Approved Vendor to many US, Canada, and EU Universities | |
International Shipping | |
Customer References Available | |
Training and Installation Options Available |
- Stock: In Stock
- Brand: Agilent
- Product Code: 51129
- Condition: Pre-Owned
For Sale Agilent 1260 Infinity II Bio-Inert LC System
(Needs Bio-Inert Quaternary Pump G5654A and Bio-Inert Multisampler G5668A to be complete system)
- Fully Functional
- Serviced & in Stock
- Current Model
- Good cosmetic condition
- Technical sales consultation available
- WARRANTY
Here is what you will receive:
- Agilent 1260 Infinity II Multiple Wavelength Detector (MWD) p/n: G7165A with bio-inert standard flow cell, with RFID tag, 10 mm, 13 uL, 120 bar p/n: G5615-60022
- Agilent 1260 Infinity II Multicolumn Thermostat p/n: G7116A
- Agilent 1290 Infinity Thermostat module for Fraction Collector p/n: G1330B
- Agilent 1260 Infinity II Bio-inert Fraction Collector p/n: G5664B
- 1x Fraction Collector Tray for 215 test tubes, 12mm OD, max tube height: 48mm p/n: G1364-84536
- 1x 4-Plates tray, cooled p/n: G1364-60621
- Solvent bottle tray
- Power and communication cables
Please Note: The computer and or OpenLab CD software and proper licenses for final configuration should be purchased separately from Agilent. They are not included.
(Needs Bio-Inert Quaternary Pump G5654A and Bio-Inert Multisampler G5668A to be complete system)
Agilent 1260 Infinity ll LC System Configuration:
Agilent 1260 Infinity II Multiple Wavelength Detector:
- Detection type: 1024-element photodiode array
- Number of signals: 8
- Maximum data rate: 120 Hz
- Short-term signal noise (ASTM): < ± 0.7·10-5 AU at 254 nm and 750 nm
- Drift: < 0.9·10-3 AU/h at 254 nm
- Linear absorbance range: > 2 AU (5 %) at 265 nm
- Wavelength range: 190 – 950 nm
- Wavelength accuracy: ± 1 nm,
- Wavelength bunching: 1 – 400 nm
- Slit width: 1, 2, 4 , 8, 16 nm
- Diode width: < 1 nm
- Time programmable: wavelength, polarity, peak width, lamp bandwidth, auto balance, wavelength range, threshold, spectra storage mode
- Flow cell: standard bio-inert: 13 uL volume, 10 mm cell path length and 120 bar pressure maximum
Agilent 1260 Infinity II Multicolumn Thermostat:
- Operating principle: thermostatted column compartment with dual, independent Peltier-element. Solvent pre-heating and still-air operation for reduction of chromatographic band-broadening under UGPC conditions.
- Temperature range: 10 DegC below ambient (minimum 4 DegC) to 85 DegC
- Temperature range increment: settable in steps of 0.1 DegC
- Temperature stability ±0.1 DegC
- Temperature accuracy ±0.5 DegC (with calibration at 40 DegC)
- Temperature precision 0.05 DegC
- Independent temperature zones: 2 in single device
- Column capacity: 4 columns of up to 300 mm length plus InfinityLab Quick Connect fittings or pre-column.
- Heat-up/cool-down time: 5 min from ambient to 40 DegC; 10 min from 40 DegC to 20 DegC; 25 min from 25 DegC to 85 DegC
- Weight: 12.5 kg (27.6 lbs)
- Dimensions: (H×W×D): 16 x 43.5 x 43.6 cm. (6.3 x 17.1 x 17.2 in.)
