Categories

GE Biacore 4000 SPR Surface Plasmon Resonance Analyzer Pred X100/T200

Brand:GE Biacore
Product Code: 13944
Availability: 1
Price: $59,995.00
Qty:        

Ask a question about this product


GE Biacore 4000 SPR Surface Plasmon Resonance Analyzer Pred X100/T200


Send

GE Biacore 4000 SPR Surface Plasmon Resonance Analyzer Pred X100/T200 | Priced $59,995.00 | bostonind.com (13944)

Here is a GE Biacore 4000 SPR Surface Plasmon Resonance Analyzer Pred X100/T200

Made in 2015
New costs about $650,000

Predecessor to:
N/A

Condition:
This GE Biacore 4000 SPR Surface Plasmon Resonance Analyzer is in good working order and also has very good cosmetic condition.

PLEASE READ
During an on-site visit from the GE's field service engineer this system's all individual components were tested for proper function and found to be in good working order. Please see list of test steps below that GE performed.

Howewer GE engineer noted that there was an intermittent issue while running a full system check, the system's communication with the software would interrupt resulting in reinitialization.
GE specified that the fix for this would be to replace CPU PCB into the system. This would be the only repair required, the cost for the board is $12,000.00 (PCB Control Unit Biacore 4000, P/N BR100439)

Aside from intermittent communication system is fully functional. GE engineer continued to run direct commands and found there to be nothing additional to note during the visit.

We would recommend PM and 1 year service agreement when you placing system in service. You can expect investment of around $50-65K which will give you a system that is fully PMed and comes with a 1 Year warranty just like the new one. If you decide to get PM and board replacement only it should be around $27,000.


Please see the exact video and photos below.

Testing we performed:
The GE Biacore 4000 SPR Surface Plasmon Resonance Analyzer was found to pass functionality testing:
Tested flush: PASSED
Tested prime: PASSED
Tested rinse: PASSED
Tested Standby: PASSED
Tested shutdown: PASSED
Tested needle replacement/positioning: PASSED
Tested Interior light: PASSED
SYSTEM SELF CHECK: PASSED
Tested internal timer on autosampler PCB: PASSED
Tested pulse generation on autosampler PCB: PASSED
Tested photo interrupters: PASSED
Tested communication with dispenser pump: PASSED
Tested recalibrate dispenser pump: PASSED
Tested filling dispenser pump: PASSED
Tested margin to photo interrupter: PASSED
Tested photo interrupter: PASSED
Tested communication with buffer pump: PASSED
Tested buffer pump fill: PASSED
Tested buffer pump empty: PASSED
Tested communication with optical unit PCB: PASSED
Tested communication with LED control PCB: PASSED
Tested communication with display PCB: PASSED
Tested communication with docking PCB: PASSED
Tested communication with peltier drive PCB: PASSED
Tested communication with temp. signal converter PCB: PASSED
Tested communication with valve control PCB: PASSED
Tested communication with pressure control PCB: PASSED

System consists of:
GE Biacore 4000 SPR Surface Plasmon Resonance Analyzer
Rolling Table
Julabo Model F25 Chiller Circulator
(10) Microplate/Reservoir Tray
(10) 1000ul Buffer bottles
2000ul Buffer bottle
Waste Bottle
Windows 7 Desktop running Biacore 4000 Control software ver1.1
Windows 7 Desktop running Oracle 12c Server
Communication and power cables.

