Menu
Your Cart

Mass Spectrometers

Brand: Teledyne Isco Product Code: 42663
Mass Range: 50 to 1200 Dalton
Resolution: 1 Dalton
Ion Source: ESI (Electrospray Ionization)
Compatibility: CombiFlash RF+ Lumen, CombiFlash RF+ 200i, CombiFlash EZPrep, CombiFlash NextGen, AccqPrep
Software: PeakTrak
$14,995.00
Brand: Advion Product Code: 50924
Mass Spec Source: APCI (Atmospheric Pressure Chemical Ionization Source)
Flow rate range: Flash separation at 10–100 mL/min
Acquisition modes: Positive and negative ionization in parallel
Detection range (m/z): 10–2000
Detection accuracy: ±0.1 m/z
$12,995.00
Brand: Waters Product Code: 44124
Mass Range: 2 to 2048 m/z
Scan Speed: up to 10,000 Da/s
Mass Stability: mass drift is <0.1 Da over a 24 hour period
Detector Low-noise, off-axis, long-life photomultiplier detector
Acquisition Modes: Full scan, MS Product ion scan, Precursor ion scan, Constant neutral loss scan, Selected ion recording (SIR), Multiple reaction monitoring (MRM), Simultaneous full scan, and MRM (RADAR)
Brand: Waters Product Code: 44933
Interactive diagnostics software for worry-free system and fluidics optimization and performance checks with IntelliStart Technology
1 pg sensitivity with either ESI or APCI
10,000 Da/sec scan speeds up to 2,000 Da for full compatibility with seconds-wide fast LC peaks
Simple upkeep and minimal bench space requirements
Dual orthogonal sampling ionization with ZSpray source
Brand: Thermo Product Code: 25464
Resolution: 60000 (FWHM) @ m/z 400 with a scan repetition rate of 1 second; Minimum resolution 7500 @ m/z 400; Maximum resolution 100000 @ m/z 400
Cycle Time: 1 scan at 60000 resolution @ m/z 400 per second
Mass Range: m/z 50 - 2000 or m/z 200 - 4000
Mass Accuracy: <5 ppm with external calibration <2 ppm with internal calibration
Dynamic Range: >10000 between mass spectra >4000 between highest and lowest detectable mass in one spectrum
Brand: Thermo Scientific Product Code: 41483
Detector Type: "Orbitrap" Fourier transform detector
Scan Rate: 1-10 Hz
Mass Accuracy: <5ppm with external calibration <2ppm with internal standard and lock masses
Source: Thermo Scientific API source with ESI probe
Mass Range: 50 - 4000 m/z
Brand: LECO Product Code: 50796
Ion Sources: Standard EI (Electron Ionization) and the Optional MMS (Multi-Mode Source)
GC system: Agilent 8890 w/ L-PAL3 autosampler
Spectral Acquisition Rate: 1 to 200 spectra/second in full mass range
Ion Detection Mode: Positive and Negative
Linear Dynamic Range: ≥ 5 orders in 1D EI mode; ≥ 4 orders in 2D EI mode
Brand: Advion Product Code: 47195
Mass Range: 10-1,200 m/z
Acquisition Speed: 10,000 m/z units/sec
Sensitivity(ESI): 10 pg reserpine (FIA - 5 uL injection at 100 uL/min) 100:1 S/N (RMS) with SIM of m/z 609.3
Accuracy: +/- 0.1 m/z units of the entire acquisition range
Stability: 0.1 m/z units @ 1,200 m/z, over 12 hour period @ operating temperature of 20C +/-1C
Brand: Advion Product Code: 25697
Mass Range: 10-2,000 m/z
Acquisition Speed: 10,000 m/z units/sec
Sensitivity(ESI): 10 pg reserpine (FIA - 5 uL injection at 100 uL/min) 100:1 S/N (RMS) with SIM of m/z 609.3
Accuracy: +/- 0.1 m/z units of the entire acquisition range
Stability: 0.1 m/z units @ 1,200 m/z, over 12 hour period @ operating temperature of 20C +/-1C
Showing 1 to 9 of 9 (1 Pages)