Menu
Your Cart

Thermo Luminex FlexMAP 3D Multiplexing Flow Cytometry Microplate Reader - AV

Thermo Luminex FlexMAP 3D Multiplexing Flow Cytometry Microplate Reader - AV
Thermo Luminex FlexMAP 3D Multiplexing Flow Cytometry Microplate Reader - AV
  • Stock: In Stock
  • Brand: Luminex
  • Product Code: 31801
  • Availability:1
$17,995.00

Here is a Thermo Luminex FlexMAP 3D Multiplexing Flow Cytometry Microplate Reader

Now branded by Thermo Scientific (P/N APX1342)

New sells for around $100K

Predecessor to:
Current model

Condition:
This Luminex FlexMAP 3D Bio-Rad Bio-Plex Multiplexing Flow Cytometry Microplate Reader is in good working order.

Please see the exact video and photos below.

Testing we performed:
The Luminex FlexMAP 3D Bio-Rad Bio-Plex Multiplexing Flow Cytometry Microplate Reader passed all tests and was found to be fully functional:
Tested connection to software: PASSED
Tested routine creation: PASSED
Tested report function: PASSED
Tested calibration procedure: PASSED
Tested performance verification procedure: PASSED
Tested fluidics function: PASSED
Tested laser warm up: PASSED
Tested sheath pressure: PASSED

System consists of:
Luminex FlexMAP 3D Multiplexing Microplate Reader
Desktop PC running Xponent ver4.2 software (w/ monitor, keyboard, mouse)
Source bottle
Waste bottle
Communication and power cables, and hoses.

Configuration and Setup:
Laser Type: Reporter Laser 532 nm and Classification Laser 638 nm
Detectors: Photomultiplier tube, detection bandwidth of 565 to 585 nm along with Avalanche photo diodes with temperature compensation
Microspheres: Distinguishes 1 to 500 unique xMAP microspheres in a single sample
Sample Handling: 96- or 384-well microtiter plate
Read time : ~20 min/96-well plate ~75 min/384-well plate
Sample Volume: 20-200ul

Fast read time, compatibility with both 96- and 384-well plates, and ease of integration with front-end automation systems make the Luminex FlexMAP 3D Bio-Rad Bio-Plex Multiplexing Flow Cytometry Microplate Reader the platform of choice for high throughput applications.
The platform uses both magnetic and non-magnetic microspheres and is capable of simultaneously measuring up to 500 genes or proteins from a small sample.
Automated start-up, shut-down, and maintenance routines make the Luminex FlexMAP 3D Bio-Rad Bio-Plex Multiplexing Flow Cytometry Microplate Reader easy to use and maintain.

Video Description:
The video gives an overview of the Luminex FlexMAP 3D Bio-Rad Bio-Plex Multiplexing Flow Cytometry Microplate Reader, and also performs functionality.

Documentation:
Datasheet: https://drive.google.com/file/d/18Bdj-NlHsT-itN_tTr0bD0t3G34-Zc1u/view?usp=sharing

Brochure: N/A

Manual: https://drive.google.com/file/d/18T9MtmmvrjQjfj00raWDb35JaQVLJ2X9/view?usp=sharing

Verification Test: https://drive.google.com/file/d/1p_WJsx2csv6pxE6QESE2V5s-yU6gEHRB/view?usp=sharing

This will ship via freight. Please contact us with your zip code to obtain shipping quote.

*ME* Medium Crate
400#

Please do not hesitate to contact us if you have any questions.

 photo 11986- 23.jpg

Here we are showing you our standard packing process  

      1. All items are different, but they all follow the same principle when packaging.

      2. Start with a well-constructed crate

A well-constructed crate would consist of 1/2” to 5/8” Plywood with framing. We generally purchase our crates from a third party who specializes in custom crates.

      3. You always want the Instrument to not be directly on the wood deck of the crate. This is done by placing it on foam, inside of the crate. We use 2” 1.7 lb. density foam which works great. It provides cushioning and enough firmness to support the Instrument.

      4. The next step is to make sure there is nothing on the deck of the Instrument and the Head/ Arm is secured. In some cases there will be multiple arms to secure but for this example there is only one. The reason for this is so there is no free movement during transit which could cause serious damage to the Instrument.

      5. The next step is to make sure your Instrument is covered in either a pallet bag or shrink wrap so no dust or foreign object will get into the crate.

      6. The next step is to secure the instrument inside the crate by bracing. We use a method of 2x4’s which have 1” foam shrink wrapped to them so no piece of wood touches the actual instrument.

      7. Final step is to photograph everything inside the crate and then seal it with screws.

 

All equipment warranty request must have a support case opened within the 60-day Domestic USA and 30-day International warranty period.
To open a support case, please send an email to [email protected] or call (508)974-4896.
Please provide your name, contact information, quotation/invoice number and a brief description of the issue that you are experiencing.
Phone and/or Email support will be provided prior to scheduling a return.
Please see the link below for our detailed warranty statement.
Customers must retain all original shipping materials during the warranty period.

Safe Shipping
From Small Packages to Large Freight
International Shipping
Happy customers all around the world
Warranty
60-day Domestic USA and
30-day International
Registered Vendor To
Many US Colleges, Universities and Fortune 500 Companies