GE P-900 AKTA FPLC Pump
GE P-900 AKTA FPLC Pump
Flow rate range: isocratic mode 0.01–100 ml/min in steps of 10 ul/min, gradient mode 0.01–100 ml/min in steps of 10 ul/min, doub
Pressure range: 0–10 MPa (100 bar, 1450 psi)
Gradient composition: accuracy <+/-1% at 0.5–100 ml/min, reproducibility rsd <0.25% at 0.5–100 ml/min
Pressure sensor: Range 0–27.5 MPa, Offset error <0.05 M, Scale error <+/-2%
Control: Stand alone or from a PC running UNICORN version, 2.20 or higher, through UniNet 1 cable connection
$4,295.00

GE Pharmacia Biotech AKTA FPLC Detector UV-900 Monitor
GE Pharmacia Biotech AKTA FPLC Detector UV-900 Monitor
Detector type: UV/Vis monitor
Max. flow rate: 100 ml/min, Max. pressure 2 MPa (20 bar, 290 psi), Backpressure Max. 0.5 bar at 2 ml/min
Light source: Xenon flash lamp, Lamp lifetime > 4000 hours, Control Stand alone or from a computer running, UNICORN 3.21 or h
Wavelength range: 190–700 nm in steps of 1 nm, 3 wavelengths simultaneously, Bandwidth 4 nm, Wavelength accuracy +/-2 nm, Wavele
Noise: (specified for 10 mm flow cell), 1, 2 Single wavelength short term (0.5–1 min) long term (1–10 min), Dual wavelengths: sh
$4,295.00

GE AKTA FPLC Flash Purification
GE AKTA FPLC Flash Purification
Flow rate range: isocratic mode - 0.05–20 ml/min in steps of 10 ul/min, gradient mode - 0.1–20 ml/min in steps of 10 ul/min, Pre
pH stability range: 1–13 (1–14 < 1 day exposure)
Flow rate reproducibility: flow rate 0.5–10 ml/min - rsd < 0.2%, flow rate 10–20 ml/min - rsd < 0.5%, Gradient composition
Conductivity range: 1 uS/cm to 999.9 mS/cm, Conductivity flow cell Flow rate - 0–100 ml/min, Max. pressure - 5 MPa (50 bar, 725
Monitor UPC-900 UV measurement: Absorbance range - 0.01–5.0 AU (full scale), Autozero range - -0.2–2.0 AU, Baseline adjust - Adj
$7,995.00

GE Amersham AKTA Explorer 100 FPLC Flash Purification Pred. Avant
GE Amersham AKTA Explorer 100 FPLC Flash Purification Pred. Avant
P-900 pump Flow rate: 0.01-100ml per minute
UV/Vis - pH - conductivity
Software: Unicorn version 5.11
Fraction collector: Frac-950
Accessories: P-960 sample pump, M-925 mixer w/ 2ml mixing chamber, Conductivity sensor, Two switch valves, 128 tube fraction rac
$12,995.00

GE Amersham Pharmacia Biotech HPLC P-920 Pump AKTA FPLC Component
GE Amersham Pharmacia Biotech HPLC P-920 Pump AKTA FPLC Component
The P-920 pump can be controlled as a stand-alone unit using the front knobs, or as the system pump in ÄKTAFPLC
Operating Pressure Max. 50 bar (5 MPa) (725 psi)
The wetted parts are resistant to organic solvents and salt buffers commonly used in chromatography of biomolecules
$2,195.00

GE Healthcare Frac-950 Fraction Collector Unit 13
GE Healthcare Frac-950 Fraction Collector Unit 13
Frac-950 is an automatic fraction collector for use as part of AKTA systems
Flow Rate: 0.001-100 ml/min
Capacity Rack A: 120 tubes (18 mm), 8 tubes (30 mm)
Advanced functionality for both standard and preparative mode that allows large volume fraction collection
Flexible fraction collection from 96-well microplates plates to 250 ml bottles or funnels connected to any vessel
$1,595.00

GE Pharmacia Biotech pH/C-900 AKTA HPLC 18-1107-76 Monitor with Probe Holder
GE Pharmacia Biotech pH/C-900 AKTA HPLC 18-1107-76 Monitor with Probe Holder
Detector type: pH and conductivity
Flow Range: 100 ml/min
Accuracy: The greater of +/-2% of full scale or +/-10 uS/cm in the range 1 uS/cm-300 mS/cm +/-0.1 pH unit, temperature compensat
Response Time: Max. 10 s (0-95% of step) (pH measurements), 3 s (0-95% of step) (Conductivity measurement)
Operating Pressure: Max. 50 bar (5 MPa) (725 psi)
$695.00

GE Pharmacia Biotech pHC-900 AKTA HPLC 18-1107-76 Monitor w/ Conductivity Cell
GE Pharmacia Biotech pHC-900 AKTA HPLC 18-1107-76 Monitor w/ Conductivity Cell
Detector type: pH and conductivity
Flow Range: 100 ml./min
Accuracy: The greater of ± 2% of full scale or ± 10 µS/cm in the range
Response Time: Max. 10 s (0–95% of step) (pH measurements), 3 s (0–95% of step) (Conductivity measurement)
Operating Pressure: Max 50 bar (5 MPa) (725 psi)
$295.00

