Here is a BD Accuri C6 Flow Cytometer w/ C-Sampler Pred Plus Unit5
Made in 2014
Predecessor to:
Current model is Accuri C6 Plus
Condition:
The BD Accuri C6 Flow Cytometer w/ C-Sampler is in good working order and also has good cosmetic condition.
Please see the exact video and photos below.
Testing we performed:
The BD Accuri C6 Flow Cytometer w/ C-Sampler passed all tests and was found to be fully functional:
Tested power on and initialization: PASSED
Tested communication with software: PASSED
Tested operation of the auto sampler: PASSED
Tested fluidics system: PASSED
Ran several wash and decontamination cycles: PASSED
Ran assays with BioLegends 8 peak rainbow particles: PASSED (Results shown in included photos and video peaks/plots are as expected)
Comes with Maintenance Kit installed.
System consists of:
BD Accuri C6 Flow Cytometer Unit
C Sampler assembly
Reagent bottle hose bundle
Reagent bottle rack w/ sheath, waste, detergent, and FACSclean bottles
BD Accuri 2 month maintenance kit
Desktop PC running BD Accuri C6 software ver1.0 (includes monitor, keyboard, and mouse)
Communication and power cables
Configuration and Setup:
Laser Configuration: 14.7mW 640nm Diode red laser, 20mW 488nm solid state blue laser
Detection Configuration: 4 color - FL1: 530/30nm, FL2: 585/40nm, FL3: 610/20nm, FL4: 675/25nm
Flow Rates: 10-100 uL/min, 5-40 uM core size
Flow Cell: 200um ID quartz capillary
Minimum Detectable Particle Size: 0.5um
Common Compatible Fluorochromes/dyes Per Channel:
FL1: FITC, BD Horizon Brilliant Blue 515, Alexa Fluor 488, CFSE, GFP, YFP
FL2: PE, PI, PE-CF594
FL3: RFP, PI, PE-CF594
FL4: APC, Alexa Fluor 647
Fluorescence Sensitivity, MESF: FITC < 150; PE < 100
Scatter Resolution: Resolves human peripheral blood lymphocytes, monocytes, and granulocytes.
Fluorescence Linearity: 2 +/-0.05% for chicken erythrocyte nuclei (CEN)
Fluorescence Precision: <3% CV for CEN
Flow Rates and Core Sizes:
Slow 14 uL/min, 10 uM core
Medium 35 uL/min, 16 uM core
Fast 66 uL/min, 22 uM core
Custom 10-100 uL/min, 5-40 uM core
Minimum Detectable Particle Size: 0.5um
Minimum Sample Volume: 50uL
Compatible Plate Types: Standard 96-well (flat, round, and v-bottom) plates / deep-well 96-well plates and 48-well plates
Flow Cell: 200um ID quartz capillary
Data Acquisition Rate: 10,000 events/second, maximum
The compact footprint and transportable weight of the BD Accuri C6 Flow Cytometer also make it a valuable personal use tool for experienced researchers who want a cytometer to be easily available when and where they need it.
The BD Accuri C6 Flow Cytometer small enough to easily fit on a bench top and can be placed in a laminar flow hood if biohazard containment is required.
Video Description:
The video gives an overview of the BD Accuri C6 Flow Cytometer system, and also performs functionality.
Documentation:
Datasheet: Optical Filter Guide
Brochure: BD Accuri C6 brochure
Manual: BD Accuri C6 Flow Cytometer Instrument Manual
Manual: BD Accuri CSampler Software User Guide
This will ship via freight. Please contact us with your zip code to obtain shipping quote.
*SM* Small Crate
270#
Please do not hesitate to contact us if you have any questions.