ALS Jena Aviso CellCelector Cell Picking System w/ Olympus CKX41 Microscope
ALS Jena Aviso CellCelector Cell Picking System w/ Olympus CKX41 Microscope
Microscope: Inverted setup with Standard and Fluorescent lighting, 10X objective, and CCD camera
Operation parameters: 1 to 384 well plates as well as non standard labware with 50um capillary cell selection size
Robotic Components: Cell selecting arm with capillary tool, microscope control including focus and XY stage movement
Software: Cell^D 2.8 image recognition software for automatically identifying, counting, and documenting cells and particles
Application: Single cell harvesting and cell colony counting
$24,995.00

Bio-Rad Bio-Plex 200 Luminex Suspension Array Analyzer with Bio-plex Manager
Bio-Rad Bio-Plex 200 Luminex Suspension Array Analyzer with Bio-plex Manager
Number of lasers: 2 Lasers
Laser type: Reporter Laser 532 nm and Classification Laser 635 nm
System checks for type of bead and if bead has analytes attached to it
Sample handling: System uses 96 well-plates
Sample Volume: 20-200uL
$11,995.00

Bio-Rad Luminex Bio-Plex 200 Suspension Array Analyzer
Bio-Rad Luminex Bio-Plex 200 Suspension Array Analyzer
Laser type: Reporter Laser 532 nm and Classification Laser 635 nm
Number of lasers: 2 Lasers
System checks for type of bead and if bead has analytes attached to it
Sample handling: System uses 96 well-plates
$7,995.00

Bio-Rad Luminex Bio-Plex 200 Suspension Array Analyzer w/ BioPlex Manager 6.1
Bio-Rad Luminex Bio-Plex 200 Suspension Array Analyzer w/ BioPlex Manager 6.1
Laser type: Reporter Laser 532 nm and Classification Laser 635 nm
Number of lasers: 2 Lasers
System checks for type of bead and if bead has analytes attached to it
Sample handling: System uses 96 well-plates
Sample Volume 20-200uL
$11,995.00

CellTracks AutoPrep Cell Track w/ Fluorescence Analyzer
CellTracks AutoPrep Cell Track w/ Fluorescence Analyzer
Test type: Circulating Tumor Cell
Separation Method: Magnetic-activated cell sorting
Detection: Fluorescence of stained cells using Analyzer II
$1,795.00

CellTracks Fluorescence Analyzer II
CellTracks Fluorescence Analyzer II
Time to process each cartridge: 10 minutes
Detection: Fluorescence of stained cells
Test type: Circulating Tumor Cell
Power: 100-240V 50-60Hz
Separation Method: Magnetic-activated cell sorting
$895.00

BD Biosciences FACSCalibur Flow Cytometer 342975 PM ON 11/15/16 SOLDOUTBD Biosciences FACSCalibur Flow Cytometer 342975 PM ON 11/15/16 SOLDOUT
BD Biosciences FACSCalibur Flow Cytometer 342975 PM ON 11/15/16 SOLDOUT
Excitation lasers: Blue 488 nm and Red 635 nm
Sample types: Cells and multiplex bead assays
Optics: FSC, SSC, FL1(530/30nm), FL2(585/42nm), FL3(670nm LP) and FL4(661/16nm)
Sample Handling: 12x75mm test tubes
Applications: Cell counting, aiding DNA analysis, Bead Array assays and Immunophenotyping

BD FACSCalibur Flow Cytometer Cell Analyzer with Cell Sorting SOLDOUTBD FACSCalibur Flow Cytometer Cell Analyzer with Cell Sorting SOLDOUT
BD FACSCalibur Flow Cytometer Cell Analyzer with Cell Sorting SOLDOUT
Excitation lasers: Blue 488 nm and Red 635 nm
Sample types: Cells and multiplex bead assays
Optics: FSC, SSC, FL1(530/30nm), FL2(585/42nm), FL3(670nm LP) and FL4(661/16nm)
Sample Handling: Facsloader: (40) 12x75mm test tubes per with 4 racks
Applications: Cell counting, aiding DNA analysis, Bead Arry assays and Immunophenotyping