Amersham Pharmacia AKTA Explorer 100 Liquid Chromatography FPLC System for Parts SOLDOUTAmersham Pharmacia AKTA Explorer 100 Liquid Chromatography FPLC System for Parts SOLDOUT

GE AKTA Explorer 100 FPLC Flash Purification Pred. to Avant Unit5 SOLDOUTGE AKTA Explorer 100 FPLC Flash Purification Pred. to Avant Unit5 SOLDOUT
GE AKTA Explorer 100 FPLC Flash Purification Pred. to Avant Unit5 SOLDOUT
P-900 pump Flow rate : 0.01-100ml per minute
UV/vis - pH - conductivity
Software: Unicorn version 5.11
Fraction collector: Frac-950
Accessories: P-960 sample pump, M-925 mixer, 2ml mixing chamber, Conductivity sensor, Two switch valves, 120 tube fraction rack

GE AKTA explorer 100 Air Flash Purification FPLC Pred. to Avant SOLDOUTGE AKTA explorer 100 Air Flash Purification FPLC Pred. to Avant SOLDOUT
GE AKTA explorer 100 Air Flash Purification FPLC Pred. to Avant SOLDOUT
P-900 pump flow rate : 0.01-100ml per minute
UV/vis - pH - conductivity
Software: Unicorn version 5.11
Fraction collector: GE frac-950
Accessories: P-960 sample pump, M-925 mixer with 2ml mixing chamber, Conductivity sensor, UV sensor, pH sensor, Two switch valve

GE AKTA Explorer 100 Air FPLC Flash Purification Pred Avant SOLDOUTGE AKTA Explorer 100 Air FPLC Flash Purification Pred Avant SOLDOUT
GE AKTA Explorer 100 Air FPLC Flash Purification Pred Avant SOLDOUT
P-900 pump flow rate: 0.01-100ml per minute
UV/vis - pH - conductivity
Software: Unicorn version 5.11
Fraction collector: GE frac-950
Accessories: P-960 sample pump, M-925 mixer w/ 5ml mixing chamber, Conductivity sensor, UV sensor, pH sensor, Two switch valves

GE AKTA Explorer 100 Air FPLC Pred. Avant SOLDOUTGE AKTA Explorer 100 Air FPLC Pred. Avant SOLDOUT
GE AKTA Explorer 100 Air FPLC Pred. Avant SOLDOUT
P-900 pump flow rate: 0.01-100ml per minute
UV/vis - pH - conductivity
Software: Unicorn version 5.11
Fraction collector: GE Frac-950
Accessories: P-960 sample pump, M-925 mixer w/ 2ml mixing chamber. Conductivity sensor, UV sensor, pH sensor, Two switch valves

GE AKTA Explorer 100 Flash Purification FPLC Pred. to Avant SOLDOUTGE AKTA Explorer 100 Flash Purification FPLC Pred. to Avant SOLDOUT
GE AKTA Explorer 100 Flash Purification FPLC Pred. to Avant SOLDOUT
P-900 pump Flow rate: 0.01-100ml per minute
UV/vis - pH - conductivity
Software: Unicorn version 5.11
Fraction collector: Frac-950
Accessories: P-960 sample pump, M-925 mixer w/2ml mixing chamber, Conductivity sensor, Two switch valves (3 ports), 120 tube fra

GE AKTA Explorer 100 FPLC Flash Purification Air Pred. to Avant SOLDOUTGE AKTA Explorer 100 FPLC Flash Purification Air Pred. to Avant SOLDOUT
GE AKTA Explorer 100 FPLC Flash Purification Air Pred. to Avant SOLDOUT
P-900 pump flow rate : 0.01-100ml per minute
UV/vis - pH - conductivity
Software: Unicorn version 5.11
Fraction collector: GE Frac-950
Accessories: P-960 sample pump, M-925 mixer with 2ml mixing chamber, Conductivity sensor, UV sensor, pH sensor, Two switch valve

GE AKTA Explorer 100 FPLC Flash Purification Liquid Chromatography Pred Avant SOLDOUTGE AKTA Explorer 100 FPLC Flash Purification Liquid Chromatography Pred Avant SOLDOUT
GE AKTA Explorer 100 FPLC Flash Purification Liquid Chromatography Pred Avant SOLDOUT
P-900 pump Flow rate : 0.01-100ml per minute
Detectors: UV/vis - PH - conductivity - Airflow
Software: Unicorn version 5.11
Fraction collector: Frac-950
Accessories: Air-900 detector , IV-908 motor valve, INV-907 motor valve, PV-908 motor valves, M-925 Mixer w/ 12ml chamber

GE AKTA Explorer 100 FPLC Flash Purification Pred. to Avant SOLDOUTGE AKTA Explorer 100 FPLC Flash Purification Pred. to Avant SOLDOUT
GE AKTA Explorer 100 FPLC Flash Purification Pred. to Avant SOLDOUT
Application: Purification of microgram to gram quantities of protein
Operating Pressure: Max. 10 MPa (1450 psi)
Detection: UV Absorbance, pH, and Conductivity
Fraction collection: Frac-950

