Thermo EASY-nLC II Nano-Flow UHPLC LC110 Pred 1200/LC140
Flow Range (gradient) 20 to 2000 nL/min; Recommended: 100 to 1000 nL/min
Pressure Range: 0 to 300 bar
Autosampler Sample Pickup Volume Range: 0.1 to 8uL with a 10uL loop
Injection Reproducibility: 0.2% at 5uL pickup, 3.0% at 0.1uL pickup
Injection Linearity: 0.9985 at 0.5 to 10uL injection volume
$7,995.00
Thermo Scientific EASY-nLC II Nano-Flow UHPLC LC110 Pred. to 1200 SOLDOUT
Flow range (gradient): 20 to 2000 nL/min, Recommended: 100 to 1000 nL/min
Pressure range: 0 to 300 bar
Autosampler sample pickup volume range: 0.1 to 8 uL with a 10 uL loop
Injection reproducibility: 0.2% at 5 uL pickup, 3.0% at 0.1 uL pickup
Injection linearity: 0.9985 at 0.5 to 10 uL injection volume
Thermo Scientific EASY-nLC II Nano-Flow HPLC LC110 Pred. to 1200 LC140 Unit2 SOLDOUT
Flow range (gradient) 20 to 2000 nL/min, Recommended: 100 to 1000 nL/min
Pressure range: 0 to 300 bar
Autosampler sample pickup volume range: 0.1 to 8 uL with a 10 uL loop
Injection reproducibility: 0.2% at 5 uL pickup, 3.0% at 0.1 uL pickup
Injection linearity 0.9985 at 0.5 to 10 uL injection volume
Thermo Easy-nLC II Liquid Chromatography Pred. to 1200 SOLDOUT
Flow range (gradient): 20 to 2000 nL/min, Recommended: 100 to 1000 nL/min
Pressure range: 0 to 300 bar
Autosampler sample pickup volume range: 0.1 to 18 uL with the standard 20 uL loop, 0.1 to 48 uL with a 50 uL loop
Injection reproducibility: 0.2% at 5 uL pickup, 3.0% at 0.1 uL pickup
Injection linearity: 0.9985 at 0.5 to 10 uL injection volume
Tested - Agilent G1379A Micro Degasser Vacuum Analytical HPLC Capillary LC SOLDOUT
Chromatography Type: Analytical HPLC
Volume Range: 0-5 mL/Min per channel
Degasser Type: Inline Vacuum Degasser
Solvent Channels: 4
Tested - Agilent 1100 Column Compartment G1316A COLCOM HPLC SOLDOUT
Chromatography Type: HPLC
10 degrees below ambient to 80 C
Column capacity: Three 30 cm
Temperature stability 0.15 C, Temperature accuracy 0.8 C, 0.5 C - with calibration
Gilson HPLC System w/ GX-281 Liquid Handler Autosampler 334 & 334 pumps SOLDOUT
Sampler Type: X/Y/Z with stationary rack design, Probe Positioning Performance: Accuracy +/- 0.05 mm in X/Y/Z dimensions, Repeat
Arm Speed: 0.01 to 600.00 mm/sec in X dimension, 0.01 to 600.00 mm/sec in Y dimension, 0.01 to 125.00 mm/sec in Z dimension
Data Acquisition: An input channel for analog-to-digital conversion, Input impedance: More than 100K ohms, Input voltage range:
Locator Plate Capacity Up to six Code 200-series racks
Software Control Computer control via RS-232 or GSIOC and TRILUTION software
Gilson GX-281 Liquid Handler w/ 333,334 Pumps, UV/VIS-155 Detector SOLDOUT
Sampler Type: X/Y/Z with stationary rack design
Probe Positioning Performance: Accuracy: +/- 0.05 mm in X/Y/Z, Repeatability: +/- 0.025 mm in X/Y/Z
GX Solvent System: 50psi back pressure, flow rate preparative 1 uL/min up to 50 mL/min
UV/VIS 155 Detector: flow cell 104441, path 0.2mm, volume 0.7uL, 500 PSI, 3.45 MPa
Software: commands can be issued via GSIOC or RS-232
Gilson GX-281 Liquid Handler w/ 333,334 Pumps, UV/VIS-155 Detector / Prep Scale SOLDOUT
Sampler Type: X/Y/Z with stationary rack design
Probe Positioning Performance: accuracy +/- 0.05 mm in X/Y/Z dimensions, Repeatability: +/- 0.025 mm in X/Y/Z dimensions
Arm Speed: 0.01 to 600.00 mm/sec in X dimension, 0.01 to 600.00 mm/sec in Y dimension, 0.01 to 125.00 mm/sec in Z dimension
