Categories

PCR Preparation Systems

Display: List /Grid
Show:
Sort By:
Fluidigm C1 Single-Cell AutoPrep DNA/RNA Preparation
Fluidigm C1 Single-Cell AutoPrep DNA/RNA Preparation
Thermal Control: peltier-based, 4 - 99C
IFC Compatibility: 96-cell and HT C1 IFC
Sample Sources: primary and cultured cells; Sample Input: 200 - 1,000 cells (96-cell IFC), 2,000 - 5,000 cells (HT IFC)
Cell Capture Efficiency: small-cell (5 - 10um) >=80% of capture sites will contain cells with 1,000 HL-60 cells input; medium
Power Requirements: 120V AC, 50/60Hz, 8A
Dimensions(WxDxH): 41 x 66 x 48cm (16 x 26 x 19in), Weight 45kg (99lb)
$14,995.00

Qiagen QIAgility PCR Real-Time Unit2
Qiagen QIAgility PCR Real-Time Unit2
Temperature Range: 15-30C (59-86F)
Humidity: 40-70%
Tip Volume: 1-200ul
Precision: CV - 1%, 5-200ul (dry-well transfer) CV <5%, 2-5ul (wet-well transfer) CV - 10%, 1ul
Liquid-Level Sensing: minimum detection volume (10ul in 200ul PCR tubes) - only functional in combination with QIAGEN Conductive
$7,495.00

Qiagen QIAgility PCR Real-Time Automated PCR Preparation
Qiagen QIAgility PCR Real-Time Automated PCR Preparation
Temperature Range: 15-30C (59-86F)
Humidity: 40-70%
Tip Volume: 1-200ul
Precision: CV - 1%, 5-200ul (dry-well transfer) CV <5%, 2-5ul (wet-well transfer) CV - 10%, 1ul
Liquid-Level Sensing: minimum detection volume (10ul in 200ul PCR tubes) - only functional in combination with QIAGEN Conductive
$6,995.00

Fluidigm AX Controller BioMark IFC PCR Unit2
Fluidigm AX Controller BioMark IFC PCR Unit2
Chip supported: 151
Experiment tracking: Barcode
Gas pressure: Internal compressor
Interface: USB and Ethernet
$1,495.00

AB Applied Biosystems / Life Technologies Quantstudio 12K Flex Accufill System SOLDOUTAB Applied Biosystems / Life Technologies Quantstudio 12K Flex Accufill System SOLDOUT

Bioneer Exiprep 16 Nucleic Acid Extraction System Pred, Plus SOLDOUTBioneer Exiprep 16 Nucleic Acid Extraction System Pred, Plus SOLDOUT
Bioneer Exiprep 16 Nucleic Acid Extraction System Pred, Plus SOLDOUT
Touch Screen
High quality DNA/RNA at an affordable price
UV sterilization cycle after each run: Eliminates the possibility of inter-assay cross-contamination
Walk-away automation: Maximizes your efficiency in the lab

Bioneer Exiprep 16 Nucleic Acid Extraction System SOLDOUTBioneer Exiprep 16 Nucleic Acid Extraction System SOLDOUT
Bioneer Exiprep 16 Nucleic Acid Extraction System SOLDOUT
Touch Screen
High quality DNA/RNA at an affordable price
UV sterilization cycle after each run: Eliminates the possibility of inter-assay cross-contamination
Walk-away automation: Maximizes your efficiency in the lab

New Thermo ABI OpenArray AccuFill PCR Instrument SOLDOUTNew Thermo ABI OpenArray AccuFill PCR Instrument SOLDOUT
New Thermo ABI OpenArray AccuFill PCR Instrument SOLDOUT
Robotic dispensing arm with X, Y and Z axes
48-channel disposable pipette head
Allows for 2 separate tip boxes and a sample tray
Application: increase throughput for a QuantStudio 12K Flex Real-Time PCR System by automating sample loading

Perkin Elmer chemagic MSM I Nucleic Acid DNA/RNA Isolation Workstation SOLDOUTPerkin Elmer chemagic MSM I Nucleic Acid DNA/RNA Isolation Workstation SOLDOUT
Perkin Elmer chemagic MSM I Nucleic Acid DNA/RNA Isolation Workstation SOLDOUT
Head type: 24 and 96
Volume per Channel: 24 channel 200 ul - 4 ml, 96 channel 10 ul - 400 ul
Rotating electromagnetic rod heads
Application: High throughput nucleic acid isolation

Qiagen EZ1 Advanced XL Extraction Robot SOLDOUTQiagen EZ1 Advanced XL Extraction Robot SOLDOUT