- Power requirements: 100 – 240 V~, ± 10 % 50/60 Hz, ± 5 %, 150 VA, 150 W
Agilent 1290 Infinity Thermostat Module:
- Temperature range: settable from 4DegC to 40DegC in 1DegC increments
- Temperature accuracy at ambient temperatures < 25DegC and humidity <50%: 3 DegC to 8 DegC at a setpoint of 4 DegC
- Temperature accuracy at ambient temperatures <30 DegC and humidity <60%: 3 DegC to 9 DegC at a setpoint of 4 DegC
Agilent 1260 Infinity II Bio-inert Fraction Collector:
- Plates/trays: 4 x well-plates full tray (only one type of well-plates can be used at a time in one tray); full tray with 215 test tubes (12 mm OD, max. height 48 mm, ~8 mL / tube)
- Delay Volume: fraction collector inlet to diverter valve: ~50 ul; diverter valve: ~15 ul; diverter valve to needle: ~10 ul; needle: ~4 ul
- Maximum system flow: 10 mL/min
- Maximum collection volume: up to 20 mL
- Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector
- Cooling: thermostat module p/n: G1330B included, performance depending on ambient conditions and the volume of collected fractions
- Trigger modes: time slices, peak, timetable
- Trigger Source: G7165A, 1260 Infinity II MWD
- Operating Modes: discrete fractions, continuous flow, needle into location, droplet setup mode
- Maximum time to move between neighboring vessels: movement in x-direction: < 0.15 s.; movement in y-direction: < 0.3 s
- Diverter valve: 3/2 valve, switching time: < 100 ms
- Maximum pressure: 6 bar at the diverter valve during switching
Customization/Options:
- Other detectors and flow cell options might be available. Please inquire with our sales team.
Testing performed by our in-house service team:
Agilent 1260 Infinity II Multiple Wavelength Detector:
- We performed the initialization test.
- We conducted the software communication test.
- We conducted the cell test.
- We performed the dark current test to verify baseline stability.
- We conducted the filter test to check optical filter performance.
- We carried out the holmium oxide test to verify wavelength accuracy.
- We performed the intensity test to ensure appropriate signal strength.
- We conducted the slit test to check for proper light dispersion.
- We verified the wavelength accuracy with the wavelength verification test.
- We performed the noise and drift test to ensure signal stability over time.
Agilent 1260 Infinity II Multicolumn Thermostat:
- We ensure the successful initialization of the system.
- We verify the communication functionality with the control software.
- We assess the efficiency and reliability of the cooling and heating functionality.
Agilent 1290 Infinity Thermostat Module:
- We performed the initialization test to verify proper startup.
- We conducted the software communication test to verify seamless integration with the system.
- We carried out the cooling test to verify efficient temperature regulation.
Agilent 1260 Infinity II Bio-inert Fraction Collector:
- We performed the initialization test.
- We verified seamless communication with the software.
- We verified the sample rack detection to ensure correct identification.
- We tested the arm movement to confirm precise positioning.
- We checked the collection of the sample to validate accurate fraction collection.
Instrument Overview:
- The Agilent 1260 Infinity II Bio-Inert LC System is designed for high-performance liquid chromatography (HPLC).
- It features biocompatible materials to prevent sample contamination and ensure accurate results.
- This LC system offers high resolution and sensitivity for reliable analysis.
- We recommend a quaternary pump and multisampler for flexibility and efficiency.
- The Agilent 1260 Infinity II Bio-Inert LC System supports a wide range of flow rates and pressures.
Instrument Application:
- Analysis of biomolecules such as proteins, peptides, and nucleic acids.
- Separation and quantification of monoclonal antibodies and biosimilars.
- Characterization of complex biological samples in pharmaceutical research.
- Quality control in the production of biotherapeutics.
- Analysis of metabolites and other small molecules in clinical research.
- Purity testing of biocompatible materials and drug formulations.
The Key Features:
- The Biocompatible flow path prevents sample contamination and degradation.
- The Recommended high-performance quaternary pump supports a wide range of solvents and flow rates.
- Temperature-controlled column compartment for consistent separation conditions.
- Compatible with a wide range of detectors for versatile application needs.
Additional technical info:
- Brochure: Agilent 1260 Infinity ll LC System Brochure
- Manual: Agilent 1260 Infinity II Multiple Wavelength Detector Manual
- Manual: Agilent 1290 Infinity Thermostat Manual
- Manual: Agilent 1260 Infinity II Bio-inert Fraction Collector Manual
- Manual: Agilent 1260 Infinity II Multicolumn Thermostat Manual
Video Overview:
About us
How we pack
Why do so many customers choose to order from us?
- We have experience servicing and repairing these instruments.
- This instrument goes through all the described service steps before shipping. see questions section below
- We offer detailed photos and videos of the instruments you buy.
