Categories

PCR Preparation Systems

Display: List /Grid
Show:
Sort By:
Fluidigm C1 Single-Cell AutoPrep DNA/RNA Preparation
Fluidigm C1 Single-Cell AutoPrep DNA/RNA Preparation
Thermal Control: peltier-based, 4 - 99C
IFC Compatibility: 96-cell and HT C1 IFC
Sample Sources: primary and cultured cells; Sample Input: 200 - 1,000 cells (96-cell IFC), 2,000 - 5,000 cells (HT IFC)
Cell Capture Efficiency: small-cell (5 - 10um) >=80% of capture sites will contain cells with 1,000 HL-60 cells input; medium
Power Requirements: 120V AC, 50/60Hz, 8A
Dimensions(WxDxH): 41 x 66 x 48cm (16 x 26 x 19in), Weight 45kg (99lb)
$14,995.00

Qiagen QIAgility PCR Real-Time Unit2
Qiagen QIAgility PCR Real-Time Unit2
Temperature Range: 15-30C (59-86F)
Humidity: 40-70%
Tip Volume: 1-200ul
Precision: CV - 1%, 5-200ul (dry-well transfer) CV <5%, 2-5ul (wet-well transfer) CV - 10%, 1ul
Liquid-Level Sensing: minimum detection volume (10ul in 200ul PCR tubes) - only functional in combination with QIAGEN Conductive
$5,995.95

Qiagen QIAgility PCR Real-Time Automated PCR Preparation
Qiagen QIAgility PCR Real-Time Automated PCR Preparation
Temperature Range: 15-30C (59-86F)
Humidity: 40-70%
Tip Volume: 1-200ul
Precision: CV - 1%, 5-200ul (dry-well transfer) CV <5%, 2-5ul (wet-well transfer) CV - 10%, 1ul
Liquid-Level Sensing: minimum detection volume (10ul in 200ul PCR tubes) - only functional in combination with QIAGEN Conductive
$5,995.00

Fluidigm AX Controller BioMark IFC PCR Unit2
Fluidigm AX Controller BioMark IFC PCR Unit2
Chip supported: 151
Experiment tracking: Barcode
Gas pressure: Internal compressor
Interface: USB and Ethernet
$1,495.00

Roche MagNA Pure 96 DNA/RNA Purification SOLDOUTRoche MagNA Pure 96 DNA/RNA Purification SOLDOUT
Roche MagNA Pure 96 DNA/RNA Purification SOLDOUT
Number of Samples: 1 to 96 reactions per run
Sample Input Volume: 50uL to 1mL, up to 4mL for plasma sample
Elution Volume: 50 to 200uL
Setup Time: 5 mins approx
Run Time: 50 to 90 mins approx depending on protocol

Qiagen Rotor-Gene Q PCR Cycler 5 Plex, QIAgility Prep System, Rotor-Disc Sealer SOLDOUTQiagen Rotor-Gene Q PCR Cycler 5 Plex, QIAgility Prep System, Rotor-Disc Sealer SOLDOUT
Qiagen Rotor-Gene Q PCR Cycler 5 Plex, QIAgility Prep System, Rotor-Disc Sealer SOLDOUT
Samples per Run: tubes 0.2 ml
strip tubes 0.1 ml (4 tubes)
rotor-disc 72
rotor-disc 100
up to 100 samples per run using a rotor-disc 100

Qiagen QIAxtractor High Throughput Nucleic Acid Purification alt to QiaCube HT SOLDOUTQiagen QIAxtractor High Throughput Nucleic Acid Purification alt to QiaCube HT SOLDOUT
Qiagen QIAxtractor High Throughput Nucleic Acid Purification alt to QiaCube HT SOLDOUT
HEPA air filtration and UV Sterilization
96 samples can be processed in 96 Minutes
Reliable process ensures absence of cross-contamination.
8 Channel pipetting arm
Nucleic acid purification

Qiagen QIAsymphony SP/AS DNA Preparation System QIA Symphony SPAS SOLDOUTQiagen QIAsymphony SP/AS DNA Preparation System QIA Symphony SPAS SOLDOUT
Qiagen QIAsymphony SP/AS DNA Preparation System QIA Symphony SPAS SOLDOUT
Fully automated
Purify DNA, RNA, or proteins from up to 96 samples
Built-in flexibility for laboratory workflow integration
Sample volumes of up to 1000 µl

Qiagen QIAsymphony SP Sample Preparation DNA RNA Purification SOLDOUTQiagen QIAsymphony SP Sample Preparation DNA RNA Purification SOLDOUT
Qiagen QIAsymphony SP Sample Preparation DNA RNA Purification SOLDOUT
Sample input volume: Up to 1000ul
Sample throughput: 1 to 96 per run
Dimensions: 130 x 125 x 163 cm

