GE AKTA M-925 Mixer w/ 0.6ml Chamber
GE AKTA M-925 Mixer w/ 0.6ml Chamber
FPLC Mixer w/ .6mL mixing chamber
Max Pressure Range: 0.6mL chamber: 25MPa at 0.001-100ml/min (100 bar, 1450 psi)
Flow Range- 0.001-100ml/min
$289.00

GE Amersham pH/C-900 Monitor AKTA FPLC 18-1107-76 Conductivity Detector 5MPa
GE Amersham pH/C-900 Monitor AKTA FPLC 18-1107-76 Conductivity Detector 5MPa
Detector type: pH and conductivity
Accuracy: The greater of +/- 2% of full scale or +/- 10 uS/cm in the range 1 uS/cm-300 mS/cm +/- 0.1 pH unit, temperature compen
Flow Range: 100 ml./min
Response Time: Max. 10 s (0–95% of step) (pH measurements), Max. 3 s (0–95% of step) (Conductivity measurement)
Operating Pressure: Max. 50 bar (5 MPa) (725 psi)
$695.00

GE P-900 AKTA FPLC Pump 10ml heads unit 5
GE P-900 AKTA FPLC Pump 10ml heads unit 5
Flow Rate Range: isocratic mode 0.01–100 ml/min in steps of 10 ul/min, gradient mode 0.01–100 ml/min in steps of 10 ul/min,
Flow Rate Accuracy: 0.2–10.0 MPa +/-2% or 20 ul/min whichever is greater
Pressure Range: 0–10 MPa (100 bar, 1450 psi)
Gradient Composition: accuracy <+/-1% at 0.5–100 ml/min, reproducibility rsd <0.25% at 0.5–100 ml/min
Pressure Sensor: range 0–27.5 MPa, offset error <0.05 M, scale error <+/-2%
$2,995.00

GE P-900 AKTA FPLC Pump Pred 901 10ml heads unit 6
GE P-900 AKTA FPLC Pump Pred 901 10ml heads unit 6
Flow Rate Range: isocratic mode 0.01–100 ml/min in steps of 10 ul/min, gradient mode 0.01–100 ml/min in steps of 10 ul/min,
Flow Rate Accuracy: 0.2–10.0 MPa +/-2% or 20 ul/min whichever is greater
Pressure Range: 0–10 MPa (100 bar, 1450 psi)
Gradient Composition: accuracy <+/-1% at 0.5–100 ml/min, reproducibility rsd <0.25% at 0.5–100 ml/min
Pressure Sensor: range 0–27.5 MPa, offset error <0.05 M, scale error <+/-2%
$2,995.00

Agilent 1100 Variable Wavelength Detector G1314A VWD HPLC Liquid Chromatography SOLDOUTAgilent 1100 Variable Wavelength Detector G1314A VWD HPLC Liquid Chromatography SOLDOUT
Agilent 1100 Variable Wavelength Detector G1314A VWD HPLC Liquid Chromatography SOLDOUT
Detector type: VWD
Standard: 14-ul volume, 10-mm cell path length and 40 bar (588 psi) pressure maximum
Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, one output
Wavelength range 190–600 nm
Chromatography Type: HPLC

Agilent 1100 Variable Wavelength G1314A VWD HPLC Detector SOLDOUTAgilent 1100 Variable Wavelength G1314A VWD HPLC Detector SOLDOUT
Agilent 1100 Variable Wavelength G1314A VWD HPLC Detector SOLDOUT
Detector type: VWD
Standard: 14-ul volume, 10-mm cell path length and 40 bar (588 psi) pressure maximum
Recorder/integrator: 100 mV or 1 V, output range 0.001 - 2 AU, one output
Wavelength range: 190 - 600 nm
Chromatography Type: HPLC

Agilent DAD G1315B HPLC Diode Array Detector SOLDOUTAgilent DAD G1315B HPLC Diode Array Detector SOLDOUT
Agilent DAD G1315B HPLC Diode Array Detector SOLDOUT
Detection type: 1024-element photodiode array, Light source: Deuterium and tungsten lamps
Wavelength range: 190 – 950 nm
Short term noise: +/- 1 ? 10-5 AU at 254 and 750 nm, Drift: 2 ? 10-3 AU/hr at 254 nm, Linear absorbance range > 2 AU (upper l
Wavelength accuracy: +/- 1 nm, Wavelength bunching 1 – 400 nm
Slit width: 1, 2, 4, 8, 16 nm, Diode width < 1 nm

Agilent DAD G1315B HPLC Diode Array Detector unit 2 SOLDOUTAgilent DAD G1315B HPLC Diode Array Detector unit 2 SOLDOUT
Agilent DAD G1315B HPLC Diode Array Detector unit 2 SOLDOUT
Detection type: 1024-element photodiode array, Light source: Deuterium and tungsten lamps.
Wavelength range: 190?-950 nm
Short term noise: +/- 1*10-5 AU at 254 and 750 nm, Drift: 2*10-3 AU/hr at 254 nm, Linear absorbance range > 2 AU (upper limit
Wavelength accuracy: +/- 1 nm, Wavelength bunching 1 ? 400 nm
Slit width: 1, 2, 4, 8, 16 nm, Diode width < 1 nm

