Menu
Your Cart

Agilent BioTek 405 Select TS Microplate Washer 405TSUVS w/ BioStack Stacker - AV

Agilent BioTek 405 Select TS Microplate Washer 405TSUVS w/ BioStack Stacker - AV
Agilent BioTek 405 Select TS Microplate Washer 405TSUVS w/ BioStack Stacker - AV
  • Stock: In Stock
  • Brand: Biotek Bio-Tek
  • Product Code: 50911
  • Condition: Pre-Owned
$10,995.00
CLICKABLE TABS BELOW

Here is an Agilent BioTek 405 Select TS Microplate Washer 405TSUVS with BioStack Stacker

Predecessor to:
Current model

Condition:
This BioTek 405 Select TS Microplate Washer 405TSUVS is in good working condition.

Please see the exact video and photos below.

Testing we performed:
The BioTek 405 Select TS Microplate Washer passed all tests and was found to be fully functional:

Power on Initialize: PASSED
Touchscreen: PASSED
Priming Pump: PASSED
Dispense: PASSED
Aspirate: PASSED
Auto Clean method: PASSED
Shake: PASSED
Create/ Edit methods: PASSED
Biostack Power/Initialization: PASSED
Communication With BioStack: PASSED
Ran Wash Dispense Method Feeding From/To BioStack: PASSED

All functions have been tested and found to be operating within specification.
The 96/384 well head has been checked and cleaned thoroughly to ensure maximum efficiency during operation.

System consists of:
BioTek 405 Select TS Microplate Washer 405TSUVS
BioStack Automated Stacker
**New** Vacuum Pump
Waste Bottle
Buffer Bottle
Communication and power cables, and hoses

Washer is shown configured with the Biotek/Agilent LHC 2.0 application that allows for easier instrument and stacker configuration.
Please note computer with LHC 2.0 is not included. You will need to purchase your own license directly from Agilent for around $2,200.00

LHC application is not required to operate both stacker and instrument.
Full method configuration can be done from the touch menu on the 405TS.(This is how majority of users use it).


Configuration and Setup:
Manifold type: 96-/384-well washing: Dual-Action 96-tube (8x12)
Microplate Types: 96, 384; Plate Profile: standard
Volume range: 50 – 3,000 uL/well
Shaking: YES, Soaking: YES, Sonicating: YES
Number Dispensing Liquids: 4
Wash speed: 96-well, 3 cycles, 300 uL/well: <30 seconds; 384-well, 3 cycles, 100 uL/well: <80 seconds
Options: Dual Manifold, Buffer Switching, Ultrasonic Advantage, Programmable Shaking
Dimensions (D x W x H): 17 x 14 x 10 in (43.2 x 35.6 x 25.4 cm)
Weight: 30 lbs (13.5 kg)
Power: 100 - 240 VAC. 50/60 Hz

Video Description:
The video below gives an overview of the BioTek 405 Select TS Microplate Washer, and also demonstrates its functionality and functionality with LHC software.

Documentation:
Datasheet: BioTek 405 Select TS Microplate Washer

Brochure: BioTek 405 Select TS Microplate Washer

Manual: BioTek 405 Select TS Microplate Washer

(2) Parcel
25" x 25" x 25" @ 40#
21" x 17" x 15" @ 30#

Please do not hesitate to contact us if you have any questions.

All equipment warranty request must have a support case opened within the 60-day warranty period.
To open a support case, please send an email to [email protected] or call (508)974-4896.
Please provide your name, contact information, quotation/invoice number and a brief description of the issue that you are experiencing.
Phone and/or Email support will be provided prior to scheduling a return.
Please see the link below for our detailed warranty statement.
Customers must retain all original shipping materials during the warranty period.

Every instrument has unique packing and shipping needs. Few instruments can be safely shipped via Pacel, and most require the safety of a well-built crate.

Here we are showing you our standard packing process  

      1. All items are different, but they all follow the same principle when packaging.

      2. Start with a well-constructed crate

A well-constructed crate would consist of 1/2” to 5/8” Plywood with framing. We generally purchase our crates from a third party who specializes in custom crates.

      3. You always want the Instrument to not be directly on the wood deck of the crate. This is done by placing it on foam, inside of the crate. We use 2” 1.7 lb. density foam which works great. It provides cushioning and enough firmness to support the Instrument.

      4. The next step is to make sure there is nothing on the deck of the Instrument and the Head/ Arm is secured. In some cases there will be multiple arms to secure but for this example there is only one. The reason for this is so there is no free movement during transit which could cause serious damage to the Instrument.

      5. The next step is to make sure your Instrument is covered in either a pallet bag or shrink wrap so no dust or foreign object will get into the crate.

      6. The next step is to secure the instrument inside the crate by bracing. We use a method of 2x4’s which have 1” foam shrink wrapped to them so no piece of wood touches the actual instrument.

      7. Final step is to photograph everything inside the crate and then seal it with screws.

 

Safe Shipping
From Small Packages to Large Freight
International Shipping
Happy customers all around the world
Warranty
60-days
Registered Vendor To