GE Amersham pH/C-900 Monitor AKTA FPLC 18-1107-76 Conductivity Detector 5MPa
GE Amersham pH/C-900 Monitor AKTA FPLC 18-1107-76 Conductivity Detector 5MPa
Detector type: pH and conductivity
Accuracy: The greater of +/- 2% of full scale or +/- 10 uS/cm in the range 1 uS/cm-300 mS/cm +/- 0.1 pH unit, temperature compen
Flow Range: 100 ml./min
Response Time: Max. 10 s (0–95% of step) (pH measurements), Max. 3 s (0–95% of step) (Conductivity measurement)
Operating Pressure: Max. 50 bar (5 MPa) (725 psi)
$1,245.00

GE Amersham pH/C-900 Monitor AKTA FPLC 18-1107-76 Conductivity Detector Unit2
GE Amersham pH/C-900 Monitor AKTA FPLC 18-1107-76 Conductivity Detector Unit2
Detector type: pH and conductivity
Flow Range: 100 ml./min
Accuracy: The greater of ± 2% of full scale or ± 10 µS/cm in the range 1 µS/cm-300 mS/cm ± 0.1 pH unit, temperature compensated,
Response Time: Max. 10 s (0–95% of step) (pH measurements), Max. 3 s (0–95% of step) (Conductivity measurement)
Operating Pressure: Max. 50 bar (5 MPa) (725 psi)
$1,495.00

Gilson PREP ELS II 2 ELSD Evaporative Light Scattering Detector - System 1
Gilson PREP ELS II 2 ELSD Evaporative Light Scattering Detector - System 1
Thermo-Split Technology precisely controls temperature of spray chamber and drift tube separately
Output Signal0 – 10mV DC or 0 – 5V DC, dependent on full-scale and calibration settings
Light Source670 nM laser diode, < 5 mW
Liquid Contact Materials include Stainless steel, glass, anodized aluminum and Teflon®
$825.00

Shimadzu SPD-20A UV/VIS Detector HPLC Prominence SPD20A LC 228-45003-32
Shimadzu SPD-20A UV/VIS Detector HPLC Prominence SPD20A LC 228-45003-32
Detector Type: UV/VIS Detection
Cell temperature-control range: 5C above room temperature to 50C
Light source: Deuterium (D2) lamp
Wavelength range: 190 to 700 nm
Wavelength accuracy: 1 nm max
$4,995.00

Agilent 1100 Variable Wavelength Detector G1314A VWD HPLC Liquid Chromatography SOLDOUTAgilent 1100 Variable Wavelength Detector G1314A VWD HPLC Liquid Chromatography SOLDOUT
Agilent 1100 Variable Wavelength Detector G1314A VWD HPLC Liquid Chromatography SOLDOUT
Detector type: VWD
Standard: 14-ul volume, 10-mm cell path length and 40 bar (588 psi) pressure maximum
Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, one output
Wavelength range 190–600 nm
Chromatography Type: HPLC

Antec Decade II 2 SCC 171.0035 Electrochemical Detector ECD for HPCL Waters 2465 SOLDOUTAntec Decade II 2 SCC 171.0035 Electrochemical Detector ECD for HPCL Waters 2465 SOLDOUT
Antec Decade II 2 SCC 171.0035 Electrochemical Detector ECD for HPCL Waters 2465 SOLDOUT
Electrochemical Detector
2 Channel
Auto, DC, Pulse, Scan Modes
UPLC, HPLC or LC
Column/flowcell oven

Antec Decade II 2 TCC 171.0039 Electrochemical Detector ECD for HPLC Waters 2465 SOLDOUTAntec Decade II 2 TCC 171.0039 Electrochemical Detector ECD for HPLC Waters 2465 SOLDOUT
Antec Decade II 2 TCC 171.0039 Electrochemical Detector ECD for HPLC Waters 2465 SOLDOUT
Electrochemical Detector
3 channel
Auto, DC, Pulse, and Scan modes
UPLC, HPLC or LC
C2V Contol Valve

CTC LC PAL Leap Autosampler with CoolStack, Wash Station, Supply Bottles, Valve SOLDOUTCTC LC PAL Leap Autosampler with CoolStack, Wash Station, Supply Bottles, Valve SOLDOUT
CTC LC PAL Leap Autosampler with CoolStack, Wash Station, Supply Bottles, Valve SOLDOUT
Chromatography type - HPLC A
Sample Size - 1 to 50ul per sample with current setup A
Injection Method - 6 position valve box for up to 5,000psi injections A
Sample Storage - Coolstack with external digital controller A