Antec Decade II 2 SCC 171.0035 Electrochemical Detector ECD for HPCL Waters 2465 SOLDOUTAntec Decade II 2 SCC 171.0035 Electrochemical Detector ECD for HPCL Waters 2465 SOLDOUT
Antec Decade II 2 SCC 171.0035 Electrochemical Detector ECD for HPCL Waters 2465 SOLDOUT
Electrochemical Detector
2 Channel
Auto, DC, Pulse, Scan Modes
UPLC, HPLC or LC
Column/flowcell oven

Antec Decade II 2 TCC 171.0039 Electrochemical Detector ECD for HPLC Waters 2465 SOLDOUTAntec Decade II 2 TCC 171.0039 Electrochemical Detector ECD for HPLC Waters 2465 SOLDOUT
Antec Decade II 2 TCC 171.0039 Electrochemical Detector ECD for HPLC Waters 2465 SOLDOUT
Electrochemical Detector
3 channel
Auto, DC, Pulse, and Scan modes
UPLC, HPLC or LC
C2V Contol Valve

CTC LC PAL Leap Autosampler with CoolStack, Wash Station, Supply Bottles, Valve SOLDOUTCTC LC PAL Leap Autosampler with CoolStack, Wash Station, Supply Bottles, Valve SOLDOUT
CTC LC PAL Leap Autosampler with CoolStack, Wash Station, Supply Bottles, Valve SOLDOUT
Chromatography type - HPLC A
Sample Size - 1 to 50ul per sample with current setup A
Injection Method - 6 position valve box for up to 5,000psi injections A
Sample Storage - Coolstack with external digital controller A

GE AKTA FPLC Detector UV-900 Monitor 10mm flow cell SOLDOUTGE AKTA FPLC Detector UV-900 Monitor 10mm flow cell SOLDOUT
GE AKTA FPLC Detector UV-900 Monitor 10mm flow cell SOLDOUT
Detector type: UV/Vis monitor
Max. flow rate: 100 ml/min, Max. pressure 2 MPa (20 bar, 290 psi), Backpressure Max. 0.5 bar at 2 ml/min
Light source: Xenon flash lamp, Lamp lifetime > 4000 hours, Control Stand alone or from a computer running, UNICORN 3.21 or h
Wavelength range: 190–700 nm in steps of 1 nm, 3 wavelengths simultaneously, Bandwidth 4 nm, Wavelength accuracy +/-2 nm, Wave
Noise: (specified for 10 mm flow cell), 1, 2 Single wavelength short term (0.5–1 min) long term (1–10 min), Dual wavelengths

GE AKTA FPLC Detector UV-900 Monitor 2mm flow cell Unit 3 SOLDOUTGE AKTA FPLC Detector UV-900 Monitor 2mm flow cell Unit 3 SOLDOUT
GE AKTA FPLC Detector UV-900 Monitor 2mm flow cell Unit 3 SOLDOUT
Detector type: UV/Vis monitor
Max. flow rate: 100 ml/min, Max. pressure 2 MPa (20 bar, 290 psi), Backpressure Max. 0.5 bar at 2 ml/min
Light source: Xenon flash lamp, Lamp lifetime > 4000 hours, Control Stand alone or from a computer running, UNICORN 3.21 or h
Wavelength range: 190–700 nm in steps of 1 nm, 3 wavelengths simultaneously, Bandwidth 4 nm, Wavelength accuracy +/-2 nm, Wave
Noise: (specified for 10 mm flow cell), 1, 2 Single wavelength short term (0.5–1 min) long term (1–10 min), Dual wavelengths

GE AKTA FPLC Detector UV-900 Monitor Unit4 2mm flow cell SOLDOUTGE AKTA FPLC Detector UV-900 Monitor Unit4 2mm flow cell SOLDOUT
GE AKTA FPLC Detector UV-900 Monitor Unit4 2mm flow cell SOLDOUT
Detector type: UV/Vis monitor
Max. flow rate: 100 ml/min, Max. pressure 2 MPa (20 bar, 290 psi), Backpressure Max. 0.5 bar at 2 ml/min
Light source: Xenon flash lamp, Lamp lifetime > 4000 hours, Control Stand alone or from a computer running, UNICORN 3.21 or h
Wavelength range: 190–700 nm in steps of 1 nm, 3 wavelengths simultaneously, Bandwidth 4 nm, Wavelength accuracy +/-2 nm, Wave
Noise: (specified for 10 mm flow cell), 1, 2 Single wavelength short term (0.5–1 min) long term (1–10 min), Dual wavelengths