Qiagen QIAcube Automated DNA/RNA Purification System SOLDOUTQiagen QIAcube Automated DNA/RNA Purification System SOLDOUT
Qiagen QIAcube Automated DNA/RNA Purification System SOLDOUT
Centrifuge: 10,640 RPM, Swinging bucket rotor (max 45deg), 12 rotor positions (max load 12x15g)
Shaker: Speed 100–2000 RPM, Amplitude 2 mm, Heating range of ambient temperature to 70C (158F), Ramp-up time of <5 minutes fr
Pipetting system: Syringe size 1 ml, Pipetting range 5–900ul, up to 12 samples per run
Power: 120/240 VAC, 50-60 Hz, 650 VA
Protocols/main application on this instrument: DNA purification, RNA purification, protein purification

Qiagen QIAcube Automated DNA/RNA Purification System SOLDOUTQiagen QIAcube Automated DNA/RNA Purification System SOLDOUT
Qiagen QIAcube Automated DNA/RNA Purification System SOLDOUT
Centrifuge: 10,640RPM, swinging bucket rotor (max 45deg), 12 rotor positions (max load 12x15g)
Shaker: speed 100–2000 RPM, amplitude 2 mm, heating range of ambient temperature to 70C (158F), ramp-up time of <5 minutes
Pipetting System: syringe size 1 ml, pipetting range 5–900ul, up to 12 samples per run
Protocols / Main Application: DNA purification, RNA purification, protein purification
Power: 120/240VAC, 50-60Hz, 650VA

Qiagen QIAcube Automated DNA/RNA Purification System SOLDOUTQiagen QIAcube Automated DNA/RNA Purification System SOLDOUT
Qiagen QIAcube Automated DNA/RNA Purification System SOLDOUT
Centrifuge: swing-out rotor, maximum 45dergrees, 12 rotor positions, max. 12,000 RPM
Shaker: 100 - 2000 RPM, amplitude 2 mm, heating range of ambient temperature to 70C (158F), ramp-up time of <5 minutes from a
Pipetting system: syringe size 1 ml, pipetting range 5 - 900 ul, up to 12 samples per run.
Power: 100-120 V AC, 50-60 Hz, 650 VA (North America and Japan), 220-240 V AC, 50-60 Hz, 650 VA (Europe)
Protocols/main application on this instrument: DNA purification, RNA purification, Protein purification

Qiagen QIAcube Automated DNA/RNA Purification System Unit2 SOLDOUTQiagen QIAcube Automated DNA/RNA Purification System Unit2 SOLDOUT
Qiagen QIAcube Automated DNA/RNA Purification System Unit2 SOLDOUT
Centrifuge: 10,640 RPM, Swinging bucket rotor (max 45deg), 12 rotor positions (max load 12x15g)
Shaker: Speed 100–2000 RPM, Amplitude 2 mm, Heating range of ambient temperature to 70C (158F), Ramp-up time of <5 minutes fr
Pipetting system: Syringe size 1 ml, Pipetting range 5–900ul, up to 12 samples per run
Power: 120/240 VAC, 50-60 Hz, 650 VA
Protocols/main application on this instrument: DNA purification, RNA purification, protein purification

Qiagen QIAcube Automated DNA/RNA Purification System Unit2 SOLDOUTQiagen QIAcube Automated DNA/RNA Purification System Unit2 SOLDOUT
Qiagen QIAcube Automated DNA/RNA Purification System Unit2 SOLDOUT
Centrifuge: 10,640RPM, swinging bucket rotor (max 45deg), 12 rotor positions (max load 12x15g)
Shaker: speed 100–2000 RPM, amplitude 2 mm, heating range of ambient temperature to 70C (158F), ramp-up time of <5 minutes
Pipetting System: syringe size 1 ml, pipetting range 5–900ul, up to 12 samples per run
Protocols / Main Application: DNA purification, RNA purification, protein purification
Power: 120/240VAC, 50-60Hz, 650VA

Qiagen QIAcube Automated DNA/RNA Purification System Unit3 SOLDOUTQiagen QIAcube Automated DNA/RNA Purification System Unit3 SOLDOUT
Qiagen QIAcube Automated DNA/RNA Purification System Unit3 SOLDOUT
Centrifuge: 10,640 RPM, Swinging bucket rotor (max 45deg), 12 rotor positions (max load 12x15g)
Shaker: Speed 100–2000 RPM, Amplitude 2 mm, Heating range of ambient temperature to 70C (158F), Ramp-up time of <5 minutes fr
Pipetting system: Syringe size 1 ml, Pipetting range 5–900ul, up to 12 samples per run
Power: 120/240 VAC, 50-60 Hz, 650 VA
Protocols/main application on this instrument: DNA purification, RNA purification, protein purification

Qiagen QIAcube Automated DNA/RNA Purification System Unit3 SOLDOUTQiagen QIAcube Automated DNA/RNA Purification System Unit3 SOLDOUT
Qiagen QIAcube Automated DNA/RNA Purification System Unit3 SOLDOUT
Centrifuge: 10,640RPM, swinging bucket rotor (max 45deg), 12 rotor positions (max load 12x15g)
Shaker: speed 100–2000 RPM, amplitude 2 mm, heating range of ambient temperature to 70C (158F), ramp-up time of <5 minutes
Pipetting System: syringe size 1 ml, pipetting range 5–900ul, up to 12 samples per run
Protocols / Main Application: DNA purification, RNA purification, protein purification
Power: 120/240VAC, 50-60 Hz, 650VA