Gilson PREP ELS II 2 ELSD Evaporative Light Scattering Detector SOLDOUTGilson PREP ELS II 2 ELSD Evaporative Light Scattering Detector SOLDOUT
Gilson PREP ELS II 2 ELSD Evaporative Light Scattering Detector SOLDOUT
Thermo-Split Technology precisely controls temperature of spray chamber and drift tube separately
Output Signal0 – 10mV DC or 0 – 5V DC, dependent on full-scale and calibration settings
Light Source670 nM laser diode, < 5 mW
Liquid Contact Materials include Stainless steel, glass, anodized aluminum and Teflon®

Gilson UV/VIS 151 Detector SOLDOUTGilson UV/VIS 151 Detector SOLDOUT

Gilson UV/VIS 155 Detector SOLDOUTGilson UV/VIS 155 Detector SOLDOUT

Polymer Laboratories PL-ELS 1000 Evaporative Light Scattering Detector ELSD SOLDOUTPolymer Laboratories PL-ELS 1000 Evaporative Light Scattering Detector ELSD SOLDOUT

Sedere / Schimadzu Sedex 75 ELSD Evaporative Light Scattering Detector SOLDOUTSedere / Schimadzu Sedex 75 ELSD Evaporative Light Scattering Detector SOLDOUT

Shimadzu ELSD LT-II / Sedere Sedex 85 Light Scattering Device - New Bulb SOLDOUTShimadzu ELSD LT-II / Sedere Sedex 85 Light Scattering Device - New Bulb SOLDOUT

Shimadzu LT II ELSD / Sedere Sedex 85 LT-ELSD / Agilent 1200 ELSD 85001 SOLDOUTShimadzu LT II ELSD / Sedere Sedex 85 LT-ELSD / Agilent 1200 ELSD 85001 SOLDOUT
Shimadzu LT II ELSD / Sedere Sedex 85 LT-ELSD / Agilent 1200 ELSD 85001 SOLDOUT
Evaporative Light Scattering Detector
Flow range 200 uL to 2.5 mL
Sensitivity: < 1ng caffeine (LOD)
Light Source: Selected High Efficiency Blue LED (470nm)
Detector High Sensitivity Photomultiplier

Teledyne Isco ELSD 340CF Preparative Light Scatering Detector CombiFlash RF SOLDOUTTeledyne Isco ELSD 340CF Preparative Light Scatering Detector CombiFlash RF SOLDOUT
Teledyne Isco ELSD 340CF Preparative Light Scatering Detector CombiFlash RF SOLDOUT
ELSD (Evaporating Light Scattering Detector)
5 mL/min to 1 L/min
Light source 670 nm Laser Diode, < 5 mW
HPLC,LC and flash

Tested - Sedere SEDEX 75 ELSD Evaporative Light Scattering Detector SOLDOUTTested - Sedere SEDEX 75 ELSD Evaporative Light Scattering Detector SOLDOUT
Tested - Sedere SEDEX 75 ELSD Evaporative Light Scattering Detector SOLDOUT
Evaporative Light Scattering Detector
Flow Rate 0.1 to 5 mL/min
Signal Drift Less than 1 mV/hr
Light Source Polychromatic Tungsten Halogen Lamp
Detector High Sensitivity Photomultiplier

Tested Agilent 1100 Diode Array Detector G1315B DAD HPLC Liquid Chromatography SOLDOUTTested Agilent 1100 Diode Array Detector G1315B DAD HPLC Liquid Chromatography SOLDOUT
Tested Agilent 1100 Diode Array Detector G1315B DAD HPLC Liquid Chromatography SOLDOUT
Detector type: DAD
Standard: 13 ul volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
Analog outputs Recorder/integrator: 100 mV or 1 V, output range0.001 – 2 AU, two outputs
Wavelength range: 190 – 950 nm, Linear absorbance range > 2 AU (upper limit)
Chromatography Type: HPLC

Tested, New Bulb - HP Agilent 1100 Series G1315A Diode Array Detector DAD SOLDOUTTested, New Bulb - HP Agilent 1100 Series G1315A Diode Array Detector DAD SOLDOUT

Thermo Electron Finnigan Surveyor PDA Plus Detector HPLC - SRVYR-PDA1P SOLDOUTThermo Electron Finnigan Surveyor PDA Plus Detector HPLC - SRVYR-PDA1P SOLDOUT
Thermo Electron Finnigan Surveyor PDA Plus Detector HPLC - SRVYR-PDA1P SOLDOUT
Detector Type: UV/Vis detector
Flow Cell: 50 mm LightPipe flow cell
Absorbance range: 0.0005 to +3.0 AUFS
Spectral Range: 190nm to 800
Light source: Deuterium and tungsten lamps