Data Acquisition: an input channel for analog-to-digital conversion, Input impedance: more than 100K ohms, Input voltage range:
Locator Plate Capacity: up to six Code 200-series racks
Gilson GX-281 Liquid Handler System w/ Gilson 333/334 pumps & UVIS 155 Detector SOLDOUT
Sampler Type: X/Y/Z with stationary rack design
Probe Positioning Performance: accuracy +/- 0.05 mm in X/Y/Z dimensions, Repeatability: +/- 0.025 mm in X/Y/Z dimensions
Arm Speed: 0.01 to 600.00 mm/sec in X dimension, 0.01 to 600.00 mm/sec in Y dimension, 0.01 to 125.00 mm/sec in Z dimension
Data Acquisition: an input channel for analog-to-digital conversion, Input impedance: more than 100K ohms, Input voltage range:
Locator Plate Capacity: up to six Code 200-series racks
Gilson GX-281 Liquid Handler / Prep Scale HPLC System SOLDOUT
Sampler Type: X/Y/Z with stationary rack design
Probe Positioning Performance: Accuracy +/- 0.05 mm in X/Y/Z dimensions, Repeatability +/- 0.025 mm in X/Y/Z dimensions
Arm Speed: 0.01 to 600.00 mm/sec in X dimension, 0.01 to 600.00 mm/sec in Y dimension, 0.01 to 125.00 mm/sec in Z dimension
Data Acquisition: An input channel for analog-to-digital conversion, Input impedance More than 100K ohms, Input voltage range -1
Locator Plate Capacity Up to six Code 200-series racks
Gilson GX-281 Automated Liquid Handler PREP Scale HPLC 334 & 333 Pumps 151 UVS SOLDOUT
Sample LoadingCapacity: 15 g/injection
Maximum Injection Pressure: 3,000 psi (207 bar)
Flow Rate: 1200 mL/min
Maximum PumpPressure: 3,040 psi (210 bar)
Optimal Column Size: 4.6100 mm
Gilson GX-281 Automated Liquid Handler PREP Scale HPLC 334 & 333 pump System 3 SOLDOUT
Sampler Type: X/Y/Z with stationary rack design
Gilson 333 Prep Scale HPLC pump
Gilson 334 Prep Scale HPLC pump
Prep Scale HPLC Chromatography
Gilson UV/VIS detector
Gilson GX-281 Automated Liquid Handler PREP Scale HPLC 333 & 334 Pumps System 4 SOLDOUT
Sample LoadingCapacity: 15 g/injection
Maximum Injection Pressure: 3,000 psi (207 bar)
Flow Rate: 1200 mL/min
Maximum PumpPressure: 3,040 psi (210 bar)
Optimal Column Size: 4.6100 mm
Eksigent NanoLC Ultra 2D System HPLC w/ cHiPLC, AS-2 Autosampler Pred NanoLC 400 SOLDOUT
Carry-over: <0.05%
The NanoLC-Ultra 2D (two gradients) system, Injection volume: programmable from 100 nl to 10 µl with standard 10 µl loop. Larger
Sample tray cooling 4C to ambient -3C (+/-2 C)
Standard flow rate ranges: Loading pump: 1-30 ul/min, Nano gradient: 50-500 nl/min (up to 1000 nl/min at reduced maximum pressur
BioRad BioLogic LP LC Low-Pressure Liquid Chromatography SOLDOUT
Flow range: 0.1-40 ml/min, Maximum counterpressure: 30psi
UV: Single channel, 280/254 nm with auto zero, Detection range: 0.001-2 AUFS; Conductivity : Detection range: 0.5-500 mS/cm FS
Software: BioLogic software ver1.03
Fraction collector: BioFrac
Bio-Rad BioLogic LP Chromatography System w/ BioFrac SOLDOUT
Flow range: 0.1-40 ml/min, Maximum counterpressure: 30psi
Detectors: UV - Single channel, 280/254 nm with auto zero, Detection range: 0.001-2 AUFS, Conductivity - Detection range: 0.5-50
Software: LP data viewer Version 1.03
Fraction collector: BioFrac
Agilent HP G1322A HPLC Vacuum Degasser SOLDOUT
Maximum flow rate: 0 - 10 ml/min per channel5 - 10 ml/min at reduced degassing performance
Number of channels: 4
Internal volume per channel Typically 1 ml per channel
Materials in contact with solvent: PTFE, FEP, PEEK
pH range: 1 - 14