Teledyne CombiFlash PurIon S Mass Spectrometer
âIonization Modes: âPositive or Negative
Operation Range: 10 - 1200Da (m/z)
Scan Rate: 10000 AMU s-1 (compatible with UPLC)
Mass accuracy and resolution is adequate to provide accurate (A+1) and (A+2) isotope peaks
Compatible Units: âCombiFlash EZ Prep, CombiFlash NextGen 100 NextGen 300, NextGen 300+, ACCQPrep HP125
$17,995.00
$5,995.00
Waters Synapt G2 High Definition Mass Spectrometer Pred Si SOLDOUT
Measurement of mass to 4 decimal places (exact mass)
Orthogonal time-of-flight (oa-TOF) mass spectrometer
High-resolution (above 40,000 FWHM)
Waters MicroMass ZQ Mass Spectrometer SOLDOUT
Sources: ESCi and APCI
Mass Spec Type: Quadrupole
Scan Speed Range: 197 to 3980 amu/sec
Spectrometry Type: HPLC-MS
Waters MICROMASS ZQ Mass Spectrometer SOLDOUT
Mass Spectrometry Type: Quadrupole
Scan Speeds: up to 5000 amu/sec
Spectrometry Types: LC/MS/MS
Ion Source: ESI or APcI
Waters Micromass ZQ 2000 Mass Spectrometer 186002000 HPLC/MS SOLDOUT
Mass Spec Type: Quadrupole
Scan speed range: 197 to 3980 amu/sec
Spectrometry type: HPLC-MS
Sources: ESCi and APCI
Waters Micromass LCT Premier XE TOF Mass Spectrometer LC/MS Unit2 SOLDOUT
Mass Spectrometry Type: LC-MS
Flow Rate: 1 mL/min
Ion Source: APPI
Mass Range: up to 1,000 m/z
LCT Premier orthogonal acceleration time of flight (oa-TOF) mass spectrometer
Waters Micromass LCT Premier XE Mass Spectrometer TOF LC/MS SOLDOUT
LCT Premier orthogonal acceleration time of flight (oa-TOF) mass spectrometer
Mass Range: up to 1,000 m/z
Spectrometry Type: LC-MS
Ion Source: APPI
Waters Micromass LCT Premier Mass Spectrometer TOF LC/MS SOLDOUT
Mass spec type: TOF
Min Scan rate: 0.01 seconds
Mass accuracy: +/- 20 mDa
Ionization Source: ESI with LockSpray and Reference Probe
Mass Range: up to 30,000 Da
TSI macroIMS 3080 3480 3776C Macro ion Spectrometer w/ 3085 Analyzer Pred 3982 SOLDOUT
Mass Spec Type: Macroion Mobility Spectrometer
Differential Mobility Analyzer (DMA) Included: Nano (Model 3085)
Detector Aerosol flow rate: 50 cm3/min (0.005 L/min)
Particle size range: Nano DMA 2.5-100 nm
Particle type: Solids and nonvolatile liquids
Thermo FAIMS Waveform Generator Wave Form for LC/MS Mass Spectrometry SOLDOUT
Type of Mass spec: removed from TSQ Quantum Ultra
Compensation voltage scan range: -200 to +200 V
Dispersion voltage: -4000 to -5000 V (positive ions), +4000 to +5000 V (negative Ions)
Total gas flow: 2.5 to 10 L/min at 50% He
Electrode temperatures: 30 C to 120 C
Teledyne Isco CombiFlash PurIon Mass Spectrometer SOLDOUT
Mass Spec Type: Quadrupole
Mass Accuracy: 1 Dalton Resolution
Ion Source: Electrospray Ionization (ESI)
Mass Range: 50 â 1200 Dalton
Bruker Daltonics 21375.00175 MicrOTOF Focus Mass Spectrometer with ESI Source SOLDOUT
Focus Option Intergrated
Mass resolution exceeding 15,000 FWHM
ESI source
Agilent G1956B LC/MSD SL Mass Spectrometer W/ G1948A Source SOLDOUT
Mass Range: 50-3000 m/z
Mass Axis Stability: + or 0.2u over 8 hours
Mass Accuracy: + or 0.2u
Agilent G1956B LC/MSD Quadrupole Mass Spectrometer Unit2 SOLDOUT
Mass Spec Type: Quadrupole analyzer
Scan step size: 0.10 m/z min
Spectrometry Type: LC/MSD
Source: Agilent G1948A API ElectroSpray
Mass Range: 0-3000 m/z