Configuration and Setup:
Sample Handling: automated sample loading and injection
Association rate (k) (proteins): 10^3 to 10^9 M^-1 s^-1, Dissociation rate (kd): 5 Ã- 10^-5 to 1s^-1
Concentration range: 2 pM to 2 mM
Sample Volume (kinetics): 28 to 376 uL
Sample Capacity: antibodies: 10 x 96, LMW: 6 x 384

Applications: Kinetics/affinity characterization, kinetics/affinity screening, LMW interaction analysis, fragment screening, epitope mapping, immunogenicity, concentration analysis
Affinity range: fM to mM
Precision (concentration analysis): <5% CV
Molecular weight limit: > Mr 50
Baseline noise: < 0.1 RU (RMS)
Baseline drift: < 0.3 RU/min in ambient temperature range 15C to 35C
Immobilized molecule consumption: 3 to 10 ug/spot
Analysis temperature: 4C to 40C
Sample storage temperature: 4C to 40C
Data collection rate: 1 or 10 Hz
Number of flow cells: 4 x 5 spots
Unattended run time: 60 h
Data evaluation time: 120 curve sets < 6 min
GxP Support: Yes (included)
Additional Packages: antibody extension, LMW extension

Up to 4000 interactions/24 hours. [direct binding assay, 4 targets per flow cell, cycle time 5 minutes]
LMW compound screening: 1200 samples/24 hours
Antibody screening: 960 samples/24 hours
Kinetic characterization: 240 determinations/24 hours [4 targets per flow cell]

Main applications include: Fragment and LMW compound screening, Antibody and antibody fragment screening and characterization, Compound hit validation and hit to lead characterization and lead optimization of compounds.

Typical data evaluation time: Screening <1 hour, Kinetics 1 to 2 hours

Video Description:
The video begins with a full GE Biacore 4000 SPR Surface Plasmon Resonance Analyzer view. The camera pans around the instrument to show sides and front.
The camera then pans to the computer where the control software is started. Once started the system achieves communication with the software and begins to initialize.
Next with the GE Biacore 4000 SPR Surface Plasmon Resonance Analyzer in a ready state - a Normalization method is started. The demonstration continues to show the system eject a sample tray.
Next the system is test and sees that there is no other trays loaded. The sample tray is then reloaded into the system and the program begins its run.
The camera continues to pan around to show function of the syringe pumps and condition of the GE Biacore 4000 SPR Surface Plasmon Resonance Analyzer system.
Once the method is complete the camera pans back to show a final full GE Biacore 4000 SPR Surface Plasmon Resonance Analyzer system view.

Documentation:
Datasheet: https://drive.google.com/file/d/1vQEWTjSnquIMxfPd6e4ZLV1epr4vfTEU/view?usp=sharing

Accessories Brochure: https://drive.google.com/file/d/1x-5Kp3-GWFdnlRgHKPS4JWMUQPh9LBQw/view?usp=sharing

Manual: N/A

Assay Handbook: https://drive.google.com/file/d/1XU1-LPu27gYtDv3sPfIIUWdWVocb2X_G/view?usp=sharing

GE Customer Service Report: https://drive.google.com/file/d/0Bz5srQzgsa6uQnlZdDJXU1dUZEtiYXVUSjZXVkRabVRWVkR3/view?usp=sharing

This will ship via freight. Please contact us with your zip code to obtain shipping quote.

Please do not hesitate to contact us if you have any questions.

 photo 13944- 2.jpg photo 13944- 6.jpg photo 13944- 9.jpg photo 13944- 12.jpg photo 13944- 14.jpg photo 13944- 15.jpg photo 13944- 19.jpg photo 13944- 20.jpg photo 13944- 21.jpg photo 13944- 22.jpg photo 13944- 24.jpg photo 13944- 26.jpg photo 13944- 28.jpg photo 13944- 31.jpg photo 13944- 32.jpg photo 13944- 34.jpg photo 13944- 35.jpg photo 13944- 37.jpg photo 13944- 39.jpg photo 13944- 40.jpg photo 13944- 41.jpg photo 13944- 42.jpg photo 13944- 43.jpg photo 13944- 44.jpg photo 13944- 45.jpg photo 13944- 46.jpg photo 13944- 47.jpg photo 13944- 48.jpg photo 13944- 49.jpg photo 13944- 50.jpg

 


GE Biacore 4000 SPR Surface Plasmon Resonance Analyzer Pred X100/T200

Manufacturer Description and Specification:

Manufacturer Documentation:

Boston Industries, Inc. © 2019