BD FACSVerse Flow Cytometer 6 Color 2 Laser P/N 651154 with FACSLoader SOLDOUTBD FACSVerse Flow Cytometer 6 Color 2 Laser P/N 651154 with FACSLoader SOLDOUT
BD FACSVerse Flow Cytometer 6 Color 2 Laser P/N 651154 with FACSLoader SOLDOUT
Excitation lasers: Blue 488nm and Red 640nm
Sample types: Cells, Micro beads and other stained particles
Sample Handling: Single tubes, 96- and 384-well microplates, 30-tube rack and 40-tube rack (40-tube rack included)
Sheath Fluid: BD FacsFlow Sheath fluid
Sample Volume: 55-2000 uL

Beckman Coulter Z1 D Particle Counter Dual Threshold 6605699 SOLDOUTBeckman Coulter Z1 D Particle Counter Dual Threshold 6605699 SOLDOUT
Beckman Coulter Z1 D Particle Counter Dual Threshold 6605699 SOLDOUT
Type: Coulter Counter
Detector Used: Electrical Zone Method (EMZ)
Measuring Time: N/A
Light Source: 50W 12V GU5.3 Halogen bulb
Particle Size Range: 1-120 Microns

Becton Dickinson BD FACSCalibur Flow Cytometer 4 Color - PM done on 11/15/2016 SOLDOUTBecton Dickinson BD FACSCalibur Flow Cytometer 4 Color - PM done on 11/15/2016 SOLDOUT
Becton Dickinson BD FACSCalibur Flow Cytometer 4 Color - PM done on 11/15/2016 SOLDOUT
Excitation lasers: Blue 488 nm and Red 635 nm
Sample types: Cells and multiplex bead assays
Optics: FSC, SSC, FL1(530/30nm), FL2(585/42nm), FL3(670nm LP) and FL4(661/16nm)
Sample Handling: 96 wellplates (via cytek auto sampler) and single BD 12x75mm sample tubes
Applications: Cell counting, aiding DNA analysis, Bead Arry assays and Immunophenotyping

Becton Dickinson BD FACSCalibur Flow Cytometer SOLDOUTBecton Dickinson BD FACSCalibur Flow Cytometer SOLDOUT
Becton Dickinson BD FACSCalibur Flow Cytometer SOLDOUT
Excitation lasers: Blue 488 nm and Red 635 nm
Sample types: Cells and multiplex bead assays
Optics: FSC, SSC, FL1(530/30nm), FL2(585/42nm), FL3(670nm LP) and FL4(661/16nm)
Sample Handling: 12x75mm test tubes

Bio-Rad (Luminex) Bio-Plex 200 Suspension Array Analyzer w/ Bio-Plex Manager 6.1 SOLDOUTBio-Rad (Luminex) Bio-Plex 200 Suspension Array Analyzer w/ Bio-Plex Manager 6.1 SOLDOUT
Bio-Rad (Luminex) Bio-Plex 200 Suspension Array Analyzer w/ Bio-Plex Manager 6.1 SOLDOUT
Number of lasers: 2 Lasers
Laser type: Reporter Laser 532 nm and Classification Laser 635 nm
System checks for type of bead and if bead has analytes attached to it
Sample handling: System uses 96 well-plates
Sample Volume: 20-200uL

Bio-Rad Bio-Plex 200 Multiplexing Analyzer System. It is a rebranded Luminex 200 SOLDOUTBio-Rad Bio-Plex 200 Multiplexing Analyzer System. It is a rebranded Luminex 200 SOLDOUT
Bio-Rad Bio-Plex 200 Multiplexing Analyzer System. It is a rebranded Luminex 200 SOLDOUT
Laser type: Reporter Laser 532 nm and Classification Laser 635 nm
Number of lasers - 2 Lasers
System uses 96 wellplates
Sample Volume 20-200uL

Bio-Rad Luminex 200 Multiplexing Analyzer Flow Cytometry w/ XYP Stage, SD Module SOLDOUTBio-Rad Luminex 200 Multiplexing Analyzer Flow Cytometry w/ XYP Stage, SD Module SOLDOUT
Bio-Rad Luminex 200 Multiplexing Analyzer Flow Cytometry w/ XYP Stage, SD Module SOLDOUT
Laser type: Reporter Laser 532 nm and Classification Laser 635 nm
Number of lasers: 2 Lasers
System checks for type of bead and if bead has analytes attached to it
Sample handling: System uses 96 well-plates
Sample Volume: 20-200uL

