Brand: Beckman Coulter Product Code: 52018
Robotic Arms: Span-8 w/ Gripper
Channels: 8
Volume: 1-1000uL
Disposable Tips: P20, P30, P30XL, P250, P1000
Application: liquid handling and sample preparation
$19,995.00
Brand: Beckman Coulter Product Code: 44798
Max Capacity Volume Range: up to - 9L (8L with current rotor)
Maximum Speed: 10,000 RPM (5,000 RPM with current rotor)
Maximum g-Force: 17100g
Temperature Range: from -10C to +40C
Timed Run: 1 min to 99 hrs, 59 mins (timed run); Total centrifuge effect (g-seconds) or Continuous hold
$18,995.00
Brand: Beckman Coulter Product Code: 49439
Aperture Size: 10uM - 2,000 uM (Nominal diameter)
Number of Channels: Pulse data is digitized and can be processed to achieve up to 400 size channels for a selected pulse range. Number of channels and range can be reprocessed as necessary
Electrolyte Solutions: All aqueous and non-aqueous electrolyte solutions recommended for use with aperture technology will be suitable for use.
Aperture Current Range: 30uA - 6000uA in 0.2uA steps
Aperture Current Accuracy: +/-0.4% of setting
$17,995.00
Brand: Beckman Coulter Product Code: SM100032-VIXR
Cell Density Range: 5x10^4 to 1x10^7 cells/mL
Cell Viability Method: Trypan blue dye exclusion method
Counting Accuracy: +/- 10%
Effective Resolution: 1 um per pixel
Minimum Sample Volume: 500 uL
$6,895.00
Brand: Beckman Coulter Product Code: SM100032-VIXR2
Cell Density Range: 5x10^4 to 1x10^7 cells/mL
Cell Viability Method: Trypan blue dye exclusion method
Counting Accuracy: +/- 10%
Effective Resolution: 1 um per pixel
Effective Resolution: 1 um per pixel
$6,895.00
Brand: Beckman Coulter Product Code: 56005
Maximum RPM: 25,000 RPM
Rotor Type: Fixed-Angle (High Performance)
Max g-Force: 75,600.00
k-Factor: 418
Nominal Capacity: 400 mL
$3,995.00
Brand: Beckman Coulter Product Code: 41592
Maximum Capacity: 6 x 1000mL
Max RPM/Max G-Force: 4,200 / 5,020
Fits Centrifuges: J6-M, J-HC
Rotor Insert/Accessories: see manual attached
$2,995.00
Brand: Beckman Coulter Product Code: 44588
Maximum Capacity: 6 x 1000mL
Max RPM/Max G-Force: 4,200 / 5,020
Fits Centrifuges: J6-MI, J-HC
Rotor Insert/Accessories: see manual attached
$2,995.00
Brand: Beckman Coulter Product Code: 32010
Max. RPM / Max. g: 80,000 / 444,000
No. of Tubes x Nominal Tube Volume (mL): 8 x 8
Nominal Rotor Capacity (mL): 64
k Factor: 29
For Use in: Optima MAX, Optima MAX-E
$2,195.00
Brand: Beckman Coulter Product Code: 44278
Buffer Tray: 2 x 36mL CESI vials, 4 x 25mL trays
Current Range: 3 to 300uA programmable at 0.1uA Increments
Pressure Range: -5 to +100psi
Sample Tray: 2 x 96-well plates, 2 x 48 2mL vials, 2 x 48 0.5mL vials, 2 x 48 PCR vials
Voltage Range: 1 - 30kV (1 - 10kV for injections), Programmable in 0.1kV increments, Reversible voltage programmed through user interface
Brand: Beckman Coulter Product Code: 30872
Cell Density Range: 5x10^4 to 1x10^7 cells/mL
Cell Viability Method: 2-70 um
Counting Accuracy: +/- 10%
Effective Resolution: 1 um per pixel
Minimum Sample Volume: 500 uL
Brand: Beckman Coulter Product Code: 31891
Cell Density Range: 5x10^4 to 1x10^7 cells/mL
Cell Viability Method: 2-70 um
Counting Accuracy: +/- 10%
Effective Resolution: 1 um per pixel
Minimum Sample Volume: 500 uL
Brand: Beckman Coulter Product Code: 31892
Cell Density Range: 5x10^4 to 1x10^7 cells/mL
Cell Viability Method: 2-70 um
Counting Accuracy: +/- 10%
Effective Resolution: 1 um per pixel