- We are an approved pre-owned equipment vendor to many large US, Canadian, and EU Universities.
- We are an approved pre-owned equipment vendor to many Fortune 500 US and International Biopharma companies.
- Technical sales consultation available
- Remote installation and instrument operation training may be available.
- On-site installation may be available in the Boston Area (New England area)
- US or International shipping is no problem (see the shipping tab on how we pack and feel at ease)
- Warranty
- An extended warranty may be available
- You get after-sales technical support
- Customer references are available
- The instrument will be fully functional!
- Smooth process from the initial quote to order fulfillment
This will ship via freight. Please contact us with your zip code to obtain a shipping quote.
COMMON QUESTIONS AND ANSWERS BELOW
What are the steps you take to verify, service, and confirm the functionality of the Agilent 1260 Infinity ll LC System?
We verify various instrument functions individually and together, performing necessary repairs or maintenance to bring the instrument to our quality standards..
Agilent 1260 Infinity II Multiple Wavelength Detector:
- We performed the initialization test.
- We conducted the software communication test.
- We conducted the cell test.
- We performed the dark current test to verify baseline stability.
- We conducted the filter test to check optical filter performance.
- We carried out the holmium oxide test to verify wavelength accuracy.
- We performed the intensity test to ensure appropriate signal strength.
- We conducted the slit test to check for proper light dispersion.
- We verified the wavelength accuracy with the wavelength verification test.
- We performed the noise and drift test to ensure signal stability over time.
Agilent 1260 Infinity II Multicolumn Thermostat:
- We ensure the successful initialization of the system.
- We verify the communication functionality with the control software.
- We assess the efficiency and reliability of the cooling and heating functionality.
Agilent 1290 Infinity Thermostat Module:
- We performed the initialization test to verify proper startup.
- We conducted the software communication test to verify seamless integration with the system.
- We carried out the cooling test to verify efficient temperature regulation.
Agilent 1260 Infinity II Bio-inert Fraction Collector:
- We performed the initialization test.
- We verified seamless communication with the software.
- We verified the sample rack detection to ensure correct identification.
- We tested the arm movement to confirm precise positioning.
- We checked the collection of the sample to validate accurate fraction collection.
What supplies do I need?
You will need the consumables starting out:
- Glass Test Tubes (agilent.com)
- Fraction Collector Supplies for HPLC (agilent.com)
- Quick Change Valves (agilent.com)
- Bio-Inert Autosampler, 1260 Infinity II Bio-Inert Multisampler | Agilent
- 1260 Infinity II Bio-Inert Pump - Ordering | Agilent
Can I view the Agilent 1260 Infinity ll LC System in person at your facility or do a live Zoom demo before it is shipped to me?
We invite you to visit our facility for an on-site demo, or feel free to request a virtual Zoom demo of the instrument you are interested in.
What about the warranty? Installation, training, maintenance?
Warranty Terms:
- The instrument comes fully warrantied for both parts and labor.
- The customer should retain all packing materials during the warranty period.
What should I watch out for when buying a Agilent 1260 Infinity ll LC System used/pre-owned from another lab?
- Make sure the instrument is properly packed for shipping and will arrive safely. If the instrument is large, request to have it packed in a wooden crate.
- Confirm that there is no physical damage or any misaligned internal components.
- Ask what accessories are included.
- Ask how long the warranty is and what it covers.
Here is what our technical team tests so you can request something similar and ensure your instrument will be fully functional.
Agilent 1260 Infinity II Multiple Wavelength Detector:
- We performed the initialization test.
- We conducted the software communication test.
- We conducted the cell test.
- We performed the dark current test to verify baseline stability.
- We conducted the filter test to check optical filter performance.
- We carried out the holmium oxide test to verify wavelength accuracy.
- We performed the intensity test to ensure appropriate signal strength.
- We conducted the slit test to check for proper light dispersion.
- We verified the wavelength accuracy with the wavelength verification test.
- We performed the noise and drift test to ensure signal stability over time.
Agilent 1260 Infinity II Multicolumn Thermostat:
- We ensure the successful initialization of the system.
- We verify the communication functionality with the control software.
- We assess the efficiency and reliability of the cooling and heating functionality.