Qiagen QIAsymphony SP Sample Preparation DNA RNA Purification QIA 9001297 SOLDOUTQiagen QIAsymphony SP Sample Preparation DNA RNA Purification QIA 9001297 SOLDOUT
Qiagen QIAsymphony SP Sample Preparation DNA RNA Purification QIA 9001297 SOLDOUT
Sample input volume: Up to 1000ul
Sample throughput: 1 to 96 per run
Dimensions: 128 x 103 x 73 cm

Qiagen QIAsymphony SP Sample Preparation DNA RNA Made 2014 SOLDOUTQiagen QIAsymphony SP Sample Preparation DNA RNA Made 2014 SOLDOUT
Qiagen QIAsymphony SP Sample Preparation DNA RNA Made 2014 SOLDOUT
Robotic Arms: 1 pipetting arm
Channels: 4
Volume: 1ul to 1000ul
Sample input volume: up to 1000ul
Sample throughput: 1 to 96 per run

Qiagen QIAsymphony SP DNA Preperation System QIA symphony SOLDOUTQiagen QIAsymphony SP DNA Preperation System QIA symphony SOLDOUT

Qiagen QIAgility PCR Unit4 SOLDOUTQiagen QIAgility PCR Unit4 SOLDOUT
Qiagen QIAgility PCR Unit4 SOLDOUT
Temperature Range: 15-30C (59-86F), Humidity: 40-70%
Tip Volume: 1-200ul
Precision: CV - 1%, 5-200ul (dry-well transfer) CV <5%, 2-5ul (wet-well transfer) CV - 10%, 1ul
Liquid-Level Sensing: minimum detection volume (10ul in 200ul PCR tubes) - only functional in combination with QIAGEN Conductive
Dimensions(WxDxH): 54 x 63 x 45cm (21 x 25 x 18in)

Qiagen QIAgility PCR System SOLDOUTQiagen QIAgility PCR System SOLDOUT
Qiagen QIAgility PCR System SOLDOUT
Temperature Range: 15–30C (59–86F)
Humidity: 40–70%
Tip Volume: 1–200 ul
Precision: CV <1%, 5–200 ul (dry-well transfer) CV <5%, 2–5 ul (wet-well transfer) CV <10%, 1 ul
Dimensions (HxWxD): 45 x 54 x 63 cm (18 x 21 x 25 in)

Qiagen QIAgility PCR SOLDOUTQiagen QIAgility PCR SOLDOUT
Qiagen QIAgility PCR SOLDOUT
Temperature Range: 15–30C (59–86F)
Humidity: 40–70%
Tip Volume: 1–200ul
Precision: CV <1%, 5–200ul (dry-well transfer) CV <5%, 2–5ul (wet-well transfer) CV <10%, 1ul
Liquid-Level Sensing: minimum detection volume (10ul in 200ul PCR tubes) - only functional in combination with QIAGEN Conductive

Qiagen QIAgility Multipurpose PCR unit 2 SOLDOUTQiagen QIAgility Multipurpose PCR unit 2 SOLDOUT
Qiagen QIAgility Multipurpose PCR unit 2 SOLDOUT
Temperature Range: 15–30C (59–86F)
Humidity: 40–70%
Tip Volume: 1–200ul
Precision: CV <1%, 5–200ul (dry-well transfer) CV <5%, 2–5ul (wet-well transfer) CV <10%, 1ul
Liquid-Level Sensing: minimum detection volume (10ul in 200ul PCR tubes) - only functional in combination with QIAGEN Conductive

Qiagen QIAgility High-Precision Automated PCR System QI agility SOLDOUTQiagen QIAgility High-Precision Automated PCR System QI agility SOLDOUT

Qiagen QIAgility Automated PCR unit 3 SOLDOUTQiagen QIAgility Automated PCR unit 3 SOLDOUT
Qiagen QIAgility Automated PCR unit 3 SOLDOUT
Temperature Range: 15 - 30C (59 - 86F)
Humidity: 40 - 70%
Tip Volume: 1 - 200ul
Precision: CV 1%, 5 - 200ul (dry-well transfer) CV 5%, 2 - 5ul (wet-well transfer) CV 10%, 1u
Liquid-Level Sensing: minimum detection volume (10ul in 200ul PCR tubes) - only functional in combination with QIAGEN Conductive

