphaScreen laser option
UltraSensative Luminescence detector option
Plate cooler option
Microplate Stacker w/ (2) stacks (20 or 50 stack option available)
Mirror Module: General bs50/bs50 dual mirror
Absorbance Excitation Filter: Photometric 405/8 filter
Desktop PC with EnVision application
Communication and power cables

Included in addition to above per your preference or needs:

  • One Mirror Module (Inquire with us for mirror modules)
  • Two Filters (Inquire with us for filter options)

 

Note: Additional filters and mirror modules can be purchased and installed upon request. Please inquire with us.


Configuration and Setup: (The instrument is configurable which will affect final specifications and configuration)

 

Model:Perkin Elmer EnVision 2105-0010 Multimode Microplate Reader
Applications:• Cellular Assays
• GPCR Assays
• Reporter Gene Assays
• Enzyme Assays
• Kinase Assays
• Quantification Assays
• AlphaScreen Assays
• AlphaLISA Assays
• LANCE TR-FRET Assays
• DELFIA TRF Assays
• LiteTM Luminescence Assays
• AequoScreen Luminescence Assays
Read types:Kinetic, endpoint, well-area scanning
Detection modes:• Absorbance (ABS)
• Fluorescence intensity (FL)
• Fluorescence polarization (FP)
• Time-resolved fluorescence (TRF)
• Luminescence (LUM)
• AlphaScreen
Wavelength selection:• filter modules
Wavelength range, nm:230-1000nm (filter dependent)
Detectors:•Photodiode (For absorbance reads)
•Photomultiplier tube (PMT) (For all other detection modes)
Light sources:Xenon flash lamp, TRF laser, Alpha-Screen laser
Plate format:All microplate formats up to 1536-well plates (including 96-, 384-well plates)
Plate read time:• 96 wells: 22 seconds
• 384 wells: 27 seconds
• 1536 wells: 36 seconds
Sensitivity:• Absorbance (ABS): range for 96 plate: 0-4 OD; accuracy at 2 OD: < 2%; Precision at 2 OD: < 0.1 %;
• Fluorescence intensity (FL) filter for 96 well:< 4 pM, <0.8 fmol/well, fluorescein, 100 flashes from top
• Fluorescence polarization (FP) for 96 well: < 3 mP, 1nM Fluorescein, 100 flashes
• Luminescence (LUM) for 96 well: < 75 pM, ATP, 1 second
• Time-resolved fluorescence (TRF) for 96 well: < 55 fM, Eu, <11 amol/well, 100 flashes from top
• AlphaScreen for 384 well: < 100 amol
Shaking:• Linear
• Orbital
• Dual orbital
Temperature control:from 2 DegC above ambient to 55 DegC; with a uniformity of +/- 1 DegC.
Data analysis software:EnVision software ver1.14
Features:• Two detectors enabling simultaneous dual wavelength reading
• Top and bottom reading
• Plate height sensor
• PlateID Barcode readers:
- Plate Barcode Reader - short side of the plate
- Plate Barcode Reader - long side of the plate
• General dual emission optical module (not including filters)
• Stacker compatible
Options:• Filters and mirror modules (can be added upon request)
• Stacker for 20 or 50 plates (ask about the options)
• UltraSensative Luminescence (installed)
• TRF laser (installed)
• Standard AlphaScreen - laser light source and plate cooler unit (installed)
• HTS AlphaScreen - laser light source and plate cooler unit (can be added upon request)
• Temperature control (installed)
• Dispenser (can be added upon request)
Power requirements:100 – 240 Volts AC. 50/60 Hz
Weight:110.2 lbs (50 kg)
Dimensions (W x D x H):16.5” x 21.7” x 22.8”
(42 x 55 x 58 cm)

 


Video Description:
The video below gives an overview of the Perkin Elmer EnVision 2105-0010 Multimode Microplate Reader, and also demonstrates its functionality.

Documentation:

Datasheet: Perkin Elmer EnVision 2105-0010 Multimode Microplate Reader

Brochure: Perkin Elmer EnVision 2105-0010 Multimode Microplate Reader

Manual: Perkin-EnVision-2104 Reader Manual (Operation is the same as 2105)

This item will ship via freight. Please contact us with your zip code to obtain a shipping quote.

*ME* Medium Crate
365#

Please do not hesitate to contact us if you have any questions.

All equipment warranty request must have a support case opened within the 60-day warranty period.
To open a support case, please send an email to [email protected] or call (508)974-4896.
Please provide your name, contact information, quotation/invoice number and a brief description of the issue that you are experiencing.
Phone and/or Email support will be provided prior to scheduling a return.
Please see the link below for our detailed warranty statement.
Customers must retain all original shipping materials during the warranty period.

Every instrument has unique packing and shipping needs. Few instruments can be safely shipped via Pacel, and most require the safety of a well-built crate.

Here we are showing you our standard packing process  

      1. All items are different, but they all follow the same principle when packaging.

      2. Start with a well-constructed crate

A well-constructed crate would consist of 1/2” to 5/8” Plywood with framing. We generally purchase our crates from a third party who specializes in custom crates.

      3. You always want the Instrument to not be directly on the wood deck of the crate. This is done by placing it on foam, inside of the crate. We use 2” 1.7 lb. density foam which works great. It provides cushioning and enough firmness to support the Instrument.

      4. The next step is to make sure there is nothing on the deck of the Instrument and the Head/ Arm is secured. In some cases there will be multiple arms to secure but for this example there is only one. The reason for this is so there is no free movement during transit which could cause serious damage to the Instrument.

      5. The next step is to make sure your Instrument is covered in either a pallet bag or shrink wrap so no dust or foreign object will get into the crate.

      6. The next step is to secure the instrument inside the crate by bracing. We use a method of 2x4’s which have 1” foam shrink wrapped to them so no piece of wood touches the actual instrument.

      7. Final step is to photograph everything inside the crate and then seal it with screws.

 

Safe Shipping
From Small Packages to Large Freight
International Shipping
Happy customers all around the world
Warranty
60-days
Registered Vendor To
Many US Colleges, Universities and Fortune 500 Companies