Categories

DNA/RNA

Display: List /Grid
Show:
Sort By:
NanoString nCounter MAX Analyzer Made in 2017 Current DNA RNA Analysis System
NanoString nCounter MAX Analyzer Made in 2017 Current DNA RNA Analysis System
Level of Multiplexing: up to 800 targets
Sample Types Supported: total RNA, cell lysates in GITC, FFPE-derived total RNA, and PAXgene-lysed whole blood
Reaction Volume: up to 30 ul
Limit of Detection 0.5 fM Spike-in Control: 15 zeptomole spike-in control, Spike Correlation: R^2 >= 0.95
Digital Analyzer Throughput: 12 samples per 2.7 hours, Prep Station Throughput: 12 lanes per 2.5 hours
$38,995.00

Perkin Elmer chemagic MSM I Nucleic Acid DNA/RNA Isolation Workstation
Perkin Elmer chemagic MSM I Nucleic Acid DNA/RNA Isolation Workstation
Head type: 24 and 96
Volume per Channel: 24 channel 200 ul - 4 ml, 96 channel 10 ul - 400 ul
Rotating electromagnetic rod heads
Application: High throughput nucleic acid isolation
$8,995.00

Qiagen QIAcube Automated DNA/RNA Purification System Unit2
Qiagen QIAcube Automated DNA/RNA Purification System Unit2
Centrifuge: 10,640 RPM, Swinging bucket rotor (max 45deg), 12 rotor positions (max load 12x15g)
Shaker: Speed 100–2000 RPM, Amplitude 2 mm, Heating range of ambient temperature to 70C (158F), Ramp-up time of <5 minutes fr
Pipetting system: Syringe size 1 ml, Pipetting range 5–900ul, up to 12 samples per run
Power: 120/240 VAC, 50-60 Hz, 650 VA
Protocols/main application on this instrument: DNA purification, RNA purification, protein purification
$2,995.00

Qiagen QIAxcel Advanced DNA RNA Analyzer
Qiagen QIAxcel Advanced DNA RNA Analyzer
Protocols/Main Application: DNA and RNA analysis, genotyping and nucleic acid quality control analysis, streamlined electrophore
Power: 100-240VAC 50-60Hz 360VA
$5,295.00

Sage PippinHT DNA RNA Sequencer Unit2
Sage PippinHT DNA RNA Sequencer Unit2
Sample Capacity: 2 cassettes (24 samples)/run
Maximum Sample Load: 1.5 ug
Run Time: 25-50 min, 40 min for 500 bp
Target Range: 90 - 2000 bp
Min. Size Distribution: <8%
$4,995.00

Qiagen QIAcube Automated DNA/RNA Purification System SOLDOUTQiagen QIAcube Automated DNA/RNA Purification System SOLDOUT
Qiagen QIAcube Automated DNA/RNA Purification System SOLDOUT
Centrifuge: 10,640 RPM, Swinging bucket rotor (max 45deg), 12 rotor positions (max load 12x15g)
Shaker: Speed 100–2000 RPM, Amplitude 2 mm, Heating range of ambient temperature to 70C (158F), Ramp-up time of <5 minutes fr
Pipetting system: Syringe size 1 ml, Pipetting range 5–900ul, up to 12 samples per run
Power: 120/240 VAC, 50-60 Hz, 650 VA
Protocols/main application on this instrument: DNA purification, RNA purification, protein purification

Qiagen QIAcube Automated DNA/RNA Purification System SOLDOUTQiagen QIAcube Automated DNA/RNA Purification System SOLDOUT
Qiagen QIAcube Automated DNA/RNA Purification System SOLDOUT
Centrifuge: swing-out rotor, maximum 45dergrees, 12 rotor positions, max. 12,000 RPM
Shaker: 100 - 2000 RPM, amplitude 2 mm, heating range of ambient temperature to 70C (158F), ramp-up time of <5 minutes from a
Pipetting system: syringe size 1 ml, pipetting range 5 - 900 ul, up to 12 samples per run.
Power: 100-120 V AC, 50-60 Hz, 650 VA (North America and Japan), 220-240 V AC, 50-60 Hz, 650 VA (Europe)
Protocols/main application on this instrument: DNA purification, RNA purification, Protein purification

Qiagen QIAcube Automated DNA/RNA Purification System Unit3 SOLDOUTQiagen QIAcube Automated DNA/RNA Purification System Unit3 SOLDOUT
Qiagen QIAcube Automated DNA/RNA Purification System Unit3 SOLDOUT
Centrifuge: 10,640 RPM, Swinging bucket rotor (max 45deg), 12 rotor positions (max load 12x15g)
Shaker: Speed 100–2000 RPM, Amplitude 2 mm, Heating range of ambient temperature to 70C (158F), Ramp-up time of <5 minutes fr
Pipetting system: Syringe size 1 ml, Pipetting range 5–900ul, up to 12 samples per run
Power: 120/240 VAC, 50-60 Hz, 650 VA
Protocols/main application on this instrument: DNA purification, RNA purification, protein purification