GE AKTA EXPLORER 100 FPLC Flash Purification Pred. to Avant SOLDOUTGE AKTA EXPLORER 100 FPLC Flash Purification Pred. to Avant SOLDOUT
GE AKTA EXPLORER 100 FPLC Flash Purification Pred. to Avant SOLDOUT
P-900 pump flow rate: 0.01-100ml per minute
UV/vis - pH - conductivity
Software: Unicorn version 5.11
Fraction collector: Frac-950
Accessories: P-960 sample pump, M-925 mixer w/ 2ml mixing chamber, Conductivity sensor, Two switch valves (3 ports), 120 tube fr

GE AKTA Explorer 100 FPLC Flash Purification Pred. to Avant SOLDOUTGE AKTA Explorer 100 FPLC Flash Purification Pred. to Avant SOLDOUT
GE AKTA Explorer 100 FPLC Flash Purification Pred. to Avant SOLDOUT
P-900 pump Flow rate: 0.01-100ml per minute
UV/Vis - pH - conductivity (no pH probe)
Software: Unicorn version 5.11
Fraction collector: Frac-950
Accessories: P-950 sample pump, M-925 mixer, 2ml mixing chamber, Conductivity sensor, (2) switch valves (3 ports), 120 tube frac

GE AKTA Explorer 100 FPLC Flash Purification Pred. to Avant SOLDOUTGE AKTA Explorer 100 FPLC Flash Purification Pred. to Avant SOLDOUT
GE AKTA Explorer 100 FPLC Flash Purification Pred. to Avant SOLDOUT
Application: Purification of microgram to gram quantities of protein
Operating Pressure: Max. 10 MPa (1450 psi)
Detection: UV Absorbance, pH, and Conductivity
Fraction collection: Frac-950

GE AKTA Explorer 100 FPLC Flash Purification Pred. to Avant Unit2 SOLDOUTGE AKTA Explorer 100 FPLC Flash Purification Pred. to Avant Unit2 SOLDOUT
GE AKTA Explorer 100 FPLC Flash Purification Pred. to Avant Unit2 SOLDOUT
P-900 pump flow rate: 0.01-100ml per minute
UV/vis - pH - conductivity
Software: Unicorn version 5.11
Fraction collector: Frac-950
Accessories: P-960 sample pump, M-925 mixer w/ 2ml mixing chamber, Conductivity sensor, Two switch valves (3 ports), 120 tube fr

GE AKTA Explorer 100 FPLC Flash Purification Pred. to Avant Unit2 SOLDOUTGE AKTA Explorer 100 FPLC Flash Purification Pred. to Avant Unit2 SOLDOUT
GE AKTA Explorer 100 FPLC Flash Purification Pred. to Avant Unit2 SOLDOUT
P-900 pump Flow rate: 0.01-100ml per minute
UV/Vis - pH - Conductivity
Software: Unicorn version 5.11
Fraction collector: Frac-950
Accessories: P-960 sample pump, M-925 mixer, 2ml mixing chamber, Conductivity sensor(2) switch valves, 120 tube fraction rack

GE AKTA Explorer 100 FPLC Pred Avant SOLDOUTGE AKTA Explorer 100 FPLC Pred Avant SOLDOUT
GE AKTA Explorer 100 FPLC Pred Avant SOLDOUT
P-900 pump flow rate : 0.01-100ml per minute
UV/vis - pH - conductivity
Software: Unicorn version 5.11
Fraction collector: GE Frac-950
Accessories: P-960 sample pump, M-925 mixer w/ 12ml mixing chamber, Conductivity sensor, UV sensor, PH sensor

GE AKTA Explorer 100 FPLC Pred Avant Unit#2 SOLDOUTGE AKTA Explorer 100 FPLC Pred Avant Unit#2 SOLDOUT
GE AKTA Explorer 100 FPLC Pred Avant Unit#2 SOLDOUT
P-900 pump flow rate: 0.01-100ml per minute
UV/vis - pH - conductivity
Software: Unicorn version 5.11
Fraction collector: GE Frac-950
Accessories: P-960 sample pump, M-925 mixer w/ 2ml mixing chamber, Conductivity sensor, UV sensor, pH sensor, Two switch valves

GE AKTA Explorer 100 FPLC Pred. to Avant SOLDOUTGE AKTA Explorer 100 FPLC Pred. to Avant SOLDOUT
GE AKTA Explorer 100 FPLC Pred. to Avant SOLDOUT
Application: Purification of microgram to gram quantities of protein
Operating Pressure: Max. 10 MPa (1450 psi), P-900 Pump Flow rate: 0.01-100ml per minute
Detectors: UV/vis, pH, Conductivity, Airflow
Fraction collector: Frac-950
Accessories : Air-900 detector, IV-908 motor valve, INV-907 motor valve, PV-908 motor valves, 3-port valves