Shimadzu Nexera X2 SPD-M30A DAD Diode Array Detector / New Bulb
Shimadzu Nexera X2 SPD-M30A DAD Diode Array Detector / New Bulb
1024 element diode array with resolution of 0.5nm/element and < 1.4nm spectral resolution
Wavelength range of 190 to 700nm with a wavelength accuracy of +/-1nm is achieved through a Deuterium (D2) lamp
Baseline drift less than 0.5 x 10-3 AU/h (under specified conditions) and noise level of less than 0.4 x 10-6AU (under specific
Standard flow cell has an optical path length of 10mm and 1uL volume; maximum pressure 8 MPa/80 bar
Optional high-sensitivity cell with an optical path length of 85mm and capacity of 9uL can be installed
$7,995.00

Agilent DAD G1315B HPLC Diode Array Detector SOLDOUTAgilent DAD G1315B HPLC Diode Array Detector SOLDOUT
Agilent DAD G1315B HPLC Diode Array Detector SOLDOUT
Detection type: 1024-element photodiode array, Light source: Deuterium and tungsten lamps
Wavelength range: 190 - 950 nm
Short term noise: +/- 10-5 AU at 254 and 750 nm, Drift: 2 10-3 AU/hr at 254 nm, Linear absorbance range > 2 AU (upper l
Wavelength accuracy: +/- 1 nm, Wavelength bunching 1 - 400 nm
Slit width: 1, 2, 4, 8, 16 nm, Diode width < 1 nm

Agilent DAD G1315B HPLC Diode Array Detector unit 2 SOLDOUTAgilent DAD G1315B HPLC Diode Array Detector unit 2 SOLDOUT
Agilent DAD G1315B HPLC Diode Array Detector unit 2 SOLDOUT
Detection type: 1024-element photodiode array, Light source: Deuterium and tungsten lamps.
Wavelength range: 190-950 nm
Short term noise: +/- 1*10-5 AU at 254 and 750 nm, Drift: 2*10-3 AU/hr at 254 nm, Linear absorbance range > 2 AU (upper limit
Wavelength accuracy: +/- 1 nm, Wavelength bunching 1*400 nm
Slit width: 1, 2, 4, 8, 16 nm, Diode width < 1 nm

GE AKTA FPLC Detector UV-900 Monitor Module UV900 SOLDOUTGE AKTA FPLC Detector UV-900 Monitor Module UV900 SOLDOUT
GE AKTA FPLC Detector UV-900 Monitor Module UV900 SOLDOUT
Detector type: UV/Vis monitor
Max. flow rate: 100 ml/min, Max. pressure 2 MPa (20 bar, 290 psi), Backpressure Max. 0.5 bar at 2 ml/min
Light source: Xenon flash lamp, Lamp lifetime > 4000 hours, Control Stand alone or from a computer running, UNICORN 3.21 or h
Wavelength range: 190-700 nm in steps of 1 nm, 3 wavelengths simultaneously, Bandwidth 4 nm, Wavelength accuracy +/-2 nm, Wavele
Noise: (specified for 10 mm flow cell), 1, 2 Single wavelength short term (0.5-1 min) long term (1-10 min), Dual wavelengths

GE AKTA FPLC Detector UV-900 Monitor Unit3 SOLDOUTGE AKTA FPLC Detector UV-900 Monitor Unit3 SOLDOUT
GE AKTA FPLC Detector UV-900 Monitor Unit3 SOLDOUT
Detector type: UV/Vis monitor
Max. flow rate: 100 ml/min, Max. pressure 2 MPa (20 bar, 290 psi), Backpressure Max. 0.5 bar at 2 ml/min
Light source: Xenon flash lamp, Lamp lifetime > 4000 hours, Control Stand alone or from a computer running, UNICORN 3.21 or h
Wavelength range: 190-700 nm in steps of 1 nm, 3 wavelengths simultaneously, Bandwidth 4 nm, Wavelength accuracy +/-2 nm, Wave
Noise: (specified for 10 mm flow cell), 1, 2 Single wavelength short term (0.5-1 min) long term (1-10 min), Dual wavelengths

GE AKTA FPLC Detector UV-900 Monitor UV900 SOLDOUTGE AKTA FPLC Detector UV-900 Monitor UV900 SOLDOUT
GE AKTA FPLC Detector UV-900 Monitor UV900 SOLDOUT
Detector type: UV/Vis monitor
Max. flow rate: 100 ml/min, Max. pressure 2 MPa (20 bar, 290 psi), Backpressure Max. 0.5 bar at 2 ml/min
Light source: Xenon flash lamp, Lamp lifetime > 4000 hours, Control Stand alone or from a computer running, UNICORN 3.21 or h
Wavelength range: 190 - 700 nm in steps of 1 nm, 3 wavelengths simultaneously, Bandwidth 4 nm, Wavelength accuracy +/-2 nm, Wave
Noise: (specified for 10 mm flow cell), 1, 2 Single wavelength short term (0.5 - 1 min) long term (1 - 10 min), Dual wavelengths