Qiagen QIAcube cube DNA/RNA Purification System SOLDOUTQiagen QIAcube cube DNA/RNA Purification System SOLDOUT
Qiagen QIAcube cube DNA/RNA Purification System SOLDOUT
Centrifuge: swing-out rotor (maximum 45dergrees), 12 rotor positions (15 grams each), max. 10,640 RPM
Shaker: 100–2000 RPM, amplitude 2 mm, heating range of ambient temperature to 70C (158F), ramp-up time of <5 minutes from amb
Pipetting system: syringe size 1 ml, pipetting range 5–900 ul, up to 12 samples per run
Power: 110-120VAC
Protocols / main application on this instrument: DNA purification, RNA purification, protein purification

Qiagen QIAcube DNA/RNA Purification Sample Preparation SOLDOUTQiagen QIAcube DNA/RNA Purification Sample Preparation SOLDOUT
Qiagen QIAcube DNA/RNA Purification Sample Preparation SOLDOUT
Centrifuge: 10,640 RPM, Max load 12x15 g
Shaker: Speed 100–2000 RPM, Amplitude 2 mm, Heating range of ambient temperature to 70C (158F), Ramp-up time of <5 minutes fr
Pipetting system: Syringe size 1 ml, Pipetting range 5–900 ul, Capacity: Up to 12 samples per run
Power: 100-120 / 220-240 VAC, 50-60 Hz, 650 VA
Protocols / main application on this instrument: DNA purification, RNA purification, protein purification

Qiagen QIAcube DNA/RNA Purification Unit#2 SOLDOUTQiagen QIAcube DNA/RNA Purification Unit#2 SOLDOUT
Qiagen QIAcube DNA/RNA Purification Unit#2 SOLDOUT
Centrifuge: swing-out rotor (maximum 45dergrees), 12 rotor positions (15 grams each), max. 10,640 RPM
Shaker: 100–-2000 RPM, amplitude 2 mm, heating range of ambient temperature to 70C (158F), ramp-up time of <5 minutes from am
Pipetting system: syringe size 1 ml, pipetting range 5–900 ul, up to 12 samples per run
Power: 110-120VAC
Protocols / main application on this instrument: DNA purification, RNA purification, protein purification

Qiagen QIAcube DNA/RNA Purification Workstation Unit Number #3 SOLDOUTQiagen QIAcube DNA/RNA Purification Workstation Unit Number #3 SOLDOUT
Qiagen QIAcube DNA/RNA Purification Workstation Unit Number #3 SOLDOUT
Centrifuge: swing-out rotor (maximum 45dergrees), 12 rotor positions (15 grams each), max. 10,640 RPM
Shaker: 100-2000 RPM, amplitude 2 mm, heating range of ambient temperature to 70C (158F), ramp-up time of <5 minutes from amb
Pipetting system: syringe size 1 ml, pipetting range 5?900 ul, up to 12 samples per run
Power: 110-120VAC
Protocols / main application on this instrument: DNA purification, RNA purification, protein purification

Qiagen QIAsymphony SP Sample Preparation DNA RNA Purification QIA 9001297 SOLDOUTQiagen QIAsymphony SP Sample Preparation DNA RNA Purification QIA 9001297 SOLDOUT
Qiagen QIAsymphony SP Sample Preparation DNA RNA Purification QIA 9001297 SOLDOUT
Sample input volume: Up to 1000ul
Sample throughput: 1 to 96 per run
Dimensions: 128 x 103 x 73 cm

Qiagen QIAsymphony SP Sample Preparation DNA RNA Purification SOLDOUTQiagen QIAsymphony SP Sample Preparation DNA RNA Purification SOLDOUT
Qiagen QIAsymphony SP Sample Preparation DNA RNA Purification SOLDOUT
Sample input volume: Up to 1000ul
Sample throughput: 1 to 96 per run
Dimensions: 130 x 125 x 163 cm

Qiagen QIAsymphony SP/AS DNA Preparation System QIA Symphony SPAS SOLDOUTQiagen QIAsymphony SP/AS DNA Preparation System QIA Symphony SPAS SOLDOUT
Qiagen QIAsymphony SP/AS DNA Preparation System QIA Symphony SPAS SOLDOUT
Fully automated
Purify DNA, RNA, or proteins from up to 96 samples
Built-in flexibility for laboratory workflow integration
Sample volumes of up to 1000 µl

Qiagen QIAxcel Advanced DNA RNA Analyzer SOLDOUTQiagen QIAxcel Advanced DNA RNA Analyzer SOLDOUT
Qiagen QIAxcel Advanced DNA RNA Analyzer SOLDOUT
Protocols/Main Application: DNA and RNA analysis, genotyping and nucleic acid quality control analyses, streamlined electrophore
Power: 100-240VAC 50-60Hz 360VA

Sage PippinHT DNA RNA Sequencer SOLDOUTSage PippinHT DNA RNA Sequencer SOLDOUT
Sage PippinHT DNA RNA Sequencer SOLDOUT
Sample Capacity: 2 cassettes (24 samples)/run
Maximum Sample Load: 1.5 ug
Run Time: 25-50 min, 40 min for 500 bp
Target Range: 90 - 2000 bp
Min. Size Distribution: <8%


Boston Industries, Inc. © 2019