Minimum Sample Volume: 500 uL
Brand: Beckman Coulter Product Code: 30413
Cell Density Range: 5x10^4 to 1x10^7 cells/mL
Cell Viability Method: 2-70 um
Counting Accuracy: +/- 10%
Effective Resolution: 1 um per pixel
Minimum Sample Volume: 500 uL
Brand: Beckman Coulter Product Code: 31319
Cell Density Range: 5x10^4 to 1x10^7 cells/mL
Cell Viability Method: 2-70 um
Counting Accuracy: +/- 10%
Effective Resolution: 1 um per pixel
Minimum Sample Volume: 500 uL
Brand: Beckman Coulter Product Code: 30250
Cell Density Range: 5x10^4 to 1x10^7 cells/mL
Cell Viability Method: 2-70 um
Counting Accuracy: +/- 10%
Effective Resolution: 1 um per pixel
Minimum Sample Volume: 500 uL
Brand: Beckman Coulter Product Code: 26541
Cell Density Range: 5x10^4 to 1x10^7 cells/mL
Cell Viability Method: 2-70 um
Counting Accuracy: +/- 10%
Effective Resolution: 1 um per pixel
Minimum Sample Volume: 500 uL
Brand: Beckman Coulter Product Code: 50573
Cell density range: 5x10^4 to 1.5x10^7 cells/mL
Cell Viability Method: Trypan blue dye exclusion method
Counting Accuracy: +/- 10%
Effective Resolution: 0.5 um per pixel
Minimum sample volume: 200 uL in normal Mode, 170 uL in fast Mode
Brand: Beckman Coulter Product Code: 47937
Maximum RPM: 90,000 (current rotor rated for 70,000rpm only)
Temperature Setting: 0 to 40C in 1C increments
Temperature Control (after equilibration): +/-0.5C over entire set temperature range (+/-0.8C over entire set temperature for SW-32 rotor)
Accel. + Decel. Profiles: 10 Acceleration Rates, 11 Deceleration Rates
Integrated Software: Optima XPN-90 Ultracentrifuge v1.1.185
Brand: Beckman Coulter Product Code: 46344
Maximum Capacity: 162 mL
Max RPM: 100,000RPM (50,000RPM with current rotor installed)
Temp Range: 0 to 40C
Rotor Model: 50Ti Fixed Angle
Brand: Beckman Coulter Product Code: 30305
Aperture: 100um
Range: 2-80um Total, 2-60um Standard, 60-80um Extended
Aperture Range: Total range: 2% to 80% of aperture diameter
Standard Range: 2% to 60% of aperture diameter. Extended Range: 60% to 80% of aperture diameter
Number of Channels: Pulse data is digitized and can be processed to achieve up to 400 size channels for a selected pulse range
Brand: Beckman Coulter Product Code: 31568
Aperture: 100um
Range: 2-80um Total, 2-60um Standard, 60-80um Extended
Aperture Range: Total range: 2% to 80% of aperture diameter. Standard Range: 2% to 60% of aperture diameter. Extended Range: 60% to 80% of aperture diameter
Number of Channels: Pulse data is digitized and can be processed to achieve up to 400 size channels for a selected pulse range. Number of channels and range can be reprocessed as necessary
Electrolyte Solutions: All aqueous and non-aqueous electrolyte solutions recommended for use with aperture technology will be suitable for use
Brand: Beckman Coulter Product Code: 30308
Aperture: 50um
Range: 1-40um Total, 1-30um Standard, 30-40um Extended
Aperture Range: Total range: 2% to 80% of aperture diameter. Standard Range: 2% to 60% of aperture diameter. Extended Range: 60% to 80% of aperture diameter
Number of Channels: Pulse data is digitized and can be processed to achieve up to 400 size channels for a selected pulse range. Number of channels and range can be reprocessed as necessary
Electrolyte Solutions: All aqueous and non-aqueous electrolyte solutions recommended for use with aperture technology will be suitable for use
Showing 1 to 25 of 55 (3 Pages)