GE AKTA FPLC Detector UV-900 Monitor UV900 Unit 2 SOLDOUTGE AKTA FPLC Detector UV-900 Monitor UV900 Unit 2 SOLDOUT
GE AKTA FPLC Detector UV-900 Monitor UV900 Unit 2 SOLDOUT
Detector type: UV/Vis monitor
Max. flow rate: 100 ml/min, Max. pressure 2 MPa (20 bar, 290 psi), Backpressure Max. 0.5 bar at 2 ml/m
Light source: Xenon flash lamp, Lamp lifetime > 4000 hours, Control Stand alone or from a computer running, UNICORN 3.21 or h
Wavelength range: 190–700 nm in steps of 1 nm, 3 wavelengths simultaneously, Bandwidth 4 nm, Wavelength accuracy +/-2 nm, Wavele
Noise: (specified for 10 mm flow cell), 1, 2 Single wavelength short term (0.5–1 min) long term (1–10 min), Dual wavelengths: sh

GE Pharmacia Biotech AKTA FPLC Detector UV-900 Monitor 18-1108-35 UV900 SOLDOUTGE Pharmacia Biotech AKTA FPLC Detector UV-900 Monitor 18-1108-35 UV900 SOLDOUT
GE Pharmacia Biotech AKTA FPLC Detector UV-900 Monitor 18-1108-35 UV900 SOLDOUT
Novel flow cell design and fiber-optic technology result in high sensitivity and high signal-to-noise ratio with minimal band br
Up to 3 wavelengths can be monitored simultaneously
Xenon flash lamp provides high sensitivity, continuous spectrum light, and long lamp lifetime
Simple to use either as part of ÄKTAdesign systems, see ÄKTA design - One Platform from Basic Research to Production, or as a st
Variable wavelength for detection in the range 190-700nm

GE Pharmacia Biotech AKTA FPLC Detector UV-900 Monitor SOLDOUTGE Pharmacia Biotech AKTA FPLC Detector UV-900 Monitor SOLDOUT
GE Pharmacia Biotech AKTA FPLC Detector UV-900 Monitor SOLDOUT
Detector type: UV/Vis monitor
Max. flow rate: 100 ml/min, Max. pressure 2 MPa (20 bar, 290 psi), Backpressure Max. 0.5 bar at 2 ml/min
Light source: Xenon flash lamp, Lamp lifetime > 4000 hours, Control Stand alone or from a computer running, UNICORN 3.21 or h
Wavelength range: 190–700 nm in steps of 1 nm, 3 wavelengths simultaneously, Bandwidth 4 nm, Wavelength accuracy +/-2 nm, Wavele
Noise: (specified for 10 mm flow cell), 1, 2 Single wavelength short term (0.5–1 min) long term (1–10 min), Dual wavelengths: sh

GE Pharmacia Biotech UV-900 Monitor AKTA FPLC Detector 18-1108-35 SOLDOUTGE Pharmacia Biotech UV-900 Monitor AKTA FPLC Detector 18-1108-35 SOLDOUT
GE Pharmacia Biotech UV-900 Monitor AKTA FPLC Detector 18-1108-35 SOLDOUT
Novel flow cell design and fiber-optic technology result in high sensitivity and high signal-to-noise ratio with minimal band br
Up to 3 wavelengths can be monitored simultaneously
Xenon flash lamp provides high sensitivity, continuous spectrum light, and long lamp lifetime
Simple to use either as part of ÄKTAdesign systems, see ÄKTA design - One Platform from Basic Research to Production, or as a st
Variable wavelength for detection in the range 190-700nm

Tested Agilent 1100 Diode Array Detector G1315B DAD HPLC Liquid Chromatography SOLDOUTTested Agilent 1100 Diode Array Detector G1315B DAD HPLC Liquid Chromatography SOLDOUT
Tested Agilent 1100 Diode Array Detector G1315B DAD HPLC Liquid Chromatography SOLDOUT
Detector type: DAD
Standard: 13 ul volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
Analog outputs Recorder/integrator: 100 mV or 1 V, output range0.001 – 2 AU, two outputs
Wavelength range: 190 – 950 nm, Linear absorbance range > 2 AU (upper limit)
Chromatography Type: HPLC

Tested, New Bulb - HP Agilent 1100 Series G1315A Diode Array Detector DAD SOLDOUTTested, New Bulb - HP Agilent 1100 Series G1315A Diode Array Detector DAD SOLDOUT