Agilent 1290 Infinity Thermostat Module:
- We performed the initialization test to verify proper startup.
- We conducted the software communication test to verify seamless integration with the system.
- We carried out the cooling test to verify efficient temperature regulation.
Agilent 1260 Infinity II Bio-inert Fraction Collector:
- We performed the initialization test.
- We verified seamless communication with the software.
- We verified the sample rack detection to ensure correct identification.
- We tested the arm movement to confirm precise positioning.
- We checked the collection of the sample to validate accurate fraction collection.
We recommend inspecting the instrument in person or requesting a virtual demo; this will allow you to evaluate the condition and performance of the instrument you are considering purchasing.
Do you have a Agilent 1260 Infinity ll LC System on hand?
- This is a common model, and we generally stock multiple instruments, accessories, and many replacement parts to back up our warranty.
I found it elsewhere for less. What goes into your price?
We acknowledge that sometimes you can purchase this model instrument elsewhere, possibly for less.
Here are some of the reasons for our price.
- We may offer longer warranty terms.
- We cover shipping costs during the warranty period. (Customer is required to save packing materials for the duration).
- We have to have technical staff that can do the testing/repairs and after-sales support if there are any issues.
- We invest considerable time into the testing and service of each instrument we sell.
- We have to purchase various testing supplies (often expensive) to perform testing.
- We have to purchase any missing required accessories to make the instruments complete.
- We have to procure and stock service parts to support our warranty.
- We have extensive experience packing sensitive instruments. See the shipping section in the website menu for info on how not to pack.
- We guarantee that the instrument will be functional.
This procurement is for a University or College. Are purchase orders with NET terms accepted?
- If you are a US or Canadian customer, we are likely already a registered vendor in your University's vendor system. This would greatly expedite the process of PO approvals and get this instrument into your lab faster.
- POs are accepted from US and Canadian universities.
How fast will you ship?
- We can ship within a few days to two weeks. Shipping time depends on the current demand for our instruments. Members of our sales team will be able to offer current delivery estimates.
Will my instrument be insured during shipping?
- All instruments shipped within the USA and internationally are fully insured. This applies as long as we are the shipper and handle shipping arrangements.
- If the buyer handles shipping, then shipping insurance responsibility falls to the buyer; we highly advise that the buyer obtain shipping insurance from their carrier.
How do you pack? Have you packed and shipped Agilent 1260 Infinity ll LC System Instruments in the past? Do you ship Internationally?
Packing
- Most larger instruments ship in fully enclosed ISPM15-certified wooden crates with proper padding underneath, and the sides have moving components braced.
- Accessories are packed safely in boxes with padding and then safely packed inside the crate.
- We may not use a crate for local deliveries to save you money *if delivered by us.
- We often use “tilt’ & “shock” indicators on the crates to ensure the crate has not been excessively tilted and dropped where equipment may suffer damage.
- Photos are taken during the packing process to make sure nothing is missed.
USA/Canada Shipping
- Within the US and Canada, we will ship via selected freight carriers. We do not use low-price/high-damage carriers as we want the equipment to get safely to you.
International Shipping
- Internationally, we will only ship via Air Freight or Air Parcel (such as UPS or DHL), which provides reliability, no exposure to Ocean weather, and timely delivery.
We have extensive experience packing and shipping fragile instruments globally.
Our experience and process
- We have safely packed and shipped thousands of sensitive analytical instruments.
How much will I save buying it pre-owned, and is it worth it?
A lot…and it is undoubtedly worth it, and here is why. Feel free to ask for feedback from hundreds of customers who bought from us.
- You will pay less than half vs. buying a new instrument. Why not spend leftover funds on another instrument for your lab?
- You will get our standard warranty, plus, when available, an option to obtain an extended warranty agreement.
- Know that your instrument was tested and working the day it left our facility and is covered if there are faults.
- Get extra peace of mind by adding an extended warranty or service agreement when such an option is available.
Sustainability
- Well, this one is easy: buying a pre-owned instrument is great for the planet; you are reducing unnecessary waste, CO2 output, and water use that would be used during the manufacturing process.
I have more questions; I want to receive a formal quote.
Absolutely! Please give us a call (1-617-397-3486) or complete this form to get your questions answered or receive a formal Quote.