Here is an Agilent ACEA xCELLigence W380 RTCA Real-Time Cell Analyzer

ACEA Biosciences now is a part of Agilent Technologies.
ACEA also has exclusive agreement with Roche for the development and distribution (that's how Roche logo appeared on the item)

Predecessor to:
Current model.

Condition:
This Agilent ACEA xCELLigence W380 RTCA Real-Time Cell Analyzer is in good working order.

Please see the exact video and photos below.

Testing we performed:
The Agilent ACEA xCELLigence W380 RTCA Real-Time Cell Analyzer passed all tests and was found to be fully functional:
Tested communication with software: PASSED
Tested initialization and self-test: PASSED
Scanned resistor plate test: PASSED

This Agilent ACEA xCELLigence W380 RTCA Real-Time Cell Analyzer was tested using xCELLigence SP Single-Plate 96-well and software from another
system and was found to be working as designed. This testing confirms that you can purchase with confidence knowing this component will work once added to your system.

System consists of:
ACEA xCELLigence W380 RTCA Real-Time Cell Analyzer
Power cable

Please note: the listing is for ACEA xCELLigence W380 RTCA only, - no laptop, SP Single-Plate or resistor plate included: they were used for testing purposes only.

Configuration and Setup:
Output Test Signal: 22mV rms +/- 20% @ 10, 25 and 50 kHz
Impedance Measurement Accuracy / Repeatability: +/- (1% + 1.5 ohm) / 0.8%
Impedance Dynamic Range: 10 Om to 5 kOm
Measurement Rate: < 10 seconds (per measurement for one E-Plate 96)
Dimensions RTCA (WxDxH): 40 x 40 x 8cm

Video Description:
In this video we show the Agilent ACEA xCELLigence W380 RTCA Real-Time Cell Analyzer and then proceed to walk around and show all the connections and serial number.
We then show the SP station and the resistor plate. We then put the resistor plate through a test. Everything works properly and results are shown.

Please note: the laptop and SP station are not included - they were used to show good working order of the ACEA xCELLigence W380 RTCA Real-Time Cell Analyzer.

Documentation:
Datasheet: https://drive.google.com/file/d/1nbVVYVb304baWbvB22ojS7Y_vYXIOKz3/view?usp=sharing

Brochure: https://drive.google.com/file/d/1RXBGuP-icJIYu5bubj36IlmuFa1D2uAe/view?usp=sharing

Manual: https://drive.google.com/file/d/1Bp8G_HJmiKL4FamcIZ3EgE1E4lpPHDHu/view?usp=sharing

Please do not hesitate to contact us if you have any questions.

 
 photo 15088- 9.JPG  photo 15088- 10.JPG  photo 15088- 3.JPG  photo 15088- 4.JPG  photo 15088- 5.JPG  photo 15088- 6.JPG  photo 15088- 7.JPG  photo 15088- 8.JPG

Safe Shipping
From Small Packages to Large Freight
International Shipping
Happy customers all around the world
Warranty
60-days
Registered Vendor To
Many US Colleges, Universities and Fortune 500 Companies