GE AKTA FPLC Detector UV-900 Monitor UV900 10mm flow cell SOLDOUTGE AKTA FPLC Detector UV-900 Monitor UV900 10mm flow cell SOLDOUT
GE AKTA FPLC Detector UV-900 Monitor UV900 10mm flow cell SOLDOUT
Detector type: UV/Vis monitor
Max. flow rate: 100 ml/min, Max. pressure 2 MPa (20 bar, 290 psi), Backpressure Max. 0.5 bar at 2 ml/min
Light source: Xenon flash lamp, Lamp lifetime > 4000 hours, Control Stand alone or from a computer running, UNICORN 3.21 or h
Wavelength range: 190–700 nm in steps of 1 nm, 3 wavelengths simultaneously, Bandwidth 4 nm, Wavelength accuracy +/-2 nm, Wave
Noise: (specified for 10 mm flow cell), 1, 2 Single wavelength short term (0.5–1 min) long term (1–10 min), Dual wavelengths

GE Amersham pH/C-900 Monitor AKTA FPLC 18-1107-76 Conductivity Detector Unit2 SOLDOUTGE Amersham pH/C-900 Monitor AKTA FPLC 18-1107-76 Conductivity Detector Unit2 SOLDOUT
GE Amersham pH/C-900 Monitor AKTA FPLC 18-1107-76 Conductivity Detector Unit2 SOLDOUT
Detector type: pH and conductivity
Flow Range: 100 ml./min
Accuracy: The greater of ± 2% of full scale or ± 10 µS/cm in the range 1 µS/cm-300 mS/cm ± 0.1 pH unit, temperature compensated,
Response Time: Max. 10 s (0–95% of step) (pH measurements), Max. 3 s (0–95% of step) (Conductivity measurement)
Operating Pressure: Max. 50 bar (5 MPa) (725 psi)

Gilson 155 UV/VIS HPLC Detector SOLDOUTGilson 155 UV/VIS HPLC Detector SOLDOUT
Gilson 155 UV/VIS HPLC Detector SOLDOUT
Detector type: Ultraviolet and visual spectrum
Flow range: recommended operating flow rate range 0.1–10 mL/min
Input/Output: single channel flow cell
Sensitivity Range: 0.001 to 2.0 AU. Sensitivity is adjustable in increments of 0.001 AU
Lamps: UV lamp Deuterium, Visible lamp Tungsten/halogen lamp

Gilson 155 UV/VIS HPLC Detector Unit2 SOLDOUTGilson 155 UV/VIS HPLC Detector Unit2 SOLDOUT
Gilson 155 UV/VIS HPLC Detector Unit2 SOLDOUT
Detector type: Ultraviolet and visual spectrum
Flow range: recommended operating flow rate range 0.1–10 mL/min
Input/Output: single channel flow cell
Sensitivity Range: 0.001 to 2.0 AU. Sensitivity is adjustable in increments of 0.001 AU
Lamps: UV lamp Deuterium, Visible lamp Tungsten/halogen lamp

Gilson PREP ELS II 2 ELSD Evaporative Light Scattering Detector - System SOLDOUTGilson PREP ELS II 2 ELSD Evaporative Light Scattering Detector - System SOLDOUT
Gilson PREP ELS II 2 ELSD Evaporative Light Scattering Detector - System SOLDOUT
Thermo-Split Technology precisely controls temperature of spray chamber and drift tube separately
Output Signal0 – 10mV DC or 0 – 5V DC, dependent on full-scale and calibration settings
Light Source670 nM laser diode, < 5 mW
Liquid Contact Materials include Stainless steel, glass, anodized aluminum and Teflon®

Gilson PREP ELS II 2 ELSD Evaporative Light Scattering Detector SOLDOUTGilson PREP ELS II 2 ELSD Evaporative Light Scattering Detector SOLDOUT
Gilson PREP ELS II 2 ELSD Evaporative Light Scattering Detector SOLDOUT
Thermo-Split Technology precisely controls temperature of spray chamber and drift tube separately
Output Signal0 – 10mV DC or 0 – 5V DC, dependent on full-scale and calibration settings
Light Source670 nM laser diode, < 5 mW
Liquid Contact Materials include Stainless steel, glass, anodized aluminum and Teflon®

Gilson UV/VIS 151 Detector SOLDOUTGilson UV/VIS 151 Detector SOLDOUT

Gilson UV/VIS 155 Detector SOLDOUTGilson UV/VIS 155 Detector SOLDOUT

Polymer Laboratories PL-ELS 1000 Evaporative Light Scattering Detector ELSD SOLDOUTPolymer Laboratories PL-ELS 1000 Evaporative Light Scattering Detector ELSD SOLDOUT

Polymer Laboratories PL-ELS 2100 Ice ELSD Evaporative Light Scattering Detector SOLDOUTPolymer Laboratories PL-ELS 2100 Ice ELSD Evaporative Light Scattering Detector SOLDOUT
Polymer Laboratories PL-ELS 2100 Ice ELSD Evaporative Light Scattering Detector SOLDOUT
Measurement Method: light scattering, Detection: photomultiplier
Temperature Range: evaporator 10-80C, nebulizer ambient to 90C
Nebulizer Gas: typical inlet pressure 60-100psi, maximum inlet pressure 100psi, gas flow rate 0-3.25SLM
Eluent Flow Rate: 0-5ml/min

Sedere / Schimadzu Sedex 75 ELSD Evaporative Light Scattering Detector SOLDOUTSedere / Schimadzu Sedex 75 ELSD Evaporative Light Scattering Detector SOLDOUT