Bio-Rad Luminex Bio-Plex 200 Suspension Array Analyzer w/ XYP, HTF SOLDOUTBio-Rad Luminex Bio-Plex 200 Suspension Array Analyzer w/ XYP, HTF SOLDOUT
Bio-Rad Luminex Bio-Plex 200 Suspension Array Analyzer w/ XYP, HTF SOLDOUT
Number of lasers: 2 Lasers
Laser type: Reporter Laser 532 nm and Classification Laser 635 nm
System checks for type of bead and if bead has analytes attached to it
Sample handling: System uses 96 well-plates
Sample Volume: 20-200uL

BioRad (Luminex) Bio-Plex 200 Flow Cytometer system w/Bio-Plex Manager 6.1SOLDOUTBioRad (Luminex) Bio-Plex 200 Flow Cytometer system w/Bio-Plex Manager 6.1SOLDOUT
BioRad (Luminex) Bio-Plex 200 Flow Cytometer system w/Bio-Plex Manager 6.1SOLDOUT
Number of lasers: 2 Lasers
Laser type: Reporter Laser 532 nm and Classification Laser 635 nm
System checks for type of bead and if bead has analytes attached to it
Sample handling: System uses 96 well-plates
Sample Volume: 20-200uL

Eppendorf / New Brunswick / Chemotec NucleoCounter NC-100 900-0005 Cell Counter SOLDOUTEppendorf / New Brunswick / Chemotec NucleoCounter NC-100 900-0005 Cell Counter SOLDOUT
Eppendorf / New Brunswick / Chemotec NucleoCounter NC-100 900-0005 Cell Counter SOLDOUT
counts mammalian cell nuclei stained with the DNA specific fluorescent dye, propidium iodide
Analysis volume approximately 2 µl
Analysis time 30 sec

Guava PCA Flow cytometer Cell Analysis System SOLDOUTGuava PCA Flow cytometer Cell Analysis System SOLDOUT
Guava PCA Flow cytometer Cell Analysis System SOLDOUT
Excitation wavelength - 532nm
Number of lasers - 1
Parameters measured: Forward scatter, Fluorescence detectors photomultipliers with 580 nm (PM1) and 675 nm (PM2) filters
Sample handling: Holds micro vials (Ex. Eppendorf 1.5ml)
Sample flow rate 12 µL/min to 60 µL/min

Guava Technologies / Millipore PCA-96 Cytometer with Windows 7 & Newest Software SOLDOUTGuava Technologies / Millipore PCA-96 Cytometer with Windows 7 & Newest Software SOLDOUT

Guava Technologies PCA Flow Cytometer SOLDOUTGuava Technologies PCA Flow Cytometer SOLDOUT
Guava Technologies PCA Flow Cytometer SOLDOUT
Excitation wavelength - 532nm
Number of lasers - 1
Parameters measured: Forward scatter, Fluorescence detectors photomultipliers with 580 nm (PM1) and 675 nm (PM2) filters
Sample handling: Holds micro vials (Ex. Eppendorf 1.5ml)
Sample flow rate 12 µL/min to 60 µL/min

Hach HIAC 9703+ Liquid Particle Counter SOLDOUTHach HIAC 9703+ Liquid Particle Counter SOLDOUT
Hach HIAC 9703+ Liquid Particle Counter SOLDOUT
Available Tests: Particle Counting
Particle size range: 2 um to 400 um
Number of Channels: 1
Flow Rate: 10 to 100 ml/min; Actual flow rate for the system is determined by the sensor’s flow rate
Temperature Range of Sample: 5 to 40 C

HIAC Hach Royco 9703 Liquid Particle Counter SOLDOUTHIAC Hach Royco 9703 Liquid Particle Counter SOLDOUT
HIAC Hach Royco 9703 Liquid Particle Counter SOLDOUT
Sample flow rate 10 to 100 mL/min1
Number of channels 65,536
Channel range Four (two for light scatter and two for light extinction)
Each channel range has 16,384 channels.

HP Hewlett Packard 35900E Multichannel Interface Module SOLDOUTHP Hewlett Packard 35900E Multichannel Interface Module SOLDOUT

Illumina BeadXpress Array Reader with Genome Studio Software Bead Express SOLDOUTIllumina BeadXpress Array Reader with Genome Studio Software Bead Express SOLDOUT
Illumina BeadXpress Array Reader with Genome Studio Software Bead Express SOLDOUT
Laser type: Red and Green laser
Number of lasers: Two
Parameters measured: Compares the fluorescence data measured from the scan against the target values entered at the beginning of
Sample handling: 96 well plate or strip well plates