Qiagen QiaCube Automated Purification System SOLDOUTQiagen QiaCube Automated Purification System SOLDOUT
Qiagen QiaCube Automated Purification System SOLDOUT
Up to 12 samples per run
Built in pipetting system
Heated shaker
Automated lyse, bind, wash, and elute.
Uses QIAGEN spin-column kits for ease of use

Qiagen QIAcube cube DNA/RNA Purification System SOLDOUTQiagen QIAcube cube DNA/RNA Purification System SOLDOUT
Qiagen QIAcube cube DNA/RNA Purification System SOLDOUT
Centrifuge: swing-out rotor (maximum 45dergrees), 12 rotor positions (15 grams each), max. 10,640 RPM
Shaker: 100–2000 RPM, amplitude 2 mm, heating range of ambient temperature to 70C (158F), ramp-up time of <5 minutes from amb
Pipetting system: syringe size 1 ml, pipetting range 5–900 ul, up to 12 samples per run
Power: 110-120VAC
Protocols / main application on this instrument: DNA purification, RNA purification, protein purification

Qiagen QIAcube DNA/RNA Purification Sample Preparation SOLDOUTQiagen QIAcube DNA/RNA Purification Sample Preparation SOLDOUT
Qiagen QIAcube DNA/RNA Purification Sample Preparation SOLDOUT
Centrifuge: 10,640 RPM, Max load 12x15 g
Shaker: Speed 100–2000 RPM, Amplitude 2 mm, Heating range of ambient temperature to 70C (158F), Ramp-up time of <5 minutes fr
Pipetting system: Syringe size 1 ml, Pipetting range 5–900 ul, Capacity: Up to 12 samples per run
Power: 100-120 / 220-240 VAC, 50-60 Hz, 650 VA
Protocols / main application on this instrument: DNA purification, RNA purification, protein purification

Qiagen QIAcube DNA/RNA Purification Unit#2 SOLDOUTQiagen QIAcube DNA/RNA Purification Unit#2 SOLDOUT
Qiagen QIAcube DNA/RNA Purification Unit#2 SOLDOUT
Centrifuge: swing-out rotor (maximum 45dergrees), 12 rotor positions (15 grams each), max. 10,640 RPM
Shaker: 100–-2000 RPM, amplitude 2 mm, heating range of ambient temperature to 70C (158F), ramp-up time of <5 minutes from am
Pipetting system: syringe size 1 ml, pipetting range 5–900 ul, up to 12 samples per run
Power: 110-120VAC
Protocols / main application on this instrument: DNA purification, RNA purification, protein purification

Qiagen QIAcube DNA/RNA Purification Workstation Unit Number #3 SOLDOUTQiagen QIAcube DNA/RNA Purification Workstation Unit Number #3 SOLDOUT
Qiagen QIAcube DNA/RNA Purification Workstation Unit Number #3 SOLDOUT
Centrifuge: swing-out rotor (maximum 45dergrees), 12 rotor positions (15 grams each), max. 10,640 RPM
Shaker: 100-2000 RPM, amplitude 2 mm, heating range of ambient temperature to 70C (158F), ramp-up time of <5 minutes from amb
Pipetting system: syringe size 1 ml, pipetting range 5?900 ul, up to 12 samples per run
Power: 110-120VAC
Protocols / main application on this instrument: DNA purification, RNA purification, protein purification

Qiagen QIAgility Automated PCR unit 3 SOLDOUTQiagen QIAgility Automated PCR unit 3 SOLDOUT
Qiagen QIAgility Automated PCR unit 3 SOLDOUT
Temperature Range: 15 - 30C (59 - 86F)
Humidity: 40 - 70%
Tip Volume: 1 - 200ul
Precision: CV 1%, 5 - 200ul (dry-well transfer) CV 5%, 2 - 5ul (wet-well transfer) CV 10%, 1u
Liquid-Level Sensing: minimum detection volume (10ul in 200ul PCR tubes) - only functional in combination with QIAGEN Conductive

Qiagen QIAgility High-Precision Automated PCR System QI agility SOLDOUTQiagen QIAgility High-Precision Automated PCR System QI agility SOLDOUT

Qiagen QIAgility Multipurpose PCR unit 2 SOLDOUTQiagen QIAgility Multipurpose PCR unit 2 SOLDOUT
Qiagen QIAgility Multipurpose PCR unit 2 SOLDOUT
Temperature Range: 15–30C (59–86F)
Humidity: 40–70%
Tip Volume: 1–200ul
Precision: CV <1%, 5–200ul (dry-well transfer) CV <5%, 2–5ul (wet-well transfer) CV <10%, 1ul
Liquid-Level Sensing: minimum detection volume (10ul in 200ul PCR tubes) - only functional in combination with QIAGEN Conductive


Boston Industries, Inc. © 2020