Business days 9am - 6pm
Mass Spectrometers
Teledyne CombiFlash PurIon S Mass Spectrometer
âIonization Modes: âPositive or Negative
Operation Range: 10 - 1200Da (m/z)
Scan Rate: 10000 AMU s-1 (compatible with UPLC)
Mass accuracy and resolution is adequate to provide accurate (A+1) and (A+2) isotope peaks
Compatible Units: âCombiFlash EZ Prep, CombiFlash NextGen 100 NextGen 300, NextGen 300+, ACCQPrep HP125
$17,995.00
AB MDS SCIEX API 3000 Triple Quadrupole LC Mass Spectrometer 018444 Pred to 4000 SOLDOUT
Mass Spec Type: Triple Quadrupole
Mass Range: up to 3,000m/z
Spectrometry Type: LC-MS
Ion Sources: Heated Nebulizer (APCI) and Turbo Ion Spray (ESI)
AB MDS Sciex Tempo LC MALDI Spotting System w/ Eksigent Spotter and CTC Injector SOLDOUT
Spotting speed: Up to 4 Hz
Droplet size: 1 nL 5 uL
Spot density: up to 10,000 spots per target with less than 1 mm spot-to-spot pitch and high accuracy over-spotting capabilities
Plate format and plate tray capacity: 4800 MALDI TOF/TOF Analyzer (8-plate capacity), 4700 ProteomicsAnalyzer and QSTAR XL syst
Flow range: 200 nL/min 20 uL/min
ABI MDS Sciex 018444 API 3000 Triple Quad Mass Spectrometer LC-MS Pred. API4000 SOLDOUT
Mass Spec Type: Triple Quadrupole
Spectrometry Type: LC-MS
Mass Range: up to 3,000m/z
Ion Source: Turbo Ion Spray (ESI)
Advion Expression L CMS Compact Mass Spectrometer SOLDOUT
Mass Range: 10-2,000 m/z
Acquisition Speed: 10,000 m/z units/sec
Sensitivity(ESI): 10 pg reserpine (FIA - 5 uL injection at 100 uL/min) 100:1 S/N (RMS) with SIM of m/z 609.3
Accuracy: +/- 0.1 m/z units of the entire acquisition range
Stability: 0.1 m/z units @ 1,200 m/z, over 12 hour period @ operating temperature of 20C +/-1C
Advion Expression L CMS Compact Mass Spectrometer SOLDOUT
Mass Range: 10-2,000 m/z
Acquisition Speed: 10,000 m/z units/sec
Sensitivity(ESI): 10 pg reserpine (FIA - 5 uL injection at 100 uL/min) 100:1 S/N (RMS) with SIM of m/z 609.3
Accuracy: +/- 0.1 m/z units of the entire acquisition range
Stability: 0.1 m/z units @ 1,200 m/z, over 12 hour period @ operating temperature of 20C +/-1C
Agilent 1100 Mass Spectrometer G1956B Single Quadrupole LC/MSD w/ G1948A API SOLDOUT
Mass Spec Type: Quadrupole analyzer
Scan step size: 0.10 m/z min
Spectrometry Type: LC/MSD
Source: Agilent G1948A API ElectroSpray
Mass Range: 0-3000 m/z
Agilent G1956B LC/MSD Quadrupole Mass Spectrometer Unit2 SOLDOUT
Mass Spec Type: Quadrupole analyzer
Scan step size: 0.10 m/z min
Spectrometry Type: LC/MSD
Source: Agilent G1948A API ElectroSpray
Mass Range: 0-3000 m/z
Agilent G1956B LC/MSD SL Mass Spectrometer W/ G1948A Source SOLDOUT
Mass Range: 50-3000 m/z
Mass Axis Stability: + or 0.2u over 8 hours
Mass Accuracy: + or 0.2u
Bruker Daltonics 21375.00175 MicrOTOF Focus Mass Spectrometer with ESI Source SOLDOUT
Focus Option Intergrated
Mass resolution exceeding 15,000 FWHM
ESI source
Teledyne Isco CombiFlash PurIon Mass Spectrometer SOLDOUT
Mass Spec Type: Quadrupole
Mass Accuracy: 1 Dalton Resolution
Ion Source: Electrospray Ionization (ESI)
Mass Range: 50 â 1200 Dalton
Thermo FAIMS Waveform Generator Wave Form for LC/MS Mass Spectrometry SOLDOUT
Type of Mass spec: removed from TSQ Quantum Ultra
Compensation voltage scan range: -200 to +200 V
Dispersion voltage: -4000 to -5000 V (positive ions), +4000 to +5000 V (negative Ions)
Total gas flow: 2.5 to 10 L/min at 50% He
Electrode temperatures: 30 C to 120 C