Qiagen QIAcube DNA/RNA Purification Workstation Unit Number #3 SOLDOUTQiagen QIAcube DNA/RNA Purification Workstation Unit Number #3 SOLDOUT
Qiagen QIAcube DNA/RNA Purification Workstation Unit Number #3 SOLDOUT
Centrifuge: swing-out rotor (maximum 45dergrees), 12 rotor positions (15 grams each), max. 10,640 RPM
Shaker: 100-2000 RPM, amplitude 2 mm, heating range of ambient temperature to 70C (158F), ramp-up time of <5 minutes from amb
Pipetting system: syringe size 1 ml, pipetting range 5?900 ul, up to 12 samples per run
Power: 110-120VAC
Protocols / main application on this instrument: DNA purification, RNA purification, protein purification

Qiagen QIAcube DNA/RNA Purification Unit#2 SOLDOUTQiagen QIAcube DNA/RNA Purification Unit#2 SOLDOUT
Qiagen QIAcube DNA/RNA Purification Unit#2 SOLDOUT
Centrifuge: swing-out rotor (maximum 45dergrees), 12 rotor positions (15 grams each), max. 10,640 RPM
Shaker: 100–-2000 RPM, amplitude 2 mm, heating range of ambient temperature to 70C (158F), ramp-up time of <5 minutes from am
Pipetting system: syringe size 1 ml, pipetting range 5–900 ul, up to 12 samples per run
Power: 110-120VAC
Protocols / main application on this instrument: DNA purification, RNA purification, protein purification

Qiagen QIAcube DNA/RNA Purification Sample Preparation SOLDOUTQiagen QIAcube DNA/RNA Purification Sample Preparation SOLDOUT
Qiagen QIAcube DNA/RNA Purification Sample Preparation SOLDOUT
Centrifuge: 10,640 RPM, Max load 12x15 g
Shaker: Speed 100–2000 RPM, Amplitude 2 mm, Heating range of ambient temperature to 70C (158F), Ramp-up time of <5 minutes fr
Pipetting system: Syringe size 1 ml, Pipetting range 5–900 ul, Capacity: Up to 12 samples per run
Power: 100-120 / 220-240 VAC, 50-60 Hz, 650 VA
Protocols / main application on this instrument: DNA purification, RNA purification, protein purification

Qiagen QIAcube cube DNA/RNA Purification System SOLDOUTQiagen QIAcube cube DNA/RNA Purification System SOLDOUT
Qiagen QIAcube cube DNA/RNA Purification System SOLDOUT
Centrifuge: swing-out rotor (maximum 45dergrees), 12 rotor positions (15 grams each), max. 10,640 RPM
Shaker: 100–2000 RPM, amplitude 2 mm, heating range of ambient temperature to 70C (158F), ramp-up time of <5 minutes from amb
Pipetting system: syringe size 1 ml, pipetting range 5–900 ul, up to 12 samples per run
Power: 110-120VAC
Protocols / main application on this instrument: DNA purification, RNA purification, protein purification

Qiagen QiaCube Automated Purification System SOLDOUTQiagen QiaCube Automated Purification System SOLDOUT
Qiagen QiaCube Automated Purification System SOLDOUT
Up to 12 samples per run
Built in pipetting system
Heated shaker
Automated lyse, bind, wash, and elute.
Uses QIAGEN spin-column kits for ease of use

Qiagen QIAcube Automated DNA/RNA Purification System Unit3 SOLDOUTQiagen QIAcube Automated DNA/RNA Purification System Unit3 SOLDOUT
Qiagen QIAcube Automated DNA/RNA Purification System Unit3 SOLDOUT
Centrifuge: 10,640 RPM, Swinging bucket rotor (max 45deg), 12 rotor positions (max load 12x15g)
Shaker: Speed 100–2000 RPM, Amplitude 2 mm, Heating range of ambient temperature to 70C (158F), Ramp-up time of <5 minutes fr
Pipetting system: Syringe size 1 ml, Pipetting range 5–900ul, up to 12 samples per run
Power: 120/240 VAC, 50-60 Hz, 650 VA
Protocols/main application on this instrument: DNA purification, RNA purification, protein purification

Qiagen QIAcube Automated DNA/RNA Purification System Unit3 SOLDOUTQiagen QIAcube Automated DNA/RNA Purification System Unit3 SOLDOUT
Qiagen QIAcube Automated DNA/RNA Purification System Unit3 SOLDOUT
Centrifuge: 10,640RPM, swinging bucket rotor (max 45deg), 12 rotor positions (max load 12x15g)
Shaker: speed 100–2000 RPM, amplitude 2 mm, heating range of ambient temperature to 70C (158F), ramp-up time of <5 minutes
Pipetting System: syringe size 1 ml, pipetting range 5–900ul, up to 12 samples per run
Protocols / Main Application: DNA purification, RNA purification, protein purification
Power: 120/240VAC, 50-60 Hz, 650VA


Boston Industries, Inc. © 2020