Throughput (tubes/hr): Re-array only: 500; Re-array and 1D or 2D Decode: 300; Re-array, 2D Decode and Weigh: 170 Compatible with all ANSI/SLAS and custom racks and tubes and vials 200uL - 20mL, up to 125 mm tall Barcode readers decode 1D and 2D barcodes on the base and side of tubes and vials Power Requirements: 100-240VAC 60Hz Dimensions: 45in x 28in x 35in (115cm x 72cm x 89cm)
Ideal for high throughput applications 96 separate channel nozzles in an 8 x 12 microtiter plate standard pattern Pipetting head can be moved along a vertical (z) and a horizontal (x) axis for whole-plate pipetting Two plate holders, each with two working positions, move in a horizontal (y) axis and allow a maximum of three different plates with SBS footprint to be used simultaneously Adjustable feet at each corner of the base and under each tip loading position allow you to operate Liquidator 96 in a perfectly level position
Plate Positions: 3 Plate Formats: 96- and 384-well plates (use shifting plate) Dimensions: (W x D x H): 42 cm x 30 cm x 54 cm (17” x 12“ x 21“) Weight: 27.7 kg (61.1 lbs) Power Requirements: 100 to 240 VAC, 50 to 60 Hz
Plate Positions: 2 Plate Formats: 96- and 384-well plates (use shifting plate) Dimensions: (W x D x H): 42 cm x 30 cm x 54 cm (17” x 12“ x 21“) Weight: 27.7 kg (61.1 lbs) Power Requirements: 100 to 240 VAC, 50 to 60 Hz
Plate Positions: 3 Plate Formats: 96- and 384-well plates (use shifting plate) Dimensions: (W x D x H): 42 cm x 30 cm x 54 cm (17” x 12“ x 21“) Weight: 27.7 kg (61.1 lbs) Power Requirements: 100 to 240 VAC, 50 to 60 Hz
Plate Positions: 3 Plate Formats: 96- and 384-well plates (use shifting plate) Dimensions: (W x D x H): 42 cm x 30 cm x 54 cm (17” x 12“ x 21“) Weight: 27.7 kg (61.1 lbs) Power Requirements: 100 to 240 VAC, 50 to 60 Hz
Plate Positions: 3 Plate Formats: 96 and 384 (use shifting plate) well plates Dimensions: (W x D x H): 42 cm x 30 cm x 54 cm (17” x 12“ x 21“) Weight: 27.7 kg (61.1 lbs) Power Requirements: 100 to 240 VAC, 50 to 60 Hz
Plate Positions: 2 Plate Formats: 96 and 384 (use shifting plate) well plates Dimensions: (W x D x H): 42 cm x 30 cm x 54 cm (17” x 12“ x 21“) Weight: 25.7 kg (56.7 lbs) Power Requirements: 100 to 240 VAC, 50 to 60 Hz
Plate Positions: 3 Plate Formats: 96 and 384 (use shifting plate) well plates Dimensions: (W x D x H): 42 cm x 30 cm x 54 cm (17” x 12“ x 21“) Weight: 27.7 kg (61.1 lbs) Power Requirements: 100 to 240 VAC, 50 to 60 Hz
Plate Positions: 3 Plate Formats: 384 Dimensions: (W x D x H): 42 cm x 30 cm x 54 cm (17” x 12“ x 21“) Weight: 27.7 kg (61.1 lbs) Power Requirements: 100 to 240 VAC, 50 to 60 Hz
Sampler Type: X/Y/Z with stationary rack design Probe Positioning Performance: Accuracy: +/- 0.75 mm in X/Y/Z dimensions, Repeatability: +/- 0.20 mm in X/Y/Z dimensions Probe Rinse: Probe rinsing and flowing probe rinsing occurs through a dedicated rinse station Plate ?apacity: Code 20 series tray insert - up to five racks Software Control: Computer control via Ethernet; or via RS-232 or GSIOC
Volume: 0.1 to 250ul Increments: 0.1ul Dispense Speed: Low (40ul/s), Medium (120ul/s) and High (180ul/s) Functions: Prime, Pipetting, Sample Dilution, Repeat Dispensing, Reverse Pipetting, and Serial Dilution Saveable run programs